Combined Rastelli procedure with supra-coronary ascending aorta replacement

2020 ◽  
pp. 1-3
Author(s):  
Yatin Arora ◽  
Velayoudam Devagourou ◽  
Tanushree Kar

Abstract We present a 5-year-old child with pulmonary atresia palliated at infancy with midline shunt now for complete repair with aneurysmally dilated aorta. Patient underwent a combined Rastelli procedure with supra-coronary ascending aorta replacement with hemi-arch repair. Patient was discharged on post-operative day 10 and was asymptomatic on follow-up.

2021 ◽  
pp. 021849232110150
Author(s):  
Marco Moscarelli ◽  
Nicola Di Bari ◽  
Giuseppe Nasso ◽  
Khalil Fattouch ◽  
Thanos Athanasiou ◽  
...  

Background We sought to determine if a modified technique for ascending aorta replacement with sinotubular junction reduction and stabilization was safe. Methods This technique was performed by suspension of the three commissures, invagination of the aortic Dacron graft and advancing the graft into the ventricles. We included patients with dilatation of the ascending aorta, normal sinuses of Valsalva dimension (<45 mm), with or without aortic annulus enlargement (>25 mm) and with various degree of aortic insufficiency (from grade 1 to 3). Results From April to October 2019, 20 patients were recruited from two centers; mean age was 66.9 ± 12.8 years, 13 were male; grade 1, 2 and 3 was present in 12, 2 and 6 patients, respectively. All patients underwent ascending aorta replacement with modified technique; an additional open subvalvular ring was used in 8 patients with aortic insufficiency ≥ 2; cusps repair was performed in 6 patients (5 plicating central stitches/1 shaving); concomitant coronary artery bypass grafting was performed in 10 patients. There was no 30-day mortality. One patient was re-explored for bleeding. All patients completed six-month follow-up; at the transthoracic echocardiography, there was no aortic insufficiency ≥ 1 except one patient with aortic insufficiency grade 1 who underwent ascending aorta replacement and subvalvular ring; no patients underwent reintervention. Conclusions This modified technique for ascending aorta replacement and sinotubular junction stabilization was safe. It could be associated with other aortic valve sparing techniques. However, such remodeling approach has to be validated in a larger cohort of patients with longer follow-up.


Author(s):  
Alessandro Verzini ◽  
Marta Bargagna ◽  
Guido Ascione ◽  
Alessandra Sala ◽  
Davide Carino ◽  
...  

Background: Bicuspid aortic valve (BAV) is the most common congenital heart defect and it is responsible for an increased risk of developing aortic valve and ascending aorta complications. In case of mild to moderate BAV disease in patients undergoing supracoronary ascending aorta replacement, it is unclear whether a concomitant aortic valve replacement should be performed. Methods: From June 2002 to January 2020, 75 patients with mild-to-moderate BAV regurgitation (± mild-to-moderate stenosis) who underwent isolated supracoronary ascending aorta replacement were retrospectively analyze. Clinical and echocardiographic follow-up was 100% complete (mean: 7.4±3.9 years, max 16.4). Kaplan Meier estimates were employed to analyze long-term survival. Cumulative incidence function for time to re-operation, recurrence of aortic regurgitation (AR)≥3+ and aortic stenosis (AS) greater than moderate, with death as competing risk, were computed. Results: There was no hospital mortality and no cardiac death occurred. Overall survival at 12 years was 97.4±2.5%, 95% CI [83.16-99.63]. At follow-up there were no cases of aortic root surgery whereas 3 patients underwent AV replacement. At 12 years the CIF of reoperation was 2.6±2.5%, 95% CI [0.20-11.53]. At follow up, AR 3+/4+ was present in 1 pt and AS greater than moderate in 3. At 12 years the CIF of AR>2+/4+ was 5.1±4.98% and of AS>moderate 6.9±3.8%. Conclusions: In our study mild to moderate regurgitation of a BAV did not significantly worse at least up to 10 years after isolated supracoronary ascending aorta replacement.


2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
L C Wang ◽  
Y X Liu ◽  
Y J Dun ◽  
X G Sun

Abstract Background Acute Stanford type A aortic dissection (ATAAD) is the most common catastrophic aortic event. Most ATAAD involves the aortic root which has many important anatomical structures such as aortic valve, so the proper treatment of dissected root can ensure a good prognosis for patients. However, there is still no consensus on root management strategies for ATAAD patients with aortic root involvement. Purpose This clinical study aimed to evaluate the therapeutic effect of modified aortic root repair in ATAAD. Methods From September 2017 to September 2020, Participants with root involvement of ATAAD were recruited who underwent modified aortic root repair as well as some additional procedure such as aortic valve junction suspension plasty based on the aortic sinus tear extent. During this novel procedure, the proximal anastomosis plane was at the level of the sinu-tubular junction and the false lumen below it was retained. We collected and analyzed the perioperative clinical data and follow-up imaging data of patients, and further evaluated the early and mid-term efficacy of this surgical approach. Results A total of 79 patients were enrolled, including 59 males and 20 females, the age was (52.4±11.3) years old (28–73 years), the diameter of aortic sinus was (38.6±4.1) mm, and the diameter of sinu-tubular junction was (41.8±4.8) mm. In this group, 75 patients (94.9%) received ascending aorta replacement, total arch replacement and frozen elephant trunk, 2 patients (2.5%) received ascending aorta replacement and hybrid total arch replacement, 2 patients (2.5%) received ascending aorta replacement and partial arch replacement. Cardiopulmonary bypass time was (197.2±58.6) min (118–455 min), blocking time was (132.6±38.9) min (73–323 min), circulatory arrest time was (10.3±7.0) min (0–27 min). There was no perioperative death, no paraplegia, one secondary thoracotomy, five renal failures needing hemodialysis treatment and two cerebral infarctions. Before patients discharged, aortic CTA showed that the residual false lumen in the sinus disappeared. And the diameter of the aortic sinus was (35.5±3.1) mm, the diameter of the junction of the aortic sinus was (30.0±3.0) mm. The patients were followed up for (18±12) months (3–35 months). There was one patient died during follow-up and no further surgical intervention at the root of the aorta. Follow-up aortic CTA showed no residual or new dissection in the aortic sinus and no significant difference in the diameters of aortic sinu-tubular junction (P=0.122) or aortic sinus (P=0.37) between postoperative period and follow-up period. Echocardiography showed that the structure and function of the aortic valve were normal. Conclusions The modified aortic root repair for ATAAD is relatively simple, easy to learn and safe in perioperative period. Early and mid-term follow-up image examination showed that the structure of aortic sinus returned to normal. The long-term clinical effect requires close attention. FUNDunding Acknowledgement Type of funding sources: None. Modified aortic root repair procedure Aortic root diameter change under CTA


2021 ◽  
Vol 14 (8) ◽  
pp. e242304
Author(s):  
Ivo Spasov Petrov ◽  
Zoran Iovan Stankov ◽  
Damyan Boychev Boychev

We present a case of a persistent false lumen after ascending aorta replacement due to Stanford Type A dissection treated by endovascular means. The main entry tear was occluded with an atrial septal defect closure device, sealing the false lumen. A total of five additional stents were implanted to centralise and secure the flow in the true lumen. CT scan at 6-month follow-up showed excellent results with a decreased total aortic diameter and thrombosed false lumen.


2004 ◽  
Vol 7 (3) ◽  
pp. E201-E207
Author(s):  
Antonio Maria Calafiore ◽  
Michele Di Mauro ◽  
Carlos-A. Mestres ◽  
Gabriele Di Giammarco ◽  
Giovanni Teodori ◽  
...  

2021 ◽  
Vol 14 (4) ◽  
pp. e39-e41
Author(s):  
Masashi Yokoi ◽  
Hiroshi Fujita ◽  
Tatsuhito Ogawa ◽  
Tsuyoshi Ito ◽  
Yoshihiro Seo ◽  
...  

2021 ◽  
pp. 152660282110282
Author(s):  
Juan Shi ◽  
Ligang Liu ◽  
Xiang Wei ◽  
Mingjia Ma

Objectives To investigate the effectiveness of modified stent-grafts (SGs) for the management of ascending aortic pathologies. Materials and Methods From January 2015 to December 2019, 31 individuals were treated by ascending aortic endovascular repair with a back-table modified SG for acute (n=4) or chronic (n=1) type A aortic dissections, penetrating aortic ulcers (n=18), pseudoaneurysms (n=2), anastomotic fistula (n=1), and endoleaks after thoracic endovascular aortic repair (TEVAR) (n=5). The commercially available thoracic aortic SGs were modified with a fenestration or truncation technique on the back-table according to aortography during the operation. Results The 30-day mortality and aorta-related mortality rates were 12.9% and 6.5%, respectively. There were 2 strokes, 3 respiratory insufficiencies, and 6 endoleaks during hospitalization. During a mean follow-up of 28.8±16.6 months, the overall survival rates at 1 year and 3 years were both 80.6%. Free from adverse event rates at 1 year and 3 years were 88.9% and 84.7%, respectively. There were 2 deaths during follow-up: One patient died of cachexia 1 month after discharge, and the other patient died of acute myocardial infarction 3 months after discharge. One patient with a pseudoaneurysm underwent open ascending aorta replacement 3 months after discharge for a type Ia endoleak. Another patient suffered from cerebellar infarction 17 months after discharge. Conclusion The modified SG for endovascular repair of the ascending aorta is a practicable alternative and presents acceptable outcomes in high-risk patients.


2009 ◽  
Vol 23 (3) ◽  
pp. 436-438 ◽  
Author(s):  
Shinju Obara ◽  
Masayuki Nakagawa ◽  
Shinichiro Takahashi ◽  
Masahiko Akatu ◽  
Tsuyoshi Isosu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document