scholarly journals Use of ASD closure device for the sealing of false lumen entry in the ascending aorta after dissection Type A surgical repair

2021 ◽  
Vol 14 (8) ◽  
pp. e242304
Author(s):  
Ivo Spasov Petrov ◽  
Zoran Iovan Stankov ◽  
Damyan Boychev Boychev

We present a case of a persistent false lumen after ascending aorta replacement due to Stanford Type A dissection treated by endovascular means. The main entry tear was occluded with an atrial septal defect closure device, sealing the false lumen. A total of five additional stents were implanted to centralise and secure the flow in the true lumen. CT scan at 6-month follow-up showed excellent results with a decreased total aortic diameter and thrombosed false lumen.

2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
L C Wang ◽  
Y X Liu ◽  
Y J Dun ◽  
X G Sun

Abstract Background Acute Stanford type A aortic dissection (ATAAD) is the most common catastrophic aortic event. Most ATAAD involves the aortic root which has many important anatomical structures such as aortic valve, so the proper treatment of dissected root can ensure a good prognosis for patients. However, there is still no consensus on root management strategies for ATAAD patients with aortic root involvement. Purpose This clinical study aimed to evaluate the therapeutic effect of modified aortic root repair in ATAAD. Methods From September 2017 to September 2020, Participants with root involvement of ATAAD were recruited who underwent modified aortic root repair as well as some additional procedure such as aortic valve junction suspension plasty based on the aortic sinus tear extent. During this novel procedure, the proximal anastomosis plane was at the level of the sinu-tubular junction and the false lumen below it was retained. We collected and analyzed the perioperative clinical data and follow-up imaging data of patients, and further evaluated the early and mid-term efficacy of this surgical approach. Results A total of 79 patients were enrolled, including 59 males and 20 females, the age was (52.4±11.3) years old (28–73 years), the diameter of aortic sinus was (38.6±4.1) mm, and the diameter of sinu-tubular junction was (41.8±4.8) mm. In this group, 75 patients (94.9%) received ascending aorta replacement, total arch replacement and frozen elephant trunk, 2 patients (2.5%) received ascending aorta replacement and hybrid total arch replacement, 2 patients (2.5%) received ascending aorta replacement and partial arch replacement. Cardiopulmonary bypass time was (197.2±58.6) min (118–455 min), blocking time was (132.6±38.9) min (73–323 min), circulatory arrest time was (10.3±7.0) min (0–27 min). There was no perioperative death, no paraplegia, one secondary thoracotomy, five renal failures needing hemodialysis treatment and two cerebral infarctions. Before patients discharged, aortic CTA showed that the residual false lumen in the sinus disappeared. And the diameter of the aortic sinus was (35.5±3.1) mm, the diameter of the junction of the aortic sinus was (30.0±3.0) mm. The patients were followed up for (18±12) months (3–35 months). There was one patient died during follow-up and no further surgical intervention at the root of the aorta. Follow-up aortic CTA showed no residual or new dissection in the aortic sinus and no significant difference in the diameters of aortic sinu-tubular junction (P=0.122) or aortic sinus (P=0.37) between postoperative period and follow-up period. Echocardiography showed that the structure and function of the aortic valve were normal. Conclusions The modified aortic root repair for ATAAD is relatively simple, easy to learn and safe in perioperative period. Early and mid-term follow-up image examination showed that the structure of aortic sinus returned to normal. The long-term clinical effect requires close attention. FUNDunding Acknowledgement Type of funding sources: None. Modified aortic root repair procedure Aortic root diameter change under CTA


2021 ◽  
pp. 152660282098527
Author(s):  
Jan Stana ◽  
Carlota Fernandes Prendes ◽  
Ramin Banafsche ◽  
Nikolaos Konstantinou ◽  
Barbara Rantner ◽  
...  

Purpose: To demonstrate the feasibility of urgent endovascular treatment of a chronic type A dissection and contained rupture of the false lumen using a noncustomized triple-branched arch endograft, which necessitated reassignment of the branches to the supra-aortic vessels. Case Report:: A 57-year-old patient with a contained rupture of the descending thoracic aorta, in the setting of a chronic type A dissection and a maximum aortic diameter of 85 mm, was converted to endovascular repair after failure of an open surgical approach. A custom-made triple-branched arch endograft designed for another patient was employed, with concomitant occlusion of the false lumen using a Candy Plug occluder. To adjust the graft’s configuration to the patient’s anatomy, the supra-aortic vessels were not assigned to the originally planned branches. The 12-month follow-up angiography demonstrated a satisfactory result. Conclusion: A noncustomized triple-branched arch endograft can be used in an emergency setting to treat chronic type A dissection, reassigning the branches to the supra-aortic vessels as needed.


2021 ◽  
pp. 021849232110150
Author(s):  
Marco Moscarelli ◽  
Nicola Di Bari ◽  
Giuseppe Nasso ◽  
Khalil Fattouch ◽  
Thanos Athanasiou ◽  
...  

Background We sought to determine if a modified technique for ascending aorta replacement with sinotubular junction reduction and stabilization was safe. Methods This technique was performed by suspension of the three commissures, invagination of the aortic Dacron graft and advancing the graft into the ventricles. We included patients with dilatation of the ascending aorta, normal sinuses of Valsalva dimension (<45 mm), with or without aortic annulus enlargement (>25 mm) and with various degree of aortic insufficiency (from grade 1 to 3). Results From April to October 2019, 20 patients were recruited from two centers; mean age was 66.9 ± 12.8 years, 13 were male; grade 1, 2 and 3 was present in 12, 2 and 6 patients, respectively. All patients underwent ascending aorta replacement with modified technique; an additional open subvalvular ring was used in 8 patients with aortic insufficiency ≥ 2; cusps repair was performed in 6 patients (5 plicating central stitches/1 shaving); concomitant coronary artery bypass grafting was performed in 10 patients. There was no 30-day mortality. One patient was re-explored for bleeding. All patients completed six-month follow-up; at the transthoracic echocardiography, there was no aortic insufficiency ≥ 1 except one patient with aortic insufficiency grade 1 who underwent ascending aorta replacement and subvalvular ring; no patients underwent reintervention. Conclusions This modified technique for ascending aorta replacement and sinotubular junction stabilization was safe. It could be associated with other aortic valve sparing techniques. However, such remodeling approach has to be validated in a larger cohort of patients with longer follow-up.


Author(s):  
Meisam Mokhtari ◽  
Zahra Khajali ◽  
Mona Heidarali ◽  
Majid Haghjoo

Atrial fibrillation (AF) is the most commonly treated arrhythmia in clinical practice and is often found in association with an atrial septal defect (ASD). However, ASD closure rarely confers complete arrhythmia control. A 23-year-old man presented to our center with frequent episodes of palpitations. AF was documented in 12-lead electrocardiography, and echocardiography showed a secundum-type ASD, 14 mm in size, with a significant left-to-right shunt. ASD closure was performed successfully with an ASD occluder device with no residual shunting. During follow-up, the patient experienced several episodes of AF. Thirteen months after the ASD closure, cryoballoon pulmonary vein isolation was done successfully with no complications. During a 12-month follow-up, he had no symptoms or AF recurrences, and echocardiography showed no residual shunting. This study showed that cryoballoon pulmonary vein isolation could be performed successfully without residual shunts in patients with ASD closure devices.


Author(s):  
Alessandro Verzini ◽  
Marta Bargagna ◽  
Guido Ascione ◽  
Alessandra Sala ◽  
Davide Carino ◽  
...  

Background: Bicuspid aortic valve (BAV) is the most common congenital heart defect and it is responsible for an increased risk of developing aortic valve and ascending aorta complications. In case of mild to moderate BAV disease in patients undergoing supracoronary ascending aorta replacement, it is unclear whether a concomitant aortic valve replacement should be performed. Methods: From June 2002 to January 2020, 75 patients with mild-to-moderate BAV regurgitation (± mild-to-moderate stenosis) who underwent isolated supracoronary ascending aorta replacement were retrospectively analyze. Clinical and echocardiographic follow-up was 100% complete (mean: 7.4±3.9 years, max 16.4). Kaplan Meier estimates were employed to analyze long-term survival. Cumulative incidence function for time to re-operation, recurrence of aortic regurgitation (AR)≥3+ and aortic stenosis (AS) greater than moderate, with death as competing risk, were computed. Results: There was no hospital mortality and no cardiac death occurred. Overall survival at 12 years was 97.4±2.5%, 95% CI [83.16-99.63]. At follow-up there were no cases of aortic root surgery whereas 3 patients underwent AV replacement. At 12 years the CIF of reoperation was 2.6±2.5%, 95% CI [0.20-11.53]. At follow up, AR 3+/4+ was present in 1 pt and AS greater than moderate in 3. At 12 years the CIF of AR>2+/4+ was 5.1±4.98% and of AS>moderate 6.9±3.8%. Conclusions: In our study mild to moderate regurgitation of a BAV did not significantly worse at least up to 10 years after isolated supracoronary ascending aorta replacement.


Author(s):  
Piergiorgio Tozzi ◽  
Ziyad Gunga ◽  
Lars Niclauss ◽  
Dominique Delay ◽  
Aurelian Roumy ◽  
...  

Abstract OBJECTIVES Current guidelines recommend prophylactic replacement of the ascending aorta at an aneurysmal diameter of &gt;55 mm to prevent acute Type A aortic dissection (TAAD) in non-Marfan patients. Several publications have challenged this threshold, suggesting that surgery should be performed in smaller aneurysms to prevent this devastating disease. We reviewed our experience with measuring aortic size at the time of TAAD to validate the existing recommendation for prophylactic ascending aorta replacement. METHODS All patients who had been admitted for TAAD to our emergency department from 2014 to 2019 and underwent ascending aorta replacement were included. Marfan patients were excluded. The maximum diameter of the dissected aorta was measured preoperatively using CT scan. We estimated the aortic diameter at the time of dissection to be 7 mm smaller than the measured maximum diameter of the dissected aorta (modelled pre-dissection diameter). RESULTS Overall, 102 patients were included. Of these, 67 were male (65.6%) and 35 were female (34.4%), and the cohort’s mean age was 65 ± 12.1 years. In addition, 66% were treated for arterial hypertension. The mean maximum modelled pre-dissection diameter was 39.6 ± 4.8 mm: 39.1 ± 5.1 mm in men and 40.7 ± 2.8 mm in women (P = 0.1). The cumulative 30-day mortality rate was 19.6% (20/102). CONCLUSIONS TAAD occurred at a modelled aortic diameter below 45 mm in 87.7% of our patients. Therefore, the current aortic diameter threshold of 55 mm excludes ∼99% of patients with TAAD from prophylactic replacement of the ascending aorta. The maximum diameter of the ascending aorta warrants reappraisal and this parameter should be a distinct part of a personalized decision-making process that also takes into account age, gender and body surface area to establish the surgical indication for preventive aorta replacement aimed to improve the survival benefit of this procedure.


2003 ◽  
Vol 75 (6) ◽  
pp. 1785-1790 ◽  
Author(s):  
Kay-Hyun Park ◽  
Kiick Sung ◽  
Kwhanmien Kim ◽  
Tae-Gook Jun ◽  
Young Tak Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document