Optimization of Near-Infrared Spectroscopic Process Monitoring at Low Signal-to-Noise Ratio

2011 ◽  
Vol 83 (6) ◽  
pp. 2172-2178 ◽  
Author(s):  
Hendrik Schneider ◽  
Gabriele Reich
1999 ◽  
Vol 45 (9) ◽  
pp. 1621-1627 ◽  
Author(s):  
Jason J Burmeister ◽  
Mark A Arnold

Abstract Six putative measurement sites were evaluated for noninvasive sensing of blood glucose by first-overtone near-infrared spectroscopy. The cheek, lower lip, upper lip, nasal septum, tongue, and webbing tissue between the thumb and forefinger were examined. These sites were evaluated on the basis of their chemical and physical properties as they pertain to the noninvasive measurement of glucose. Critical features included the effective optical pathlength of aqueous material within the tissue and the percentage of body fat within the optical path. Aqueous optical paths of 5 mm are required to measure clinically relevant concentrations of glucose in the first-overtone region. All of the tested sites met this requirement. The percentage of body fat affects the signal-to-noise ratio of the measurement and must be minimized for reliable glucose sensing. The webbing tissue contains a considerable amount of fat tissue and is clearly the worse measurement site. All other sites possess substantially less fat, with the least amount of fat in tongue tissue. For this reason, the tongue provides spectra with the highest signal-to-noise ratio and is, therefore, the site of choice on the basis of spectral quality.


The Analyst ◽  
2016 ◽  
Vol 141 (12) ◽  
pp. 3601-3620 ◽  
Author(s):  
Chengli Wang ◽  
Xiaomin Li ◽  
Fan Zhang

Upconversion nanoparticles (UCNPs), which can emit ultraviolet/visible (UV/Vis) light under near-infrared (NIR) excitation, are regarded as a new generation of nanoprobes because of their unique optical properties, including a virtually zero auto-fluorescence background for the improved signal-to-noise ratio, narrow emission bandwidths and high resistance to photo-bleaching.


Micromachines ◽  
2020 ◽  
Vol 11 (6) ◽  
pp. 556
Author(s):  
Yuri Yoshida ◽  
Takumi Kawana ◽  
Eiichi Hoshino ◽  
Yasuyo Minagawa ◽  
Norihisa Miki

We demonstrate capture of event-related potentials (ERPs) using candle-like dry microneedle electrodes (CMEs). CMEs can record an electroencephalogram (EEG) even from hairy areas without any skin preparation, unlike conventional wet electrodes. In our previous research, we experimentally verified that CMEs can measure the spontaneous potential of EEG from the hairy occipital region without preparation with a signal-to-noise ratio as good as that of the conventional wet electrodes which require skin preparation. However, these results were based on frequency-based signals, which are relatively robust compared to noise contamination, and whether CMEs are sufficiently sensitive to capture finer signals remained unclear. Here, we first experimentally verified that CMEs can extract ERPs as good as conventional wet electrodes without preparation. In the auditory oddball tasks using pure tones, P300, which represent ERPs, was extracted with a signal-to-noise ratio as good as that of conventional wet electrodes. CMEs successfully captured perceptual activities. Then, we attempted to investigate cerebral cognitive activity using ERPs. In processing the vowel and prosody in auditory stimuli such as /itta/, /itte/, and /itta?/, laterality was observed that originated from the locations responsible for the process in near-infrared spectroscopy (NIRS) and magnetoencephalography experiments. We simultaneously measured ERPs with CMEs and NIRS in the oddball tasks using the three words. Laterality appeared in NIRS for six of 10 participants, although laterality was not clearly shown in the results, suggesting that EEGs have a limitation of poor spatial resolution. On the other hand, successful capturing of MMN and P300 using CMEs that do not require skin preparation may be readily applicable for real-time applications of human perceptual activities.


1989 ◽  
Vol 107 ◽  
pp. 245-255
Author(s):  
Jocelyn Tomkin

AbstractThe usefulness of high signal-to-noise-ratio spectra for both radial-velocity and abundance studies of Algol systems is emphasised. It is shown that division by a hot star is a worthwhile step in pursuit of this objective. A preliminary analysis of high signal-to-noise-ratio, red and near-infrared, Reticon observations of R CMa shows that its primary has solar CNO abundances within the 0.3 dex observational error. The low-mass (0.17 m⊙) secondary of this Algol system must have lost a large fraction of its original mass. Some of this material would have been extensively processed during the secondary’s main-sequence lifetime and would therefore have had a highly non-solar CNO-abundance distribution. The lack of serious contamination of the primary’s abundances is consistent with most, but not all, plausible mass-transfer scenarios.


A double-pass Sisam spectrometer of simplified design is described in which the two gratings rotate about a common axis. Sample spectra are given and the performance of the instrument is assessed and compared with that predicted theoretically. A resolution of 0.05 cm -1 has been achieved at 1.6 µm, corresponding to 90% of the maximum theoretically attainable with the gratings and configuration used. This performance was maintained over a continuously scanned spectral range of 500 cm -1 without realignment of the optical components. The instrument thus offers a real gain in signal-to-noise ratio over the equivalent, practical slit spectrometer of a factor of between 30 and 1000.


2019 ◽  
Author(s):  
Alexander V. Rodin ◽  
Dmitry V. Churbanov ◽  
Sergei G. Zenevich ◽  
Artem Yu. Klimchuk ◽  
Vladimir M. Semenov ◽  
...  

Abstract. We propose a new technique of remote wind measurements based on Doppler analysis of a CO2 absorption line in the 1.605 μm overtone band measured in the direct Sun observation geometry. Heterodyne spectroradiometric measurements of the solar radiation passed through the atmosphere provides an unprecedented spectral resolution up to λ/δλ ~ 107–108 with a signal-to-noise ratio more than 100. The shape of the individual rotational line profile provides unambiguous relationship between offset from the line centre and altitude where a respective part of the line profile is formed. Therefore, an inverse problem may be posed in order to retrieve vertical distribution of wind, with retrievals vertical resolution compromised by a spectral resolution and signal-to-noise ratio of the measurements. A close coincidence between measured and synthetic absorption line is reached, with retrieved wind profile between the surface and 50 km being in a good agreement with reanalysis models. This method may pose an alternative to widely employed lidar and radar techniques.


Sign in / Sign up

Export Citation Format

Share Document