Ring-Oven Based Preconcentration Technique for Microanalysis: Simultaneous Determination of Na, Fe, and Cu in Fuel Ethanol by Laser Induced Breakdown Spectroscopy

2013 ◽  
Vol 85 (3) ◽  
pp. 1547-1554 ◽  
Author(s):  
Juliana Cortez ◽  
Celio Pasquini
Soil Systems ◽  
2019 ◽  
Vol 3 (4) ◽  
pp. 66 ◽  
Author(s):  
Xuebin Xu ◽  
Changwen Du ◽  
Fei Ma ◽  
Yazhen Shen ◽  
Jianmin Zhou

Accurate management of soil nutrients and fast and simultaneous acquisition of soil properties are crucial in the development of sustainable agriculture. However, the conventional methods of soil analysis are generally labor-intensive, environmentally unfriendly, as well as time- and cost-consuming. Laser-induced breakdown spectroscopy (LIBS) is a “superstar” technique that has yielded outstanding results in the elemental analysis of a wide range of materials. However, its application for analysis of farmland soil faces the challenges of matrix effects, lack of large-scale soil samples with distinct origin and nature, and problems with simultaneous determination of multiple soil properties. Therefore, LIBS technique, in combination with partial least squares regression (PLSR), was applied to simultaneously determinate soil pH, cation exchange capacity (CEC), soil organic matter (SOM), total nitrogen (TN), total phosphorus (TP), total potassium (TK), available phosphorus (AP), and available potassium (AK) in 200 soils from different farmlands in China. The prediction performances of full spectra and characteristic lines were evaluated and compared. Based on full spectra, the estimates of pH, CEC, SOM, TN, and TK achieved excellent prediction abilities with the residual prediction deviation (RPDV) values > 2.0 and the estimate of TP featured good performance with RPDV value of 1.993. However, using characteristic lines only improved the predicted accuracy of SOM, but reduced the prediction accuracies of TN, TP, and TK. In addition, soil AP and AK were predicted poorly with RPDV values of < 1.4 based on both full spectra and characteristic lines. The weak correlations between conventionally analyzed soil AP and AK and soil LIBS spectra are responsible for the poor prediction abilities of AP and AK contents. Findings from this study demonstrated that the LIBS technique combined with multivariate methods is a promising alternative for fast and simultaneous detection of some properties (i.e., pH and CEC) and nutrient contents (i.e., SOM, TN, TP, and TK) in farmland soils because of the extraordinary prediction performances achieved for these attributes.


2016 ◽  
Vol 8 (40) ◽  
pp. 7354-7360 ◽  
Author(s):  
Celio Pasquini ◽  
Benedito B. Farias Filho

The hyphenation of the micro-analytical sensing characteristics of LIBS with the ring-oven pre-concentration technique is improved through mechanization of the ring measurement and use of lithium as internal standard.


2016 ◽  
Vol 242 (10) ◽  
pp. 1685-1692 ◽  
Author(s):  
Gonca Bilge ◽  
Banu Sezer ◽  
Kemal Efe Eseller ◽  
Halil Berberoğlu ◽  
Hamit Köksel ◽  
...  

Talanta ◽  
2013 ◽  
Vol 117 ◽  
pp. 55-59 ◽  
Author(s):  
David A. Rusak ◽  
Ann E. Zeleniak ◽  
Jillian L. Obuhosky ◽  
Scott M. Holdren ◽  
Craig A. Noldy

2016 ◽  
Vol 8 (37) ◽  
pp. 6705-6710 ◽  
Author(s):  
Pengcheng Han ◽  
Daming Dong ◽  
Xiaofan Du ◽  
Leizi Jiao ◽  
Xiande Zhao

Laser-induced breakdown spectroscopy was used for the fast determination of calcium concentration in the internal tissues of a single seed. Compared with conventional methods, LIBS had obvious advantages, such as a little analysis spot, little ablation, high precision, and small influence on the seed vigor.


Sign in / Sign up

Export Citation Format

Share Document