Isoprene versus Monoterpenes as Gas-Phase Organic Acid Precursors in the Atmosphere

Author(s):  
Michael F. Link ◽  
Patrick Brophy ◽  
S. Ryan Fulgham ◽  
Trey Murschell ◽  
Delphine K. Farmer
Keyword(s):  
2005 ◽  
Vol 52 (1-2) ◽  
pp. 473-478 ◽  
Author(s):  
K. Boe ◽  
D.J. Batstone ◽  
I. Angelidaki

A headspace chromatographic method has been applied to measure volatile fatty acids in anaerobic digesters using gas phase extraction at pH less than 2 and temperature higher than 65 °C. The concentration of volatile fatty acids in liquid and gas phase can be correlated in the form of Henry's coefficient. Analysis of different factors in the batch indicated that pH, temperature, and salt addition had a strong impact on apparent solubility, while liquid/gas volume ratio and organic acid concentration had little impact. Larger liquid volume had a positive impact on extraction efficiency, while increased gas headspace had a negative impact, indicating that the system was total mass-limited. The best conditions were at pH < 2.0, and temperatures above 75 °C. The advantage of an automated gas-extraction system for organic acid analysis, compared to an automated liquid system is that it contains no filter element, which is susceptible to fouling in manure samples or samples with high solid content. An automated system which included a valerate pulse to the parent reactor was implemented, and operated for a short period.


2018 ◽  
Vol 11 (9) ◽  
pp. 5087-5104 ◽  
Author(s):  
Theodora Nah ◽  
Yi Ji ◽  
David J. Tanner ◽  
Hongyu Guo ◽  
Amy P. Sullivan ◽  
...  

Abstract. The sources and atmospheric chemistry of gas-phase organic acids are currently poorly understood, due in part to the limited range of measurement techniques available. In this work, we evaluated the use of SF6- as a sensitive and selective chemical ionization reagent ion for real-time measurements of gas-phase organic acids. Field measurements are made using chemical ionization mass spectrometry (CIMS) at a rural site in Yorkville, Georgia, from September to October 2016 to investigate the capability of this measurement technique. Our measurements demonstrate that SF6- can be used to measure a range of organic acids in the atmosphere. One-hour averaged ambient concentrations of organic acids ranged from a few parts per trillion by volume (ppt) to several parts per billion by volume (ppb). All the organic acids displayed similar strong diurnal behaviors, reaching maximum concentrations between 17:00 and 19:00 EDT. The organic acid concentrations are dependent on ambient temperature, with higher organic acid concentrations being measured during warmer periods.


2008 ◽  
Vol 21 (2) ◽  
pp. 112-118 ◽  
Author(s):  
Alireza Fattahi ◽  
Elham Tavasoli

2007 ◽  
Vol 9 (37) ◽  
pp. 5084 ◽  
Author(s):  
Yan Ma ◽  
Thomas Luciani ◽  
Rachel A. Porter ◽  
Andrew T. Russell ◽  
David Johnson ◽  
...  

2018 ◽  
Author(s):  
Bastian Stieger ◽  
Gerald Spindler ◽  
Dominik van Pinxteren ◽  
Achim Grüner ◽  
Markus Wallasch ◽  
...  

Abstract. A method is presented to quantify the low-molecular weight organic acids formic, acetic, propionic, butyric, pyruvic, glycolic, oxalic, malonic, succinic, malic, glutaric, and methanesulfonic acid in the atmospheric gas and particle phase in a two-hourly time resolution, based on a combination of the Monitor for AeRosols and Gases in ambient Air (MARGA) and an additional ion chromatography (IC) instrument. A proper separation of the organic target acids was initially tackled by a laboratory IC optimization study, testing different separation columns, eluent compositions and eluent flow rates both for isocratic and for gradient elution. Satisfactory resolution of all compounds was achieved using a gradient system with two coupled anion exchange separation columns. Online pre-concentration with an enrichment factor of approximately 400 was achieved by solid phase extraction consisting of a methacrylate polymer based sorbent with quaternary ammonium groups. The limits of detection of the method range between 7.1 ng m−3 for methanesulfonate and 150.3 ng m−3 for pyruvate. Precisions are below 1.0 %, except for glycolate (2.9 %) and succinate (1.0 %). Comparisons of inorganic anions measured at the TROPOS research site in Melpitz, Germany, by the original MARGA and the additional organic acid IC systems are in agreement with each other (R2 = 0.95 − 0.99). Organic acid concentrations from May 2017 as an example period are presented. Monocarboxylic acids were dominant in the gas phase with mean concentrations of 553 ng m−3 for acetic acid, followed by formic (286 ng m−3), pyruvic acid (182 ng m−3), propionic (179 ng m−3), butyric (98 ng m−3) and glycolic (71 ng  m−3). Particulate glycolate, oxalate and methanesulfonate were quantified with mean concentrations of 63 ng  m−3, 74 ng m−3 and 35 ng m−3, respectively. Elevated concentrations in the late afternoon of gas phase formic acid and particulate oxalate indicate a photochemical formation.


1991 ◽  
Vol 95 (16) ◽  
pp. 6329-6336 ◽  
Author(s):  
J. T. Jayne ◽  
S. X. Duan ◽  
P. Davidovits ◽  
D. R. Worsnop ◽  
M. S. Zahniser ◽  
...  

2020 ◽  
Author(s):  
Zhe Chen ◽  
Na Wang ◽  
Shu-Feng Pang ◽  
Yun-Hong Zhang

<p>Due to significant influence on global climate and human health, atmospheric aerosols have attracted numerous interests from the atmospheric science community. To provide insight into the aerosol effect, it is indispensable to investigate the aerosol properties comprehensively.</p><p>Since atmospheric aerosols are surrounded by substantial gas phase and have high specific surface area, the composition partitioning between particle phase and gas phase must be considered as a key aerosol property, which is termed as volatility for volatile organic/inorganic components. Recent studies show that the aerosol volatility can also be induced by the reaction of components in addition to the volatile compositions. Herein, we summarize four types of volatility induced by reaction, namely chloride depletion, nitrate depletion, ammonia depletion and volatility induced by salt hydrolysis. For chloride depletion and nitrate depletion, these processes can be regarded as reactions that strong acids are substituted by weak acids. The high volatility of the formed HCl or HNO<sub>3</sub> drives the reaction continuously moving forward.</p><p>For ammonium depletion, we observed the reaction occurs between (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub> and organic acid salts during dehydration process by ATR-FTIR. For example, when molar ratio is 1:1, significant depletion of ammonium was observed in the disodium succinate/(NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub> particles, indicating the evaporation of NH<sub>3</sub>. Besides, the hygroscopicity of the aerosol particles decreased after the dehydration, which should be attributed to the formation of less hygroscopic succinic acid and ammonium depletion. By regarding organic acid salts as weak bases, the ammonium depletion is a reaction that strong base substituted by weak base, driving by the continuous release of NH<sub>3</sub>. In addition to volatility induced by reactions within multi-component aerosols, we also found that the salt hydrolysis can also cause the formation of volatile product. For magnesium acetate (MgAc<sub>2</sub>) aerosols, we found significant water loss of the aerosol particles under constant relative humidity condition, while the amount of acetate was also decreased. We infer that the acetic acid (HAc) evaporation is caused by the hydrolysis of MgAc<sub>2</sub>, leading to the volatility and declined hygroscopicity. Two factors contribute to the volatility of MgAc<sub>2</sub> aerosols. One is the volatile acid donner (Ac<sup>2-</sup>), which can lead to the formation of volatile HAc. The other is the residual ion accepter (Mg<sup>2+</sup>), which can combine residual OH<sup>-</sup> after the proton is depleted by the evaporation of HAc. The formation of insoluble Mg(OH)<sub>2</sub> effectively maintains the aqueous pH in a suitable range, keeping the reaction moving forward. It should be noted that the co-exist of volatile acid donner and residual ion accepter is indispensable for the volatility induced by hydrolysis.</p><p>Generally, for the volatile species present in atmosphere, the aerosol volatility induced by the reaction of components can be an important pathway for their recycling processes. Due to the substantial composition modification, the hygroscopicity is also affected by such reaction. Therefore, this partitioning behavior of aerosols needs to be considered in the future atmospheric aerosol study, which may prevent the underestimate of particle volatilization or overestimate of hygroscopicity.</p>


Sign in / Sign up

Export Citation Format

Share Document