Behavior of Acrylodan-Labeled Human Serum Albumin Dissolved in Ionic Liquids

2008 ◽  
Vol 47 (3) ◽  
pp. 560-569 ◽  
Author(s):  
Taylor A. McCarty ◽  
Phillip M. Page ◽  
Gary A. Baker ◽  
Frank V. Bright
2011 ◽  
Vol 12 (4) ◽  
pp. 1072-1079 ◽  
Author(s):  
Yasar Akdogan ◽  
Matthias J. N. Junk ◽  
Dariush Hinderberger

2020 ◽  
Vol 142 (5) ◽  
pp. 1911-1917
Author(s):  
Proletina Kardaleva ◽  
Maya Guncheva ◽  
Svetla Todinova ◽  
Ivan Angelov ◽  
Paula Ossowicz ◽  
...  

2018 ◽  
Vol 20 (14) ◽  
pp. 9256-9268 ◽  
Author(s):  
R. Ravikanth Reddy ◽  
Ganesh Shanmugam ◽  
Balaraman Madhan ◽  
B. V. N. Phani Kumar

STD NMR and selective spin-relaxation analysis evidenced the selective binding (anionic part) of imidazole alkyl sulfate ionic liquids with proteins (HSA and collagen). These studies also enabled the ionic liquids to be ranked based on their binding affinities with the proteins of study.


2009 ◽  
Vol 113 (38) ◽  
pp. 12825-12830 ◽  
Author(s):  
Taylor A. Page ◽  
Nadine D. Kraut ◽  
Phillip M. Page ◽  
Gary A. Baker ◽  
Frank V. Bright

2022 ◽  
Author(s):  
Dorota Kowalska ◽  
Stefan Stolte ◽  
Dariusz Wyrzykowski ◽  
Piotr Stepnowski ◽  
Joanna Dołżonek

AbstractBioaccumulation potential is critical in PBT and risk assessment of chemicals. However, for ionic liquids (ILs), this aspect remains neglected. It is especially important to fill this gap, because for this group of compounds, existing data confirm their risk of being environmentally persistent and toxicity. Moreover, considering preliminary reports on the interactions of ILs with lipids, it may be assumed that ILs have a higher potential for bioaccumulation than indicated by previous estimations built upon octanol–water partition coefficients. Moreover, the bioconcentration of ionizable chemical compounds may also be strongly related to plasma protein contents. Therefore, in this work, the affinity of a set of imidazolium cations and organic anions, and their combination to human serum albumin (HSA) was determined. The obtained results reveal that both cations and anions can be strongly bound to HSA, and blood proteins might play an important role in overall bioaccumulation. Furthermore, it was observed that HSA binding properties towards IL cations depend on the hydrophobicity of cations. The obtained data also provide indication that cation–anion interaction may affect ILs ions affinity to HSA.


1969 ◽  
Vol 08 (01) ◽  
pp. 15-21 ◽  
Author(s):  
K. E. Scheer ◽  
J. Heep ◽  
W. Maier-Borst ◽  
W. J. Lorenz ◽  
H. Sinn ◽  
...  

ZusammenfassungNach tierexperimentellen Voruntersuchungen wurde die Placentographie mit trägerfreiem 113Inm -HSA als klinische Methode eingeführt. Vor Amniocentesen und bei Verdacht auf Placenta praevia werden Placentographien geschrieben. Den Schwangeren wird eine Aktivität von 500 μCi in die Cubitalvene injiziert. Die der Aktivität entsprechende Indiummenge ist kleiner als 0,1 ng. Die fetale Strahlenbelastung liegt unter lOmrad. Bei Anwendung von 113Inm-HSA entfällt eine Blockade der mütterlichen und fetalen Schilddrüsen. Die genaue Abgrenzung einer Placenta praevia wird nicht durch eine Blasenaktivität beeinträchtigt.Es wurden bisher 19 Placentalokalisationen durchgeführt. In allen Fällen konnte der Placentasitz eindeutig festgestellt werden. Bedingt durch die lange Liegezeit beim Aufnehmen eines Szintigramms kam es in zwei Fällen zu einem Vena-Cava-Kompressions-Syndrom. Zur Verhinderung dieser klinischen Zwischenfälle werden inzwischen Placentographien mit der Anger-Kamera aufgenommen. Mit Hilfe des divergierenden Kollimators konnte der gesamte Abdominalbereich erfaßt werden. Die Aufnahmezeit konnte auf 7 — 10 Minuten verkürzt werden. Die intravenöse injizierte Aktivität betrug bei dieser Methode ebenfalls 500 μCi. Der diagnostische Aussagewert der Kamerabilder ist szintigraphischen Aufnahmen gleichwertig.


Sign in / Sign up

Export Citation Format

Share Document