Tissue plasminogen activator as a novel diagnostic aid in acute pulmonary embolism

VASA ◽  
2014 ◽  
Vol 43 (6) ◽  
pp. 450-458 ◽  
Author(s):  
Julio Flores ◽  
Ángel García-Avello ◽  
Esther Alonso ◽  
Antonio Ruíz ◽  
Olga Navarrete ◽  
...  

Background: We evaluated the diagnostic efficacy of tissue plasminogen activator (tPA), using an enzyme-linked immunosorbent assay (ELISA) and compared it with an ELISA D-dimer (VIDAS D-dimer) in acute pulmonary embolism (PE). Patients and methods: We studied 127 consecutive outpatients with clinically suspected PE. The diagnosis of PE was based on a clinical probability pretest for PE and a strict protocol of imaging studies. A plasma sample to measure the levels of tPA and D-dimer was obtained at enrollment. Diagnostic accuracy for tPA and D-dimer was determined by the area under the receiver operating characteristic (ROC) curve. Sensitivity, specificity, predictive values, and the diagnostic utility of tPA with a cutoff of 8.5 ng/mL and D-dimer with a cutoff of 500 ng/mL, were calculated for PE diagnosis. Results: PE was confirmed in 41 patients (32 %). Areas under ROC curves were 0.86 for D-dimer and 0.71 for tPA. The sensitivity/negative predictive value for D-dimer using a cutoff of 500 ng/mL, and tPA using a cutoff of 8.5 ng/mL, were 95 % (95 % CI, 88–100 %)/95 % (95 % CI, 88–100 %) and 95 % (95 % CI, 88–100 %)/94 %), respectively. The diagnostic utility to exclude PE was 28.3 % (95 % CI, 21–37 %) for D-dimer and 24.4 % (95 % CI, 17–33 %) for tPA. Conclusions: The tPA with a cutoff of 8.5 ng/mL has a high sensitivity and negative predictive value for exclusion of PE, similar to those observed for the VIDAS D-dimer with a cutoff of 500 ng/mL, although the diagnostic utility was slightly higher for the D-dimer.

2003 ◽  
Vol 127 (3) ◽  
pp. 310-315
Author(s):  
Julio Flores ◽  
Angel García-Avello ◽  
Victor M. Flores ◽  
JoséL. Navarro ◽  
Felipe Canseco ◽  
...  

Abstract Context.—Pulmonary embolism (PE) is a potentially fatal and frequent complication of deep venous thrombosis, and the most reliable techniques for the diagnosis of PE are not universally available and have other limitations. Objective.—To determine the efficacy of 4 different fibrinolysis system parameters, namely, tissue plasminogen activator (tPA), tissue plasminogen activator inhibitor type 1 (PAI-1), plasmin-antiplasmin complexes (PAP), and D-dimer, in the diagnosis of acute PE. Setting.—A 350-bed university hospital serving an area with 280 000 inhabitants. Patients.—Sixty-six consecutive outpatients with clinically suspected PE. The diagnosis of PE was based on ventilation-perfusion (V/Q) lung scan in combination with clinical assessment, lower limb study, and (when required) pulmonary angiography. Main Outcome Measures.—At the moment of clinical suspicion, a sample of venous blood was obtained to measure levels of tPA, PAI-1, PAP, and D-dimer using an enzyme-linked immunosorbent assay method. Results.—Twenty-seven patients (41%) were classified as PE positive (high clinical probability and V/Q lung scan [n = 12], nondiagnostic V/Q lung scan and high clinical probability [n = 1], inconclusive V/Q lung scan and positive lower limb examination for deep venous thrombosis [n = 11], and positive pulmonary angiography [n = 3]), and 39 patients (59%) were classified PE negative. The sensitivity/negative predictive value for tPA, using a cutoff of 8.5 ng/mL, and PAI-1, using a cutoff of 15 ng/mL, were 100%/100% and 100%/100%, respectively. A tPA level lower than 8.5 ng/mL occurred in 13 (19.7%; all PE negative) of 66 patients with suspected PE, and PAI-1 levels were lower than 15 ng/mL in 9 (13.6%; all PE negative) of 66 patients with suspected PE. The D-dimer, using a cutoff of 500 ng/mL, showed a sensitivity and negative predictive value of 92.6% and 87.5%, respectively. Conclusions.—Our data indicate that tPA and PAI-1 levels are potentially useful in ruling out PE, although tPA seems to be the better parameter. The sensitivity levels and negative predictive values for the rapid enzyme-linked immunosorbent assay for D-dimer used in this investigation were low compared with previous studies using the same test.


The Lancet ◽  
1986 ◽  
Vol 328 (8512) ◽  
pp. 886-889 ◽  
Author(s):  
SamuelZ. Goldhaber ◽  
JohnE. Markis ◽  
MichaelF. Meyerovitz ◽  
DuckSoo Kim ◽  
DouglasL. Dawley ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document