Very-Low-Frequency Heart Rate Variability: Mental Stressors in Tetraplegics

2010 ◽  
Author(s):  
N. Lynn De Paur
SLEEP ◽  
1996 ◽  
Vol 19 (5) ◽  
pp. 370-377 ◽  
Author(s):  
Toshiaki Shiomi ◽  
Christian Guilleminault ◽  
Ryujiro Sasanabe ◽  
Izumi Hirota ◽  
Masato Maekawa ◽  
...  

2016 ◽  
Vol 20 (3) ◽  
pp. 975-985 ◽  
Author(s):  
Ren-Jing Huang ◽  
Ching-Hsiang Lai ◽  
Shin-Da Lee ◽  
Wei-Che Wang ◽  
Ling-Hui Tseng ◽  
...  

2011 ◽  
Vol 26 (S2) ◽  
pp. 147-147
Author(s):  
T. Diveky ◽  
D. Kamaradova ◽  
A. Grambal ◽  
K. Latalova ◽  
J. Prasko ◽  
...  

The aim of our study is to measure very low frequency band (VLF), low frequency band (LF) and high frequency band (HF) components of R-R interval during orthostatic experiment in panic disorder patients before and after treatment.MethodsWe assessed heart rate variability in 19 patients with panic disorder before and after 6-weeks treatment with antidepressants combined with CBT and 18 healthy controls. They were regularly assessed on the CGI, BAI and BDI. Heart rate variability was assessed during 5 min standing, 5 min supine and 5 min standing positions before and after the treatment. Power spectra were computed using a fast Fourier transformation for very low frequency - VLF (0.0033 - 0.04 Hz), low-frequency - LF (0.04-0.15 Hz) and high frequency - HF (0.15-0.40 Hz) powers.Results19 panic disorder patients entered a 6-week open-label treatment study with combination of SSRI and cognitive behavioral therapy. A combination of CBT and pharmacotherapy proved to be the effective treatment of patients. They significantly improved in all rating scales. There were highly statistical significant differences between panic patients and control group in all components of power spectral analysis in 2nd and in two component of 3rd (LF and HF in standing) positions. There was also statistically significant difference between these two groups in LF/HF ratio in supine position (2nd). During therapy there was tendency to increasing values in all three positions in components of HRV power spectra, but there was only statistically significant increasing in HF1 component.Supported by project IGA MZ ČR NS 10301-3/2009


1996 ◽  
Vol 91 (4) ◽  
pp. 391-398 ◽  
Author(s):  
Piotr Ponikowski ◽  
Massimo Piepoli ◽  
Aham A. Amadi ◽  
Tuan Peng Chua ◽  
Derek Harrington ◽  
...  

1. In patients with chronic heart failure, heart rate variability is reduced with relative preservation of very-low-frequency power (< 0.04 Hz). Heart rate variability has been measured without acceptable information on its stability and the optimal recording periods for enhancing this reproducibility. 2. To this aim and to establish the optimal length of recording for the evaluation of the very-low-frequency power, we analysed 40, 20, 10 and 5 min ECG recordings obtained on two separate occasions in 16 patients with chronic heart failure. The repeatability coefficient and the variation coefficient were calculated for the heart rate variability parameters, in the time-domain (mean RR, SDRR and pNN50), and in the frequency-domain: very low frequency (< 0.04 Hz), low frequency (0.04–0.15 Hz), high frequency (0.15–0.40 Hz), total power (0–0.5 Hz). 3. Mean RR remained virtually identical over time (variation coefficient 8%). The reproducibility of time-domain (variation coefficient 25–139%) and of spectral measures (variation coefficient 45–111%) was very low. The stability of the heart rate variability parameters was only apparently improved after square root and after log transformation. 4. Very-low-frequency values derived from 5 and 10 min intervals were significantly lower than those calculated from 40 and 20 min intervals (P < 0.005). Discrete very-low-frequency peaks were detected in 11 out of 16 patients on the first 40, 20 and 10 min recording, but only in seven out of 16 when 5 min segments were analysed. 5. The reproducibility of both time or frequency-domain measures of heart rate variability in patients with chronic heart failure may vary significantly. Square root or log-transformed parameters may be considered rather than absolute units in studies assessing the influence of management on heart rate variability profile. Recordings of at least 20 min in stable, controlled conditions are to be recommended to optimize signal acquisition in patients with chronic heart failure, if very-low-frequency power in particular is to be studied.


Sign in / Sign up

Export Citation Format

Share Document