Supplemental Material for Muslim Daily Religiosity Assessment Scale (MUDRAS): A New Instrument for Muslim Religiosity Research and Practice

Author(s):  
Juan Aníbal González-Rivera ◽  
Adam Rosario-Rodríguez ◽  
Andrés Cruz-Santos

Background: The purpose of this study was to adapt and validate the Coronavirus Anxiety Scale in a sample of Hispanic residents in Puerto Rico. This instrument is a brief mental health screening to identify anxiety symptoms associated with COVID-19. Method: An availability sampling and a sample of 327 Spanish-speaking participants were used. Results: Psychometric analyses confirmed that the scale has a one-dimensional structure and solid reliability (Ω = .93) and validity. The five items met fair discrimination values, demonstrating that the instrument can distinguish between people with anxiety symptoms associated with COVID-19 and those without symptoms. According to the analyses performed, the cut-off points to identify significant symptoms of coronavirus anxiety was ≥ 10. The prevalence of significant symptoms of coronavirus anxiety was 15.29% (n = 50). Conclusions: These results support the scale as a useful and valid tool for clinical research and practice.


Author(s):  
H. Tochigi ◽  
H. Uchida ◽  
S. Shirai ◽  
K. Akashi ◽  
D. J. Evins ◽  
...  

A New High Excitation Objective Lens (Second-Zone Objective Lens) was discussed at Twenty-Sixth Annual EMSA Meeting. A new commercially available Transmission Electron Microscope incorporating this new lens has been completed.Major advantages of the new instrument allow an extremely small beam to be produced on the specimen plane which minimizes specimen beam damages, reduces contamination and drift.


Author(s):  
John F. Mansfield

The current imaging trend in optical microscopy, scanning electron microscopy (SEM) or transmission electron microscopy (TEM) is to record all data digitally. Most manufacturers currently market digital acquisition systems with their microscope packages. The advantages of digital acquisition include: almost instant viewing of the data as a high-quaity positive image (a major benefit when compared to TEM images recorded onto film, where one must wait until after the microscope session to develop the images); the ability to readily quantify features in the images and measure intensities; and extremely compact storage (removable 5.25” storage devices which now can hold up to several gigabytes of data).The problem for many researchers, however, is that they have perfectly serviceable microscopes that they routinely use that have no digital imaging capabilities with little hope of purchasing a new instrument.


Author(s):  
Lee H. Veneklasen

This paper discusses some of the unique aspects of a spectroscopic emission microscope now being tested in Clausthal. The instrument is designed for the direct parallel imaging of both elastic and inelastic electrons from flat surfaces. Elastic contrast modes of the familiar LEEM include large and small angle LEED, mirror microscopy, backscatter diffraction contrast (for imaging of surface structure), and phase contrast (for imaging of step dynamics)(1). Inelastic modes include topology sensitive secondary, and work function sensitive photoemission. Most important, the new instrument will also allow analytical imaging using characteristic Auger or soft X-ray emissions. The basic instrument has been described by Bauer and Telieps (2). This configuration has been redesigned to include an airlock, and a LaB6 gun, triple condensor lens, magnetic objective lens, a double focussing separator field, an imaging energy analyzer, and a real time image processor.Fig. 1 shows the new configuration. The basic beam voltage supply Vo = 20 KV, upon which separate supplies for the gun Vg, specimen Vs, lens electrode Vf, and analyzer bias Vb float. The incident energy at the sample can be varied from Vs = 0-1 KV for elastic imaging, or from Vg + Vs = (3 + Vs) KV for inelastic imaging. The image energy window Vs±V/2 may be varied without readjusting either the illumation, or imaging/analyzer optics. The diagram shows conjugate diffraction and image planes. The apertures defining incoming Humiliation and outgoing image angles are placed below the separator magnet to allow for their independent optimization. The instrument can illuminate and image 0.5-100 μm fields at 0-1 keV emission energies with an energy window down to 0.2 eV.


Sign in / Sign up

Export Citation Format

Share Document