scholarly journals Comparative evaluation of tractography-based direct targeting and atlas-based indirect targeting of the ventral intermediate (Vim) nucleus in MRgFUS thalamotomy

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Federico Bruno ◽  
Alessia Catalucci ◽  
Marco Varrassi ◽  
Francesco Arrigoni ◽  
Patrizia Sucapane ◽  
...  

AbstractTo analyze and compare direct and indirect targeting of the Vim for MRgFUS thalamotomy. We retrospectively evaluated 21 patients who underwent unilateral MRgFUS Vim ablation and required targeting repositioning during the procedures. For each patient, in the three spatial coordinates, we recorded: (i) indirect coordinates; (ii) the coordinates where we clinically observed tremor reduction during the verification stage sonications; (iii) direct coordinates, measured on the dentatorubrothalamic tract (DRTT) at the after postprocessing of DTI data. The agreement between direct and indirect coordinates compared to clinically effective coordinates was evaluated through the Bland–Altman test and intraclass correlation coefficient. The median absolute percentage error was also calculated. Compared to indirect targeting, direct targeting showed inferior error values on the RL and AP coordinates (0.019 vs. 0.079 and 0.207 vs. 0.221, respectively) and higher error values on the SI coordinates (0.263 vs. 0.021). The agreement between measurements was higher for tractography along the AP and SI planes and lower along the RL planes. Indirect atlas-based targeting represents a valid approach for MRgFUS thalamotomy. The direct tractography approach is a valuable aid in assessing the possible deviation of the error in cases where no immediate clinical response is achieved.

2002 ◽  
Vol 46 (11) ◽  
pp. 3644-3647 ◽  
Author(s):  
Manuel Cuenca-Estrella ◽  
Wendy Lee-Yang ◽  
Meral A. Ciblak ◽  
Beth A. Arthington-Skaggs ◽  
Emilia Mellado ◽  
...  

ABSTRACT A two-laboratory study was performed to evaluate the correlation between the NCCLS M27-A and EUCAST microdilution procedures for antifungal testing of Candida spp. A panel of 109 bloodstream isolates was tested against amphotericin B, flucytosine, fluconazole, and itraconazole. Overall, the agreement was 92% and the intraclass correlation coefficient was 0.90 (P < 0.05).


Author(s):  
Theodore G Papaioannou ◽  
Dimitrios Xanthis ◽  
Antonis Argyris ◽  
Pavlos Vernikos ◽  
Georgia Mastakoura ◽  
...  

Non-invasive monitoring of cardiac output is a technological and clinical challenge, especially for critically ill, surgically operated, or intensive care unit patients. A brachial cuff-based, automated, oscillometric device used for blood pressure and arterial stiffness ambulatory monitoring (Mobil-O-Graph) provides a non-invasive estimation of cardiac output values simultaneously with regular blood pressure measurement. The aim of the study was to evaluate the feasibility of this apparatus to estimate cardiac output in intensive care unit patients and to compare the non-invasive estimated cardiac output values with the respective gold standard method of thermodilution during pulmonary artery catheterization. Repeated sequential measurements of cardiac output were performed, in random order, by thermodilution (reference) and Mobil-O-Graph (test), in 24 patients hospitalized at intensive care unit. Reproducibility and accuracy of the test device were evaluated by Bland–Altman analysis, intraclass correlation coefficient, and percentage error. Mobil-O-Graph underestimated significantly the cardiac output by −1.12 ± 1.38 L/min ( p < 0.01) compared to thermodilution. However, intraclass correlation coefficient was >0.7 indicating a fair agreement between the test and the reference methods, while percentage error was approximately 39% which is considered to be within the acceptable limits. Cardiac output measurements were reproducible by both Mobil-O-Graph (intraclass correlation coefficient = 0.73 and percentage error = 27.9%) and thermodilution (intraclass correlation coefficient = 0.91 and percentage error = 26.7%). We showed for the first time that cardiac output estimation in intensive care unit patients using a non-invasive, automated, oscillometric, cuff-based apparatus is reproducible (by analyzing two repeated cardiac output measurements), exhibiting similar precision to thermodilution. However, the accuracy of Mobil-O-Graph (error compared to thermodilution) could be considered fairly acceptable. Future studies remain to further examine the reliability of this technology in monitoring cardiac output or stroke volume acute changes which is a more clinically relevant objective.


2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Bo Zhang ◽  
Jianjun Gu ◽  
Xiaoxiao Zhang ◽  
Bin Yang ◽  
Zheng Wang ◽  
...  

Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device.Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at various posterior pressures. The eight isolated rabbit corneas were mounted on the Barron artificial chamber and images of the anterior segment were taken at posterior pressures of 15, 30, 45, 60, and 75 mmHg by the device. The repeatability and reliability of the parameters including CCT, ACD, ACV, and CV were evaluated at each posterior pressure. All the variations of the parameters at the different posterior pressures were calculated.Results. All parameters showed good intraobserver reliability (Cronbach’s alpha; intraclass correlation coefficient,α, ICC > 0.96) and repeatability in the modified Scheimpflug device. With the increase of posterior pressures, the ratio of CCT decreased linearly and the bulk modulus gradually reduced to a platform. The increase of ACD was almost linear with the posterior pressures elevated.Conclusions. The modified Scheimpflug device was a valuable tool to investigate the biomechanics of the cornea. The posterior pressure 15–75 mmHg range produced small viscoelastic deformations and nearly linear pressure-deformation response in the rabbit cornea.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Lloyd Roberts ◽  
Tom Rozen ◽  
Deirdre Murphy ◽  
Adam Lawler ◽  
Mark Fitzgerald ◽  
...  

Abstract Background Multiple screening Duplex ultrasound scans (DUS) are performed in trauma patients at high risk of deep vein thrombosis (DVT) in the intensive care unit (ICU). Intensive care physician performed compression ultrasound (IP-CUS) has shown promise as a diagnostic test for DVT in a non-trauma setting. Whether IP-CUS can be used as a screening test in trauma patients is unknown. Our study aimed to assess the agreement between IP-CUS and vascular sonographer performed DUS for proximal lower extremity deep vein thrombosis (PLEDVT) screening in high-risk trauma patients in ICU. Methods A prospective observational study was conducted at the ICU of Alfred Hospital, a major trauma center in Melbourne, Australia, between Feb and Nov 2015. All adult major trauma patients admitted with high risk for DVT were eligible for inclusion. IP-CUS was performed immediately before or after DUS for PLEDVT screening. The paired studies were repeated twice weekly until the DVT diagnosis, death or ICU discharge. Written informed consent from the patient, or person responsible, or procedural authorisation, was obtained. The individuals performing the scans were blinded to the others’ results. The agreement analysis was performed using Cohen’s Kappa statistics and intraclass correlation coefficient for repeated binary measurements. Results During the study period, 117 patients had 193 pairs of scans, and 45 (39%) patients had more than one pair of scans. The median age (IQR) was 47 (28–68) years with 77% males, mean (SD) injury severity score 27.5 (9.53), and a median (IQR) ICU length of stay 7 (3.2–11.6) days. There were 16 cases (13.6%) of PLEDVT with an incidence rate of 2.6 (1.6–4.2) cases per 100 patient-days in ICU. The overall agreement was 96.7% (95% CI 94.15–99.33). The Cohen’s Kappa between the IP-CUS and DUS was 0.77 (95% CI 0.59–0.95), and the intraclass correlation coefficient for repeated binary measures was 0.75 (95% CI 0.67–0.81). Conclusions There is a substantial agreement between IP-CUS and DUS for PLEDVT screening in trauma patients in ICU with high risk for DVT. Large multicentre studies are needed to confirm this finding.


Author(s):  
Daniela Claessens ◽  
Alexander K. Schuster ◽  
Ronald V. Krüger ◽  
Marian Liegl ◽  
Laila Singh ◽  
...  

AbstractIn this study, the test-retest-reliability as one aspect of reliability of metamorphopsia measurements using a computer-based measuring method was determined in patients with macular diseases. Metamorphopsia amplitude, position, and area were quantified using AMD – A Metamorphopsia Detector software (app4eyes GmbH & Co. KG, Germany) in patients with diabetic, myopic, or uveitic macular edema, intermediate or neovascular age-associated macular degeneration, epiretinal membrane, vitelliform maculopathy, Irvine-Gass syndrome, or macular edema due to venous retinal occlusion. The intraclass correlation coefficient (ICC) was calculated in order to determine the repeatability of two repeated measurements and was used as an indicator of the reliability of the measurements. In this study, metamorphopsia measurements were conducted on 36 eyes with macular diseases. Metamorphopsia measurements made using AMD – A Metamorphopsia Detector software were highly reliable and repeatable in patients with maculopathies. The intraclass correlation coefficient of all indices was excellent (0.95 – 0.97). For diseases of the vitreoretinal interface or macular diseases with intra- or subretinal edema, this metamorphopsia measurement represents a supplement for visual function testing in the clinic, as well as in clinical studies.