Partial least-squares–Fourier transform infrared spectrometric determination of methanol and ethanol by vapour-phase generation

The Analyst ◽  
1998 ◽  
Vol 123 (6) ◽  
pp. 1253-1258 ◽  
Author(s):  
A. Pérez-Ponce ◽  
M. de la Guardia
1981 ◽  
Vol 35 (1) ◽  
pp. 102-106 ◽  
Author(s):  
Paul C. Painter ◽  
Susan M. Rimmer ◽  
Randy W. Snyder ◽  
Alan Davis

The application of Fourier transform infrared spectroscopy to the quantitative determination of mineral matter in coal is discussed. The use of a least squares curve-fitting program allows a choice between standards to be made. The results of an analysis of mineral mixtures and a coal low temperature ash are presented. The results are in good agreement with known concentrations and those obtained by other methods of analysis.


2014 ◽  
Vol 70 (5) ◽  
Author(s):  
Nor Fazila Rasaruddin ◽  
Mas Ezatul Nadia Mohd Ruah ◽  
Mohamed Noor Hasan ◽  
Mohd Zuli Jaafar

This paper shows the determination of iodine value (IV) of pure and frying palm oils using Partial Least Squares (PLS) regression with application of variable selection. A total of 28 samples consisting of pure and frying palm oils which acquired from markets. Seven of them were considered as high-priced palm oils while the remaining was low-priced. PLS regression models were developed for the determination of IV using Fourier Transform Infrared (FTIR) spectra data in absorbance mode in the range from 650 cm-1 to 4000 cm-1. Savitzky Golay derivative was applied before developing the prediction models. The models were constructed using wavelength selected in the FTIR region by adopting selectivity ratio (SR) plot and correlation coefficient to the IV parameter. Each model was validated through Root Mean Square Error Cross Validation, RMSECV and cross validation correlation coefficient, R2cv. The best model using SR plot was the model with mean centring for pure sample and model with a combination of row scaling and standardization of frying sample. The best model with the application of the correlation coefficient variable selection was the model with a combination of row scaling and standardization of pure sample and model with mean centering data pre-processing for frying sample. It is not necessary to row scaled the variables to develop the model since the effect of row scaling on model quality is insignificant.


2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Siong Fong Sim ◽  
Amelia Laccy Jeffrey Kimura

Fourier transform infrared (FTIR) spectroscopy has been advocating a promising alternative for Karl Fischer titration method for quantification of moisture in oil. This study aims to integrate partial least squares regression (PLSR) approach on FTIR spectra for prediction of moisture in locally accessible transformer oil and lubricating oil. The oil samples spiked with known moisture concentrations were extracted with acetonitrile and subjected to analysis with an FTIR spectrophotometer. The PLSR model was built based on 100 training/test splits, and the prediction performance was measured with the percentage root mean squares error (% RMSE). The range of concentration studied was between 0 and 5000 ppm. The marker region of moisture was found at 3750–3400 and 1700–1600 cm−1 with the latter demonstrating a better predictive ability in both lubricating oil and transformer oil. The prediction of moisture in lubricating oil was characterized with lower % RMSE. At concentration less than 700 ppm, the prediction accuracy deteriorates suggesting poor sensitivity. The PLSR was implemented on IR spectra of a set of blind samples, verified with Karl Fischer (for transformer oil) method and Kittiwake (for lubricating oil) method. The prediction was encouraging at concentrations above 1000 ppm; at lower concentrations, the prediction was characterized with high percent error. The algorithm, validated with 100 training/test splits, was converted into an executable program for prediction of moisture based on FTIR spectra. This program can be used for prediction of other substances given that the marker region is identified. FTIR can be used for prediction of moisture in oil nevertheless the sensitivity and precision is low for samples with low moisture concentration.


2006 ◽  
Vol 569 (1-2) ◽  
pp. 238-243 ◽  
Author(s):  
Sergio Armenta ◽  
Francesc A. Esteve-Turrillas ◽  
Guillermo Quintás ◽  
Salvador Garrigues ◽  
Agustín Pastor ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document