Distribution of zinc amongst human serum globulins determined by gel filtration-affinity chromatography and atomic-absorption spectrophotometry

The Analyst ◽  
1984 ◽  
Vol 109 (6) ◽  
pp. 709 ◽  
Author(s):  
John W. Foote ◽  
H. Trevor Delves
1975 ◽  
Vol 21 (4) ◽  
pp. 588-590 ◽  
Author(s):  
Berlslav Momčilović ◽  
Bartholomeus Belonje ◽  
Bhagwan G Shah

Abstract Zinc in pooled human serum, diluted 10-fold with demineralized water, was determined by flame atomic absorption spectrophotometry. Recoveries of zinc added to the serum were calculated by use of standards prepared in water, physiological saline, synthetic serum, or dilute HNO3 (10 ml/liter). The flow rates were essentially the same (9.1 to 9.3 ml/min) for water, diluted synthetic serum or actual human serum, and diluted nitric acid. The mean apparent percentage recoveries (±SD) were the best (102.6 ± 2.5) when the standards were prepared in nitric acid; the values obtained when standards in water were used were too high (111.5 ± 3.9); those with standards prepared in physiological saline (92.0 ± 3.2) or synthetic serum (92.3 ± 2.5) were too low.


1977 ◽  
Vol 38 (02) ◽  
pp. 0494-0503 ◽  
Author(s):  
D. S Pepper ◽  
D Banhegyi ◽  
J. D Cash

SummaryAntithrombin III (AT III) complexes were isolated from human serum by affinity chromatography and gel filtration. In the first step of the preparation, using heparin-agarose chromatography, we observed that the complexed form of AT III bound less strongly to the gel than the free form and that about half of the AT III was free. With further purification a 2.5 × 105 molecular weight complex was isolated. Using 125I labelled human thrombin, this complex was radioactive indicating the presence of thrombin. Only in a synthetic thrombin-AT III system was a 9 × 104 molecular weight complex detected, but not in serum. These facts suggest that in serum AT III complexes may exist in a polymeric form. Also, an AT III antigen derived from the original AT III molecule, but not complexed, was isolated which may be a degradation product.Abbreviations used: AT-III, antithrombin III. Hepes, N-2-Hydroxyethylpiperazine-N-2-Ethanesulphonic acid.


2020 ◽  
Vol 2 (1) ◽  
Author(s):  
Rizki Andalia ◽  
Mulia Aria Suzanni ◽  
Rini Rini

Lipstick or lip dye is a cosmetic dose that serves to coloring, decorative the lips, as a moisturizing material and protect the lips from exposure the sun to provide optimum results. Lipstick should not contain chemicals such as lead (Pb) because the Pb is a heavy metal that is very dangerous when continuously used on the skin, because it will be absorbed into the blood and attack the body organ causing the onset of disease. According to BPOM that the lead rate on the lipstick does not exceed the permissible limit of 20 mg/kg or 20 ppm.This research aims to know the levels contained in the samples are 4 brands of matte lipstick that are sold in the Aceh market in Banda Aceh City with the method of atomic absorption spectrophotometry (AAS). The results showed that on the 4 brands of lipstick matte contain heavy metal lead (Pb) with a rate still qualified allowed by BPOM  is samples A, B, C, and D, respectively at 0.24 ppm; 0.10 ppm; 2.87 ppm and 1.32 ppm, so that the 4 brands of lipstick matte are still used.


2015 ◽  
Vol 1 (1) ◽  
pp. 41
Author(s):  
Bella Santa Rossi ◽  
Paryanti Paryanti ◽  
Yuli Ristianingsih ◽  
Abubakar Tuhuloula

Pewarnaan pada proses produksi kain sasirangan menghasilkan limbah yang mengandung logam berat, diantaranya adalah timbal (Pb2+) dan kadmium (Cd2+). Penelitian ini bertujuan untuk mengetahui pengaruh proses fitoremediasi terhadap konsentrasi logam Pb2+ dan Cd2+ dari limbah cair industri sasirangan di Kalimantan Selatan, serta mengetahui pertambahan berat basah eceng gondok. Eceng gondok yang sudah dibersihkan dan diaklimatisasi ditanam dalam reaktor berisi larutan limbah dengan konsentrasi 3% (v/v); 9% (v/v); dan 15% (v/v). Sampel diambil setiap 2 hari sekali sebanyak 100 ml dan dianalisis menggunakan AAS (Atomic Absorption Spectrophotometry). Hasil penelitian ini menunjukkan bahwa konsentrasi logam Pb2+ dan Cd2+ dalam limbah setelah proses fitoremediasi terjadi penurunan. Kadar Pb2+ pada konsentrasi 3% (v/v) semula 0,197 ppm menjadi 0,062 ppm, pada konsentrasi 9% (v/v) semula 0,200 ppm menjadi 0,077 ppm dan untuk 15% (v/v) adalah 0,225 ppm menjadi 0,093 ppm. Sedangkan untuk Cd2+ konsentrasi 3% (v/v) semula 0,110 ppm menjadi 0,059 ppm, konsentrasi 9% (v/v) adalah 0,127 ppm menjadi 0,045 ppm dan untuk konsentrasi 15% (v/v) semula 0,144 ppm menjadi 0,047 ppm.


1965 ◽  
Vol 48 (6) ◽  
pp. 1100-1103
Author(s):  
C H Mcbride

Abstract The atomic absorption method studied last year was re-examined and extended to include calcium and sodium. The procedures were submitted to 16 collaborators for determination of Ca, Cu, Fe, Mg, Mn, Na, and Zn. Results for Ca and Na were discouraging; further study is recommended.


Sign in / Sign up

Export Citation Format

Share Document