Optical mesosensors for monitoring and removal of ultra-trace concentration of Zn(ii) and Cu(ii) ions from water

The Analyst ◽  
2012 ◽  
Vol 137 (22) ◽  
pp. 5278 ◽  
Author(s):  
Sherif A. El-Safty ◽  
M. A. Shenashen ◽  
M. Ismael ◽  
M. Khairy ◽  
Md. R. Awual
2015 ◽  
Vol 4 (2) ◽  
pp. 55
Author(s):  
Deswati ◽  
Hamzar Suyani ◽  
Bustanul Arifin ◽  
Imelda ◽  
Yunita Salamah

 ABSTRACT The research about determination of Cu(II) by adsorptive stripping voltammetry (AdSV) was conducted. AdSV method was applied to the determination of copper in ultra trace concentration. The parameters of ligand, accumulation potential, accumulation time, pH and ligand concentration was studied. Calcon was found as complexing agent that give the highest peak current. The optimum condition are accumulation potential -0,7 V, accumulation time 60 s, pH 10, and calcon concentration 0.12 mM. The relative standar deviation (n=8) at 10 µg/L standard concentration were obtained 4,27 %. This method was applied to determination of Cu(II) in sample from Batang Air Dingin, Lubuk Minturun and Muara Padang. The sample concentration were 4,778 µg/L and 5,189 µg/L for Batang Air Dingin and Muara Padang, respectively. The recovery of this method was studied for sample from Muara Padang and 98,31 % was obtained. Key words :   Adsorptive, Stripping, Voltammetry, Calcon and Copper    


RSC Advances ◽  
2018 ◽  
Vol 8 (63) ◽  
pp. 36360-36368 ◽  
Author(s):  
Durga Parajuli ◽  
Kiwamu Sue ◽  
Akira Takahashi ◽  
Hisashi Tanaka ◽  
Tohru Kawamoto

ZIF-8 nanoparticles highly selectively uptakes ultra-trace concentration arsenate. The material can be used for high precision monitoring of the ion when coupled with handy analytical tools.


2020 ◽  
Vol 1626 ◽  
pp. 461333 ◽  
Author(s):  
Nipunika H. Godage ◽  
Erasmus Cudjoe ◽  
Rabin Neupane ◽  
Sai HS. Boddu ◽  
Pradeep Kumar Bolla ◽  
...  

2018 ◽  
Vol 317 (2) ◽  
pp. 1141-1149 ◽  
Author(s):  
Amol M. Mhatre ◽  
Sankararao Chappa ◽  
C. V. Chaudhari ◽  
Y. K. Bhardwaj ◽  
Ashok K. Pandey

2020 ◽  
Vol 16 ◽  
Author(s):  
Wenshan Ni ◽  
Xiangju Mao ◽  
Hongli Zhang ◽  
Lu Liu ◽  
Xiaorui Guo ◽  
...  

Background: Platinum (Pt), palladium (Pd), rhodium (Rh) and iridium (Ir) are platinum group elements (PGEs) and also important elements of geochemistry and environmental chemistry with the similar physic-chemical properties, which have been widely used in industry and laboratory. However, due to the low abundance and inhomogeneous distribution in natural ore as well as the nugget effect, the accurate determination of PGEs has been a challenge to analytical chemistry. Methods: In this work, a novel fire assay method was reported for the determination of ultra-trace Pt, Pd, Rh and Ir in geochemical samples. Tin powder (Sn) instead of stannic oxide (SnO2) was used as fire assay collector to reduce the melting temperature from 1250 oC to 1050 oC, the escape of molten material caused by high temperature was successfully avoided. Tin bead was compressed into thin slice and dissolved by HCl. For the target Pt, Pd, Rh and Ir, HCl insoluble substance such as PtSn4, PdSn4, RhSn4 and Ir3Sn7 were formed and separated from matrix by filtering. The metal compounds precipitate together with filter paper were microwave-assisted completely digested by aqua regia (50%, v/v), thence the sample solution were determined by inductively coupled plasma mass spectrometry (ICP-MS). Results: Compared with nickel oxide and lead oxide in nickel sulfide /lead fire assay, the reagent blank of tin powder were relatively low and could be directly employed in tin fire assay to collect Pt, Pd, Rh and Ir without purifying. Moreover, the harm of nickel oxide and lead oxide to the analyst and environment was avoided by using the non-toxic tin powder. The decomposition method of chromite and black shale were investigated as well as the amount of tin powder and flour, microwave digestion program for the determination of Pt, Pd, Rh and Ir were optimized. Besides, the influence of mass spectrum interference of co-existing elements was discussed and the standard mode and kinetic energy discrimination collision pool mode were compared. Under the optimal conditions, excellent curve fitting of Pt, Pd, Rh and Ir were obtained between 0.01~100 ng mL-1 , with the correlation coefficients exceeding 0.9996. The detection limits were from 0.003 ng g -1 to 0.057 ng g -1 . Conclusion: The developed method was applied to analyze the Chinese Certified Reference Materials and the determined values were in good agreement with the certified values.


1989 ◽  
Vol 54 (10) ◽  
pp. 2667-2673 ◽  
Author(s):  
Vojtěch Steiner ◽  
Pavel Engst ◽  
Zdeněk Zelinger ◽  
Milan Horák

The optoacoustic analyzer with a tunable CO2 laser source employed in the present work permits a selective determination of ethylene in trace concentrations higher than 5 ppb (=detection limit for the 10P(14) emission line of the CO2 laser, ν = 949.5 cm-1) and of vinylchloride higher than 42 ppb (= detection limit for the 10P(22) CO2 laser line, ν= 942.4 cm-1). this method covers for both compounds the concentration range corresponding to the hygienic standard. It can be also used for the determination of styrene vapour with concentrations higher than 1.5 ppm.


Sign in / Sign up

Export Citation Format

Share Document