Direct mercury analysis in environmental solids by ICP-MS with on-line sample ashing and mercury pre-concentration using a direct mercury analyzer

2015 ◽  
Vol 30 (7) ◽  
pp. 1668-1672 ◽  
Author(s):  
Derek D. Bussan ◽  
Ryan F. Sessums ◽  
James V. Cizdziel

A commercially available direct mercury analyzer (DMA) based on sample combustion, pre-concentration by amalgamation with gold, and atomic absorption spectrophotometry (AAS) was coupled to a sector field inductively coupled plasma mass spectrometer (ICP-MS).

2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Amir A. Abdalla ◽  
Robert E. Smith

Mercury has been determined in Ayurvedic dietary supplements (Trifala, Trifala Guggulu, Turmeric, Mahasudarshan, Yograj, Shatawari, Hingwastika, Shatavari, and Shilajit) by inductively coupled plasma-mass spectrometry (ICP-MS) and direct mercury analysis using the Hydra-C direct mercury analyzer (Teledyne Leeman Labs Hudson, NH, USA). Similar results were obtained from the two methods, but the direct mercury analysis method was much faster and safer and required no microwave digestion (unlike ICP-MS). Levels of mercury ranged from 0.002 to 56 μg/g in samples of dietary supplements. Standard reference materials Ephedra 3240 and tomato leaves that were from the National Institute of Standard and Technology (NIST) and dogfish liver (DOLT3) that was from the Canadian Research Council were analyzed using Hydra-C method. Average mercury recoveries were 102% (RSD% 0.0018), 100% (RSD% 0.0009), and 101% (RSD% 0.0729), respectively. Hydra-C method Limit Of Quantitation was 0.5 ng.


2020 ◽  
Vol 35 (11) ◽  
pp. 2509-2516 ◽  
Author(s):  
Miriam García ◽  
Miguel Ángel Aguirre ◽  
Emilia Vassileva ◽  
Antonio Canals

The efficient mixing between the sample and the spike solutions takes place at the inner cavity of the multinebulizer tip.


2010 ◽  
Vol 93 (1) ◽  
pp. 323-326 ◽  
Author(s):  
Ni Zhang ◽  
Zhiying Ding ◽  
Hao Li ◽  
Xin Wang ◽  
Xiaodong Shao

Abstract A practical and nontarnishing method for the determination of trace nickel (Ni) in hydrogenated cottonseed oil by inductively coupled plasma/mass spectrometry (ICP/MS) was developed. In order to avoid tarnishing in the pretreatment of samples, the technology of pressurized PTFE vessel acid digestion was applied. The temperature and acid content in the digestion were optimized. The results showed that hydrogenated cottonseed oil could be digested completely by the proposed method. Compared with the U.S. Pharmacopeia 28 and British Pharmacopoeia 2003 methods, the developed method avoided the risk of using platinum and the tarnish from silica crucibles. In addition, the analytical cycle of the test solution was shortened by the use of ICP/MS instead of graphite furnace atomic absorption spectrophotometry.


Metallomics ◽  
2015 ◽  
Vol 7 (10) ◽  
pp. 1399-1406 ◽  
Author(s):  
Yuchuan Wang ◽  
Ligang Hu ◽  
Xinming Yang ◽  
Yuen-Yan Chang ◽  
Xuqiao Hu ◽  
...  

Quantitative analysis of metal selectivity of overexpressed metalloproteins in cells by GE-ICP-MS.