High-throughput evaluation of in situ-generated cobalt(iii) catalysts for acyl fluoride synthesis

2017 ◽  
Vol 7 (21) ◽  
pp. 4996-5003 ◽  
Author(s):  
Graham M. Lee ◽  
Roxanne Clément ◽  
R. Tom Baker

Using a high-throughput experimental procedure, a series of cobalt(iii) complexes of the general formula CpRCo(I)(X)(L) were prepared and screened for their activity towards the catalytic nucleophilic fluorination of benzoyl chloride.

2010 ◽  
Vol 399 (1-2) ◽  
pp. 52-59 ◽  
Author(s):  
Takashi Kojima ◽  
Shunichirou Tsutsumi ◽  
Katsuhiko Yamamoto ◽  
Yukihiro Ikeda ◽  
Toshiya Moriwaki

2016 ◽  
Vol 82 (15) ◽  
pp. 4757-4766 ◽  
Author(s):  
Caterina R. Giner ◽  
Irene Forn ◽  
Sarah Romac ◽  
Ramiro Logares ◽  
Colomban de Vargas ◽  
...  

ABSTRACTHigh-throughput sequencing (HTS) is revolutionizing environmental surveys of microbial diversity in the three domains of life by providing detailed information on which taxa are present in microbial assemblages. However, it is still unclear how the relative abundance of specific taxa gathered by HTS correlates with cell abundances. Here, we quantified the relative cell abundance of 6 picoeukaryotic taxa in 13 planktonic samples from 6 European coastal sites using epifluorescence microscopy on tyramide signal amplification-fluorescencein situhybridization preparations. These relative abundance values were then compared with HTS data obtained in three separate molecular surveys: 454 sequencing of the V4 region of the 18S ribosomal DNA (rDNA) using DNA and RNA extracts (DNA-V4 and cDNA-V4) and Illumina sequencing of the V9 region (cDNA-V9). The microscopic and molecular signals were generally correlated, indicating that a relative increase in specific 18S rDNA was the result of a large proportion of cells in the given taxa. Despite these positive correlations, the slopes often deviated from 1, precluding a direct translation of sequences to cells. Our data highlighted clear differences depending on the nucleic acid template or the 18S rDNA region targeted. Thus, the molecular signal obtained using cDNA templates was always closer to relative cell abundances, while the V4 and V9 regions gave better results depending on the taxa. Our data support the quantitative use of HTS data but warn about considering it as a direct proxy of cell abundances.IMPORTANCEDirect studies on marine picoeukaryotes by epifluorescence microscopy are problematic due to the lack of morphological features and due to the limited number and poor resolution of specific phylogenetic probes used in fluorescencein situhybridization (FISH) routines. As a consequence, there is an increasing use of molecular methods, including high-throughput sequencing (HTS), to study marine microbial diversity. HTS can provide a detailed picture of the taxa present in a community and can reveal diversity not evident using other methods, but it is still unclear what the meaning of the sequence abundance in a given taxon is. Our aim is to investigate the correspondence between the relative HTS signal and relative cell abundances in selected picoeukaryotic taxa. Environmental sequencing provides reasonable estimates of the relative abundance of specific taxa. Better results are obtained when using RNA extracts as the templates, while the region of 18S ribosomal DNA had different influences depending on the taxa assayed.


2017 ◽  
Vol 22 (10) ◽  
pp. 1203-1210 ◽  
Author(s):  
Katrin Beeman ◽  
Jens Baumgärtner ◽  
Manuel Laubenheimer ◽  
Karlheinz Hergesell ◽  
Martin Hoffmann ◽  
...  

Mass spectrometry (MS) is known for its label-free detection of substrates and products from a variety of enzyme reactions. Recent hardware improvements have increased interest in the use of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS for high-throughput drug discovery. Despite interest in this technology, several challenges remain and must be overcome before MALDI-MS can be integrated as an automated “in-line reader” for high-throughput drug discovery. Two such hurdles include in situ sample processing and deposition, as well as integration of MALDI-MS for enzymatic screening assays that usually contain high levels of MS-incompatible components. Here we adapt our c-MET kinase assay to optimize for MALDI-MS compatibility and test its feasibility for compound screening. The pros and cons of the Echo (Labcyte) as a transfer system for in situ MALDI-MS sample preparation are discussed. We demonstrate that this method generates robust data in a 1536-grid format. We use the MALDI-MS to directly measure the ratio of c-MET substrate and phosphorylated product to acquire IC50 curves and demonstrate that the pharmacology is unaffected. The resulting IC50 values correlate well between the common label-based capillary electrophoresis and the label-free MALDI-MS detection method. We predict that label-free MALDI-MS-based high-throughput screening will become increasingly important and more widely used for drug discovery.


Sign in / Sign up

Export Citation Format

Share Document