scholarly journals Electric field distributions along helium plasma jets

High Voltage ◽  
2020 ◽  
Vol 5 (6) ◽  
pp. 650-653 ◽  
Author(s):  
George V. Naidis ◽  
Natalia Yu Babaeva
1960 ◽  
Vol 118 (3) ◽  
pp. 626-631 ◽  
Author(s):  
Bernard Mozer ◽  
Michel Baranger

2013 ◽  
Vol 845 ◽  
pp. 372-377 ◽  
Author(s):  
Nabipour Afrouzi Hadi ◽  
Zulkurnain Abdul-Malek ◽  
Saeed Vahabi Mashak ◽  
A.R. Naderipour

Cross-linked polyethylene is widely used as electrical insulation because of its excellent electrical properties such as low dielectric constant, low dielectric loss and also due to its excellent chemical resistance and mechanical flexibility. Nevertheless, the most important reason for failure of high voltage equipment is due to its insulation failure. The electrical properties of an insulator are affected by the presence of cavities within the insulating material, in particular with regard to the electric field and potential distributions. In this paper, the electric field and potential distributions in high voltage cables containing single and multiple cavities are studied. Three different insulating media, namely PE, XLPE, and PVC was modeled. COMSOL software which utilises the finite element method (FEM) was used to carry out the simulation. An 11kV underground cable was modeled in 3D for better observation and analyses of the generated voltage and field distributions. The results show that the electric field is affected by the presence of cavities in the insulation. Furthermore, the field strength and uniformity are also affected by whether cavities are radially or axially aligned, as well as the type of the insulating solid. The effect of insulator type due the presence of cavities was seen most prevalent in PVC followed by PE and then XLPE.


2020 ◽  
Vol 53 (12) ◽  
pp. 125201
Author(s):  
P Seyfi ◽  
A Khademi ◽  
S Ghasemi ◽  
A Farhadizadeh ◽  
H Ghomi

Energies ◽  
2019 ◽  
Vol 12 (14) ◽  
pp. 2732 ◽  
Author(s):  
Disheng Wang ◽  
Lin Du ◽  
Chenguo Yao

The air’s partial discharges (PD) under DC voltage are obviously affected by space charges. Discharge pulse parameters have statistical regularity, which can be applied to analyze the space charge effects and discharge characteristics during the discharge process. Paper studies air corona discharge under DC voltage with needle-plate model. Statistical rules of repetition rate (n), amplitude (V) and interval time (∆t) are extracted, and corresponding space charge effects and electric field distributions in PD process are analyzed. The discharge stages of corona discharge under DC voltage are divided. Furthermore, reflected space charge effects, electric field distributions and discharge characteristics of each stages are summarized to better explain the stage discharge mechanism. This research verifies that microcosmic process of PD under DC voltage can be described based on statistical method. It contributes to the microcosmic illustration of gas PD with space charges.


Sign in / Sign up

Export Citation Format

Share Document