scholarly journals On the LFM signal improvement by piecewise vibrational resonance using a new spectral amplification factor

2019 ◽  
Vol 13 (1) ◽  
pp. 65-69 ◽  
Author(s):  
Pengxiang Jia ◽  
Jianhua Yang ◽  
Xin Zhang ◽  
Miguel A.F. Sanjuán
2020 ◽  
Vol 34 (06) ◽  
pp. 2050041
Author(s):  
Pengxiang Jia ◽  
Jianhua Yang ◽  
Yonggang Leng

We use two traditional indices and propose a new fusion index to quantify the echo chirp signal amplification effectively. They are the cross-correlation coefficient, the spectral amplification factor and the fusion index. Through investigating different numerical examples, we verify the validation of the re-scaled vibrational resonance (VR) method for the echo chirp signal by using the two traditional indices. Besides, taking into account that a single index has its own shortness, we combine the advantages of the two traditional indices mentioned and propose a new fusion index based on the information fusion method. Then we verify the superiority of the fusion index. Furthermore, the effect of noise on VR is also investigated. Finally, with the help of the adaptive inertia weight particle swarm optimization (APSO) algorithm, we propose the adaptive VR in noise background and verify its validity.


2004 ◽  
Vol 76 (1) ◽  
pp. 147-155 ◽  
Author(s):  
M. Musso ◽  
F. Matthai ◽  
D. Keutel ◽  
K.-L. Oehme

Isotropic Raman line shapes of simple molecular fluids exhibit critical line broadening near their respective liquid-gas critical points. In order to observe this phenomenon, it is essential that the band position of a given vibrational mode is density-dependent, and that vibrational depopulation processes negligibly contribute to line broadening. Special attention was given to the fact that the isotropic (i.e., nonrotationally broadened) line shape of liquid N2 is affected by resonant intermolecular vibrational interactions between identical oscillators. By means of the well-chosen isotopic mixture (14N2).975 - (14N15N).025, the temperature and density dependences of shift, width, and asymmetry of the resonantly coupled 14N2 and, depending on the S/N ratio available, of the resonantly uncoupled 14N15N were determined, with up to milli-Kelvin resolution, in the coexisting liquid and gas phases and along the critical isochore, using a highest-resolution double monochromator and modern charge-coupled device detection techniques. Clear evidence was found that vibrational resonance couplings are present in all dense phases studied.


Chemosensors ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 104
Author(s):  
Hung-Yang Kuo ◽  
Wei-Riu Cheng ◽  
Tzu-Heng Wu ◽  
Horn-Jiunn Sheen ◽  
Chih-Chia Wang ◽  
...  

This paper presents the synthesis and evaluation of a carbon molecular sieve membrane (CMSM) grown inside a MEMS-fabricated μ-preconcentrator for sampling highly volatile organic compounds. An array of µ-pillars measuring 100 µm in diameter and 250 µm in height were fabricated inside a microfluidic channel to increase the attaching surface for the CMSM. The surface area of the CMSM was measured as high as 899 m2/g. A GC peak amplification factor >2 × 104 was demonstrated with gaseous ethyl acetate. Up to 1.4 L of gaseous ethanol at the 100 ppb level could be concentrated without exceeding the capacity of this microchip device. Sharp desorption chromatographic peaks (<3.5 s) were obtained while using this device directly as a GC injector. Less volatile compounds such as gaseous toluene, m-xylene, and mesitylene appeared to be adsorbed strongly on CMSM, showing a memory effect. Sampling parameters such as sample volatilities, sampling capacities, and compound residual issues were empirically determined and discussed.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 491
Author(s):  
Sona Jain ◽  
Wanessa Santana ◽  
Silvio S. Dolabella ◽  
André L. S. Santos ◽  
Eliana B. Souto ◽  
...  

Leishmaniasis is one of the deadliest neglected tropical diseases affecting 12–15 million people worldwide, especially in middle- and low-income countries. Rapid and accurate diagnosis of the disease is important for its adequate management and treatment. Several techniques are available for the diagnosis of leishmaniasis. Among these, parasitological and immunological tests are most widely used. However, in most cases, the utilized diagnostic techniques are not good enough, showing cross-reactivity and reduced accuracy. In recent years, many new methods have been reported with potential for improved diagnosis. This review focuses on the diagnosis of Leishmania exploring the biosensors and nanotechnology-based options for their detection. New developments including the use of nanomaterials as fluorophores, fluorescence quenchers as reducing agents and as dendrimers for signal improvement and amplification, together with the use of aptamers to replace antibodies are described. Future research opportunities to overcome the current limitations on the available diagnostic approaches are also discussed.


Sign in / Sign up

Export Citation Format

Share Document