scholarly journals Specifics in the operating modes of thermosyphon air heater of steam generators №1 and №2 in TPP "Republika" at fuel switch from coal to natural gas

2019 ◽  
Vol 85 ◽  
pp. 01003 ◽  
Author(s):  
Iliya Iliev ◽  
Angel Terziev ◽  
Hristo Beloev ◽  
Christiyan Iliev

A fuel switch is motivated both by the necessity of increasing energy efficiency and the compliance with the ever-stricter regulations regarding the release of harmful emissions in the environment. In this paper a thorough financial and energy analysis on the fuel switch from coal to natural gas is carried out, in particular with respect to waste heat recovery systems (two phase thermosyphons). As a result of the calculation of the heat transfer coefficients for both fuels, it is established that the system running on natural gas has a lower value, due to the lower air velocity, caused in turn by the lower requirement for excess air. The heat transfer coefficients of the evaporation and condensation zones respectively are established hfgas=104.9 И hair=84.9 (W/m2.K) for coal and hfgas И hair =84.7 (W/m2.K) respectively for gas. A numerical study is also carried out and a methodology for the analysis of the efficiency of two phase thermosyphons with complex geometry is presented.

1983 ◽  
Vol 105 (4) ◽  
pp. 862-869 ◽  
Author(s):  
R. S. Amano ◽  
M. K. Jensen ◽  
P. Goel

An experimental and numerical study is reported on heat transfer in the separated flow region created by an abrupt circular pipe expansion. Heat transfer coefficients were measured along the pipe wall downstream from an expansion for three different expansion ratios of d/D = 0.195, 0.391, and 0.586 for Reynolds numbers ranging from 104 to 1.5 × 105. The results are compared with the numerical solutions obtained with the k ∼ ε turbulence model. In this computation a new finite difference scheme is developed which shows several advantages over the ordinary hybrid scheme. The study also covers the derivation of a new wall function model. Generally good agreement between the measured and the computed results is shown.


Author(s):  
Bingran Li ◽  
Cunliang Liu ◽  
Lin Ye ◽  
Huiren Zhu ◽  
Fan Zhang

Abstract To investigate the application of ribbed cross-flow coolant channels with film hole effusion and the effects of the internal cooling configuration on film cooling, experimental and numerical studies are conducted on the effect of the relative position of the film holes and different orientation ribs on the film cooling performance. Three cases of the relative position of the film holes and different orientation ribs (post-rib, centered, and pre-rib) in two ribbed cross-flow channels (135° and 45° orientation ribs) are investigated. The film cooling performances are measured under three blowing ratios by the transient liquid crystal measurement technique. A RANS simulation with the realizable k-ε turbulence model and enhanced wall treatment is performed. The results show that the cooling effectiveness and the downstream heat transfer coefficient for the 135° rib are basically the same in the three position cases, and the differences between the local effectiveness average values for the three are no more than 0.04. The differences between the heat transfer coefficients are no more than 0.1. The “pre-rib” and “centered” cases are studied for the 45° rib, and the position of the structures has little effect on the film cooling performance. In the different position cases, the outlet velocity distribution of the film holes, the jet pattern and the discharge coefficient are consistent with the variation in the cross flow. The related research previously published by the authors showed that the inclination of the ribs with respect to the holes affects the film cooling performance. This study reveals that the relative positions of the ribs and holes have little effect on the film cooling performance. This paper expands and improves the study of the effect of the internal cooling configuration on film cooling and makes a significant contribution to the design and industrial application of the internal cooling channel of a turbine blade.


2021 ◽  
Author(s):  
Avik Saha ◽  
Arup Kumar Das

Abstract Pool boiling around a heated cylinder having a diameter larger than the departure diameter of bubbles has been simulated numerically. Thermally uniform heat flux condition has been maintained at the outer surface of the cylinder, submerged at saturated water at atmospheric pressure. Using the Volume of Fluid type framework of liquid phase fraction in the domain, bubble life cycle around the horizontal cylinder has been analyzed to understand different stages of growth, sliding, merging prior to departure. An effort has also been made to characterize the bubble population, emerging from different sites over the cylindrical surface. The influence of cylinder inclination along its axis on these interfacial features has also been discussed using representative numerical simulation. Temperature profiles of the cylinder surface have been portrayed for both horizontal and inclined situations before presenting respective heat transfer coefficients.


Author(s):  
Koichi Araga ◽  
Keisuke Okamoto ◽  
Keiji Murata

This paper presents an experimental investigation of the forced convective boiling of refrigerant HCFC123 in a mini-tube. The inner diameters of the test tubes, D, were 0.51 mm and 0.30 mm. First, two-phase frictional pressure drops were measured under adiabatic conditions and compared with the correlations for conventional tubes. The frictional pressure drop data were lower than the correlation for conventional tubes. However, the data were qualitatively in accord with those for conventional tubes and were correlated in the form φL2−1/Xtt. Next, heat transfer coefficients were measured under the conditions of constant heat flux and compared with those for conventional tubes and for pool boiling. The heat transfer characteristics for mini-tubes were different from those for conventional tubes and quite complicated. The heat transfer coefficients for D = 0.51 mm increased with heat flux but were almost independent of mass flux. Although the heat transfer coefficients were higher than those for a conventional tube with D = 10.3 mm and for pool boiling in the low quality region, they decreased gradually with increasing quality. The heat transfer coefficients for D = 0.30 mm were higher than those for D = 0.51 mm and were almost independent of both mass flux and heat flux.


Author(s):  
Wenhai Li ◽  
Ken Alabi ◽  
Foluso Ladeinde

Over the years, empirical correlations have been developed for predicting saturated flow boiling [1–15] and condensation [16–30] heat transfer coefficients inside horizontal/vertical tubes or micro-channels. In the present work, we have examined 30 of these models, and modified many of them for use in compact plate-fin heat exchangers. However, the various correlations, which have been developed for pipes and ducts, have been modified in our work to make them applicable to extended fin surfaces. The various correlations have been used in a low-order, one-dimensional, finite-volume type numerical integration of the flow and heat transfer equations in heat exchangers. The NIST’s REFPROP database [31] is used to account for the large variations in the fluid thermo-physical properties during phase change. The numerical results are compared with Yara’s experimental data [32]. The validity of the various boiling and condensation models for a real plate-fin heat exchanger design is discussed. The results show that some of the modified boiling and condensation correlations can provide acceptable prediction of heat transfer coefficient for two-phase flows in compact plate-fin heat exchangers.


Author(s):  
Cheol Huh ◽  
Moo Hwan Kim

With a single microchannel and a series of microheaters made with MEMS technique, two-phase pressure drop and local flow boiling heat transfer were investigated using deionized water in a single horizontal rectangular microchannel. The test microchannel has a hydraulic diameter of 100 μm and length of 40 mm. A real time observation of the flow patterns with simultaneous measurement are made possible. Tests are performed for mass fluxes of 90, 169, and 267 kg/m2s and heat fluxes of from 100 to 600 kW/m2. The experimental local flow boiling heat transfer coefficients and two-phase frictional pressure gradient are evaluated and the effects of heat flux, mass flux, and vapor qualities on flow boiling are studied. Both the evaluated experimental data are compared with existing correlations. The experimental heat transfer coefficients are nearly independent on mass flux and the vapor quality. Most of all correlations do not provide reliable heat transfer coefficients predictions with vapor quality and prediction accuracy. As for two-phase pressure drop, the measured pressure drop increases with the mass flux and heat flux. Most of all existing correlations of two-phase frictional pressure gradient do not predict the experimental data except some limited conditions.


Author(s):  
Jason Chan ◽  
Brian E. Fehring ◽  
Roman W. Morse ◽  
Kristofer M. Dressler ◽  
Gregory F. Nellis ◽  
...  

Abstract A thermoreflectance method to measure wall temperature in two-phase annular flow is described. In high heat flux conditions, momentary dry-out occurs as the liquid film vaporizes, resulting in dramatic decreases in heat transfer coefficient. Simultaneous liquid and vapor thermoreflectance measurements allow calculations of instantaneous and time-averaged heat transfer coefficients. Validation, calibration and uncertainty of the technique are discussed.


Author(s):  
Haruhiko Ohta ◽  
Koichi Inoue ◽  
Yuichiro Shimada

Flow boiling heat transfer in a single small tube is investigated by using FC72 as a working fluid. The heat transfer coefficients are measured in the ranges of heat flux 2–24kW/m2 and mass velocity 100–400kg/m2s under the condition of near atmospheric pressure. Test tube, made of stainless steel, has an inner diameter of 0.51mm and a heated length of 200mm. The tube is located horizontally in a vacuum chamber to reduce the heat loss and to minimize the time to obtain data regarded as that of steady state. In the single-phase region, heat transfer coefficients due to forced convection are in good agreement with the values from the conventional theories. In the saturated region, measured heat transfer characteristics are quite different depending on whether the test liquid is deaerated or not deaerated before the experiments. By using deaerated liquid, three different heat transfer regimes are observed: In the first regime, the heat transfer is dominated by nucleate boiling in low vapor quality, and the heat transfer is deteriorated or enhanced depending on the channel confinement and heat flux. In the second regime, the heat transfer is dominated by two-phase forced convection in moderate quality as is well known for the tubes of normal size. In the third regime, the heat transfer is dominated again by two-phase forced convection, but is deteriorated in high quality. One or two regimes can disappear or become unclear depending on the conditions of flow and heating. The effects of vapor quality and mass velocity on the heat transfer characteristics due to two-phase forced convection in the moderate vapor quality are clarified in the experimental ranges tested. And a reason for the gradual heat transfer deterioration observed in high quality is discussed based on the liquid-vapor behaviors inherent in small diameter tubes.


2000 ◽  
Vol 122 (3) ◽  
pp. 485-491 ◽  
Author(s):  
G. A. Holtzman ◽  
R. W. Hill ◽  
K. S. Ball

A numerical study of natural convection in an isosceles triangular enclosure with a heated horizontal base and cooled upper walls is presented. Nearly every previous study conducted on this subject to date has assumed that the geometric plane of symmetry is also a plane of symmetry for the flow. This problem is re-examined over aspect ratios ranging from 0.2 to 1.0 and Grashof numbers from 103 to 105. It is found that a pitchfork bifurcation occurs at a critical Grashof number for each of the aspect ratios considered, above which the symmetric solutions are unstable to finite perturbations and asymmetric solutions are instead obtained. Results are presented detailing the occurrence of the pitchfork bifurcation in each of the aspect ratios considered, and the resulting flow patterns are described. A flow visualization study is used to validate the numerical observations. Computed local and mean heat transfer coefficients are also presented and compared with results obtained when flow symmetry is assumed. Differences in local values of the Nusselt number between asymmetric and symmetric solutions are found to be more than 500 percent due to the shifting of the buoyancy-driven cells. [S0022-1481(00)02503-2]


Sign in / Sign up

Export Citation Format

Share Document