scholarly journals The utility of a novel colonoscope with retroflexion for colorectal endoscopic submucosal dissection

2019 ◽  
Vol 07 (02) ◽  
pp. E130-E137 ◽  
Author(s):  
Hidenori Tanaka ◽  
Shiro Oka ◽  
Shinji Tanaka ◽  
Katsuaki Inagaki ◽  
Yuki Okamoto ◽  
...  

Abstract Background and study aims The PCF-H290TI/L produced by Olympus is a novel colonoscope equipped with some advantageous features for endoscopic treatment. It is expected to improve the potential for retroflexion and overall endoscope operability, which can reduce the difficulty of performing colorectal ESD. The aim of this study was to evaluate the utility of the novel colonoscope in colorectal ESD. Methods Three hundred and forty-eight consecutive colorectal lesions resected via ESD between June 2014 and January 2017 at Hiroshima University Hospital were included in the retroflexion ability analysis. We compared the retroflexion potential of PCF-H290TI to that of a conventional endoscope. Two hundred and twenty-seven colorectal lesions located in the left-sided colon and resected with ESD between April 2009 and February 2018 were enrolled in the treatment outcome analysis. Treatment outcomes using PCF-H290TI compared to those of the conventional colonoscope, and outcomes of the PCF-H290TI with retroflexion compared to those of the conventional colonoscope without retroflexion were evaluated by propensity score matching. Results The retroflexion rate with the PCF-H290TI was 76 %, which was significantly higher than the 44 % rate with the conventional scope. Endoscope operability was better and dissection speed was faster when using the PCF-H290TI with retroflexion compared to the conventional colonoscope without retroflexion. There were no significant differences between the groups in en bloc resection rate and adverse events. Conclusion Compared to the conventional colonoscope, the PCF-H290TI/L made it easier to perform ESD via a retrograde approach regardless of tumor location, and thus may be useful for performing colorectal ESD.

2019 ◽  
Vol 07 (09) ◽  
pp. E1166-E1174 ◽  
Author(s):  
Jérémie Jacques ◽  
Aurélie Charissoux ◽  
Pierre Bordillon ◽  
Romain Legros ◽  
Jérôme Rivory ◽  
...  

Abstract Background and study aims ESD in the colon is more challenging technically than in other locations. Here, we report the first comparative case series of colon ESD using a systematic countertraction strategy using two clips and a rubber band. Patients and methods Retrospective comparative study of classic versus countertraction colon ESD performed in colon ESD cases collected prospectively at Lyon Edouard Herriot Hospital and Limoges University Hospital from January 2016 until December 2017. Results The study included 192 cases (control = 76, countertraction = 116). Countertraction using the double clip and rubber band technique versus the control group resulted in a significant decrease in the procedure time (94.7 vs. 117 min; P = 0.004) and significant increases in procedure speed (28.2 vs. 16.7 mm2/min; P < 0.0001), en bloc resection rate (95.7 % vs. 76.3 %, P < 0.0001), and R0 resection rate (78.5 % vs. 64.5 %, P = 0.04).At an individual operator point of view, results varied between operators but the double clip countertraction strategy significantly increased the en bloc resection rate, R0 resection rate, and speed of dissection for each of the 4 operators. Conclusion Systematic countertraction using a double clip and rubber band facilitates colon ESD. This strategy should become the standard for colon ESD.


2021 ◽  
Vol 11 (1) ◽  
pp. 141
Author(s):  
Haruka Fujinami ◽  
Akira Teramoto ◽  
Saeko Takahashi ◽  
Takayuki Ando ◽  
Shinya Kajiura ◽  
...  

This study aimed to assess the utility of the S-O clip during colorectal endoscopic submucosal dissection (ESD). We conducted a retrospective study on 185 patients who underwent colorectal ESD from January 2015 to January 2020. The patients were divided into two groups: before and after the introduction of the S-O clip. Forty-two patients underwent conventional ESD (CO group) and 29 patients underwent ESD using the S-O clip (SO group). We compared the surgery duration, dissection speed, en bloc resection rate, and complication rate between both groups. Compared with the CO group, the SO group had a significantly shorter surgery duration (70.7 ± 37.9 min vs. 51.2 ± 18.6 min; p = 0.017), a significantly higher dissection speed (15.1 ± 9.0 min vs. 26.3 ± 13.8 min; p < 0.001), a significantly higher en bloc resection rate (80.9% vs. 98.8%; p ≤ 0.001), and a significantly lower perforation rate (4.3% vs. 1.3%). In the right colon, the surgery duration was significantly shorter and the dissection speed was significantly higher in the SO group than in the CO group. Moreover, the rate of en bloc resection improved significantly in the right colon. S-O clip-assisted ESD reduces the procedure time and improves the treatment effects, especially in the right colon.


2018 ◽  
Vol 06 (08) ◽  
pp. E975-E983 ◽  
Author(s):  
Naohisa Yoshida ◽  
Yuji Naito ◽  
Ritsu Yasuda ◽  
Takaaki Murakami ◽  
Ryohei Hirose ◽  
...  

Abstract Background and study aims Severe fibrosis poses a challenge in colorectal endoscopic submucosal dissection (ESD). Recently, the pocket-creation method (PCM) has been developed for overcoming various difficulties of ESD. A specific tapered hood is used for adequate traction in the PCM, and endoscopic operability becomes stable in the pocket. In this study, we investigated the efficacy of the PCM in ESD for cases with severe fibrosis. Patients and methods We retrospectively reviewed 1000 consecutive colorectal ESD cases (April 2006 to January 2017). Since 2016, the PCM was performed in 58 cases. The indications for ESD included (1) tumors ≥ 20 mm in size diagnosed as intramucosal cancer or high-grade dysplasia and part of T1a cancer using magnifying endoscopic examinations and (2) tumors that appeared impossible to resect with endoscopic mucosal resection because of suspected fibrosis. We identified 120 cases with severe fibrosis and compared them to cases without severe fibrosis. Additionally, the 120 severe fibrosis cases were divided into the PCM and non-PCM groups. En bloc resection, procedure time, discontinuation, and complications were analyzed between these 2 groups. Results Among all 1000 ESDs, severe fibrosis and discontinuation rates were 12.0 % (120 cases) and 1.8 % (18 cases), respectively. Regarding the comparison between cases with severe fibrosis and with no severe fibrosis, there were significant differences about en bloc resection rate (78.3 % vs. 95.7 %, P < 0.001), discontinuance rate (12.5 % vs. 0.3 %, P < 0.001), and perforation rate (8.3 % vs. 2.6 %, P = 0.001). Among the 120 cases with severe fibrosis, 21 and 99 cases were in the PCM and non-PCM groups, respectively. The PCM group had a higher en bloc resection rate (95.2 vs. 74.7, P =  0.03), a shorter mean procedure time (min) (79.6 ± 26.5 vs. 118.8 ± 71.0, P = 0.001), and no cases of discontinuation. An analysis of the interobserver agreement for the diagnosis of severe fibrosis among the 3 endoscopists showed kappa values of > 0.6. Conclusions In cases with severe fibrosis, the PCM with ESD improved en bloc resection rates and shortened the procedure time compared to the conventional non-PCM method. Additionally, the PCM reduced the discontinuation rate.


2020 ◽  
Vol 08 (03) ◽  
pp. E437-E444 ◽  
Author(s):  
Yuki Okamoto ◽  
Shiro Oka ◽  
Shinji Tanaka ◽  
Katsuaki Inagaki ◽  
Hidenori Tanaka ◽  
...  

Abstract Background and study aims In colorectal endoscopic submucosal dissection (ESD), the S-O clip improves the accessibility to the submucosal layer of the colon. However, its safety and usefulness in difficult colorectal ESDs are unclear. Thus, in this study, we aimed to assess the effectiveness of the S-O clip in colorectal ESD in the difficult-to-access submucosal layer. Patients and methods From January 2016 to December 2016, 189 consecutive cases of colorectal ESD were performed at Hiroshima University Hospital before the S-O clip was introduced. Between January 2017 and June 2018, among 271 consecutive colorectal ESD cases, 41 cases were performed colorectal ESD using the S-O clip. We compared outcomes between the two groups (41 cases with S-O clip [use group] and 189 cases without S-O clip [non-use group]) using propensity score matching. Results Prior to propensity score matching, 41 cases with the S-O clip (use group) and 189 cases without the S-O clip (non-use group) were extracted. The degree of submucosal fibrosis was more severe and the procedure time was longer in the use group than in the non-use group. In the use and non-use groups, en bloc resection (100 % vs. 94.7 %) and complete en bloc resection (100 % vs. 92.6 %) rates were satisfactory. After propensity score matching, 33 cases in each group were extracted. As a result, complete en bloc resection rate was significantly higher in the use group than in the non-use group (100 % vs. 84.9 %). Conclusion The S-O clip is effective and can be used safely in colorectal ESD in the difficult-to-access submucosal layer.


2020 ◽  
Vol 08 (12) ◽  
pp. E1832-E1839
Author(s):  
Yuichiro Kuroki ◽  
Toshiyuki Endo ◽  
Kenta Iwahashi ◽  
Naoki Miyao ◽  
Reika Suzuki ◽  
...  

Abstract Background and study aims Sessile serrated lesions (SSL) are major precursor lesions of serrated pathway cancers, and appropriate treatment may prevent interval colorectal cancer. Studies have reported the outcomes of endoscopic mucosal resection (EMR) for SSL; however, there are insufficient reports on endoscopic submucosal dissection (ESD). We examined the characteristics and outcomes of SSL and compared them to those of non-SSL in ESD. Patients and methods We reviewed 370 consecutive cases in 322 patients who underwent colorectal ESD between January 2016 and March 2020 at our hospital. There were 267 0-IIa lesions that were stratified into 41 SSL and 226 non-SSL (intramucosal cancer, adenoma) cases. We used propensity matching to adjust for the variances in the factors affecting treatment between the SSL and non-SSL groups. Results In the baseline cases, young women and proximal colon tumor location were significantly more common in the SSL group. There were no statistically significant differences between the SSL and non-SSL groups in terms of en bloc resection rate (97.6 % vs. 99.6 %; P = 0.28), R0 resection rate (92.7 % vs. 93.4 %; P = 0.74), perforation (0 % vs. 0.9 %; P > 0.99), and postoperative bleeding (2.4 % vs. 1.8 %; P = 0.56). Thirty-eight pairs were matched using propensity score, and the median dissection speed (12 vs. 7.7 cm2/h; P = 0.0095) was significantly faster in the SSL than in the non-SSL group. Conclusions ESD for SSL was safely performed, and SSL was smoother to remove than non-SSL. ESD might be an acceptable endoscopic treatment option for SSL.


2021 ◽  
Vol 09 (05) ◽  
pp. E653-E658
Author(s):  
Tatsuma Nomura ◽  
Yoshikazu Hayashi ◽  
Takaaki Morikawa ◽  
Masahiro Okada ◽  
Hisashi Fukuda ◽  
...  

Abstract Background and study aims The pocket-creation method (PCM) facilitates dissection of the central part of a tumor. We previously developed the PCM with clip traction (PCM-CT) to facilitate opening the mucosal pocket, which otherwise could become cumbersome. In the present study, we aimed to examine the feasibility of PCM-CT for colorectal endoscopic submucosal dissection (ESD). Patients and methods PCM-CT was performed on 30 patients with early colorectal tumors from October 2019 to April 2020. PCM-CT allows efficient opening of the mucosal pocket by using the PCM to dissect the center of the lesion and then apply traction with a single clip after making a circumferential mucosal incision. Results The median specimen major axis length, ESD time, ESD speed, and en bloc resection rate were 48 mm, 84 minutes, 20 mm2/min, and 100 % (30/30), respectively. The success rates for the traction clip and median single-clip-traction time were 100 % (30/30) and 1.5 minutes, respectively. Conclusions Colorectal ESD using PCM-CT is a simple and promising method.


2021 ◽  
Vol 93 (6) ◽  
pp. AB70
Author(s):  
William W. King ◽  
Peter V. Draganov ◽  
Andrew Y. Wang ◽  
Dushant Uppal ◽  
Nikhil A. Kumta ◽  
...  

2021 ◽  
Vol 10 (11) ◽  
pp. 2511
Author(s):  
Yoshitsugu Misumi ◽  
Kouichi Nonaka

Endoscopic submucosal dissection (ESD) is considered superior to endoscopic mucosal resection as an endoscopic resection because of its higher en bloc resection rate, but it is more difficult to perform. As ESD techniques have become more common, and the range of treatment by ESD has expanded, the number of possible complications has also increased, and endoscopists need to manage them. In this report, we will review the management of critical complications, such as hemorrhage, perforation, and stenosis, and we will also discuss educational methods for acquiring and improving ESD skills.


Author(s):  
Raffaele Manta ◽  
Angelo Zullo ◽  
Donato Alessandro Telesca ◽  
Danilo Castellani ◽  
Ugo Germani ◽  
...  

Abstract Background and Aims Ulcerative colitis [UC] patients are at an increased risk of developing colorectal cancer due to chronic inflammation. Endoscopic submucosal dissection [ESD] allows removal of non-invasive neoplastic lesions in the colon, but few data are available on its efficacy in UC patients. Methods Data from consecutive UC patients diagnosed with visible dysplastic lesions in the colon who underwent ESD were evaluated. The en bloc removal, R0 resection and complication rates were calculated. Local recurrence and metachronous lesions during follow-up were identified. A systematic review of the literature with pooled data analysis was performed. Results A total of 53 UC patients [age: 65 years; range 30–74; M/F: 31/22] underwent ESD. The en bloc resection rate was 100%, and the R0 resection rate was 96.2%. Bleeding occurred in seven [13.2%] patients, and perforation in three [5.6%] cases, all treated at endoscopy. No recurrence was observed, but two metachronous lesions were detected. Data from six other studies [three Asian and three European] were available. By pooling data, en bloc resection was successful in 88.4% (95% confidence interval [CI] = 83.5–92) of 216 lesions and in 91.8% [95% CI = 87.3–94.8] of 208 patients. R0 resection was achieved in 169 ESDs, equivalent to a 78.2% [95% CI = 72.3–83.2] rate for lesions and 81.3% [95% CI = 75.4–86] rate for patients. No difference between European and Asian series was noted. Conclusions This pooled data analysis indicated that ESD is a suitable tool for safely and properly removing non-invasive neoplastic lesions on colonic mucosa of selected UC patients.


Sign in / Sign up

Export Citation Format

Share Document