Untersuchungen zur Bildqualität von Thoraxaufnahmen von Katzen mit einem Needle-Image Plate (NIP) Detektor – ein Modell zur Bewertung der Bildqualität bei Neugeborenen

Author(s):  
E Ludewig ◽  
W Hirsch ◽  
K Gäbler ◽  
B Bosch ◽  
I Sorge ◽  
...  
Keyword(s):  
2013 ◽  
Author(s):  
Sanjay Andola ◽  
Ram Niranjan ◽  
A. M. Shaikh ◽  
R. K. Rout ◽  
T. C. Kaushik ◽  
...  

2008 ◽  
Vol 79 (7) ◽  
pp. 073301 ◽  
Author(s):  
A. Mančić ◽  
J. Fuchs ◽  
P. Antici ◽  
S. A. Gaillard ◽  
P. Audebert

2018 ◽  
Vol 89 (10) ◽  
pp. 10F123 ◽  
Author(s):  
J. P. Holder ◽  
N. Izumi ◽  
M. Beach ◽  
M. J. Ayers ◽  
P. Bell ◽  
...  

1999 ◽  
Vol 85 (2) ◽  
pp. 169-173 ◽  
Author(s):  
Masao KIMURA ◽  
Muneyuki IMAFUKU ◽  
Masao KUROSAKI ◽  
Siro FUJII ◽  
Yasuhide MORIMOTO

1997 ◽  
Vol 30 (1) ◽  
pp. 16-20 ◽  
Author(s):  
A. Gibaud ◽  
D. Harlow ◽  
J. B. Hastings ◽  
J. P. Hill ◽  
D. Chapman

The technique of high-energy monochromatic Laue X-ray scattering using image plates to record the diffraction patterns is presented. A tunable wiggler beamline is used as an X-ray source. It is shown that such experimental conditions present many advantages over conventional tube sources and photographic films. A study of diffuse scattering in the perovskite compound KMnF3 is presented to illustrate this in a qualitative way.


2009 ◽  
Vol 42 (5) ◽  
pp. 749-757 ◽  
Author(s):  
Clive Wilkinson ◽  
Mogens S. Lehmann ◽  
Flora Meilleur ◽  
Matthew P. Blakeley ◽  
Dean A. A. Myles ◽  
...  

A method to measure the overall gain and point-spread function of an image-plate detector system (converter, phosphor, readout electronics) online from single-crystal diffraction patterns is derived. Only with a knowledge of these quantities can one estimate without bias the true standard deviations of the observed integrated intensities of Bragg reflections measured with such a detector. The gain corrected for the point-spread function should ideally be approximately 1.0 to avoid loss of data or precision due to the upper and lower limits of digitization of the diffraction patterns. The gain and the point-spread function are derived for several configurations of the three neutron Laue image-plate diffractometers, LADI, VIVALDI and LADI-III, at the Institut Laue–Langevin. The detective quantum efficiencies (DQE) of these instruments have been measured to be 0.16 (1), 0.57 (2) and 0.46 (3), respectively. It has also been found that the DQE is effectively constant for different times of exposure, despite the fading of the photostimulated luminescent signal during that time. While the results described in this paper concern neutron detection by image plates, the method is equally valid for other integrating detectors and radiations,e.g.CCD detectors and X-rays.


1993 ◽  
Author(s):  
Clive Wilkinson ◽  
Andre Gabriel ◽  
Mogens Lehmann ◽  
Thomas Zemb ◽  
Frederique Ne
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document