The Radioactivity in Plasma and the Radiation Dose to the Blood after Treatment of Thyroid Carcinoma with Radioiodine

1961 ◽  
Vol 1 (03) ◽  
pp. 280-298
Author(s):  
G. M. Dyche ◽  
D. M. Taylor

SummaryThe variation with time of the radioactivity in plasma has been studied for 15 patients after a total of 32 treatment doses of radioiodine. Blood radiation doses have been estimated and, for patients receiving successive treatments, the cumulative blood radiation dose is calculated. The variation with time of the proportion of radioactivity in three components of the plasma has also been studied.The treatments have been divided into three groups. The first includes all initial or “ablating“ doses and the other two all subsequent doses divided according to the shape of the plasma activity curves. These shapes and the blood radiation doses have been discussed and summarised for each group. Details are given of three cases showing unusually high blood radiation doses.The significance of the “thyroid-protein“ fraction in the plasma and its relation to tissue damage is discussed.

1969 ◽  
Vol 08 (04) ◽  
pp. 339-348
Author(s):  
René. Cárdenas ◽  
Juan. Oliva

SummaryThirty-four women with single autonomous “hot” nodules of the thyroid were treated with 131I. There was a variable degree of thyrotoxicosis in 26 cases while in 3 others there was only local cervical discomfort. The total amount administered varied between 2 and 80 mCi of 131I and the radiation dose to the thyroid from 2 to 450 krads. The nodule and symptoms disappeared in 14 of the patients, while in the other 14 the lesion decreased in size and the clinical manifestations improved. Only in six patients was the result unsatisfactory, without change in the size of the nodule. Results are analysed on the basis of the quantity of radioiodine administered.Modifications of the scintigram before and after treatment are discussed, observing that the “cooling” of the nodule and the reappearance of the surrounding gland are signs of good prognosis.A case is described in which the therapy failed and a thyroid carcinoma was found after surgical resection. Two cases of the series in which there were slight transitory manifestations of post-therapeutic hypothyroidism are also reported.


1965 ◽  
Vol 05 (01) ◽  
pp. 56-67
Author(s):  
I. Pál ◽  
J. Földes ◽  
I. Krasznai

SummaryThe authors investigated the use of 197Hg EDTA complex for kidney scanning. They describe the physical, biological and toxicological properties of the compound; its distribution within the organism, its excretion with urine and faeces and its uptake by the kidneys. The authors have established that the renal cortex selectively secretes the material which makes it suitable for kidney scanning. Some scintigrams of both normal and pathologic kidneys are presented.Finally a detailed discussion of the dosimetry is included. The radiation doses due to 197Hg EDTA are compared with those due to 203Hg-neohydrin and to intravenous pyelography. This comparison shows clearly that the use of 197Hg EDTA considerably decreases the radiation dose to the patient.


2010 ◽  
Vol 6 (1) ◽  
pp. 15
Author(s):  
James P Earls ◽  
Jonathon A Leipsic ◽  
◽  

Recent reports have raised general awareness that cardiac computed tomography (CT) has the potential for relatively high effective radiation doses. While the actual amount of risk this poses to the patient is controversial, the increasing concern has led to a great deal of research on new CT techniques capable of imaging the heart at substantially lower radiation doses than was available only a few years ago. Methods of dose reduction include optimised selection of user-defined parameters, such as tube current and voltage, as well as use of new technologies, such as prospective triggering and iterative reconstruction. These techniques have each been shown to lead to substantial reduction in radiation dose without loss of diagnostic accuracy. This article will review the most frequently used and widely available methods for radiation dose reduction in cardiac CT and give practical advice on their use and limitations.


1979 ◽  
Vol 44 (6) ◽  
pp. 1828-1834
Author(s):  
Asja Šiševa ◽  
Jiřina Slaninová ◽  
Tomislav Barth ◽  
Stephan P. Ditzov ◽  
Luben M. Sirakov

Isoelectric focusing on polyacrylamide gel columns of three native crystalline commercial preparations of insulin and 125I-labelled insulin was carried out. All the compounds studied contained three components of different isoelectric points. The largest fraction, having pI 5.60 ± 0.05, was common to all preparations. The other two fractions were situated in the acid region of pH between pI 4.5 and 5.2. The presence of these fractions is explained by the contamination of crystalline insulins by proinsulin and by the formation of des-amido derivatives during the dissolving and storage of insulin samples, and, in case of labelled insulin, also by the presence of heavily iodinated insulin and contaminating components. The isoelectric focusing of the complex 125I-insulin-antibody showed a peak of radioactivity having pI 6.15 ± 0.05.


Author(s):  
Areo G. Saffarzadeh ◽  
Maureen Canavan ◽  
Benjamin J. Resio ◽  
Samantha L. Walters ◽  
Kaitlin M. Flores ◽  
...  

Hand ◽  
2021 ◽  
pp. 155894472199425
Author(s):  
Kiran R. Madhvani ◽  
Matthew J. R. Clark ◽  
Alex A. J. Kocheta

Background: Diagnostic reference levels are radiation dose levels in medical radiodiagnostic practices for typical examinations for groups of standard-sized individuals for broadly defined types of equipment. This study aimed to contribute to national diagnostic reference levels for common hand and wrist procedures using mini C-arm fluoroscopy. Small joint and digital fracture procedure diagnostic reference levels have not been reported in significant numbers previously with procedure-level stratification. Methods: Data were collected from fluoroscopy logbooks and were cross-referenced against the audit log kept on fluoroscopy machines. A total of 603 procedures were included. Results: The median radiation dose for wrist fracture open fixation was 2.73 cGycm2, Kirschner wiring (K-wiring) procedures was 2.36 cGycm2, small joint arthrodesis was 1.20 cGycm2, small joint injections was 0.58 cGycm2, and phalangeal fracture fixation was 1.05 cGycm2. Conclusions: Wrist fracture fixation used higher radiation doses than phalangeal fracture fixation, arthrodeses, and injections. Injections used significantly less radiation than the other procedures. There are significant differences in total radiation doses when comparing these procedures in hand and wrist surgery. National and international recommendations are that institutional audit data should be collected regularly and should be stratified by procedure type. This study helps to define standards for this activity by adding to the data available for wrist fracture diagnostic reference levels and defining standards for digital and injection procedures.


2014 ◽  
Vol 880 ◽  
pp. 53-56 ◽  
Author(s):  
Sergei Stuchebrov ◽  
Andrey Batranin ◽  
Dan Verigin ◽  
Yelena Lukyanenko ◽  
Maria Siniagina ◽  
...  

Two setups for X-ray visualization of objects interior structure were designed and assembled in TPU. These radiographic systems are based on linear gas-discharge and GaAs semiconductor detectors. During investigation of biological object control of radiation doses has a high priority. In this report radiation dose calculations in X-ray visualization are presented. These calculation also includes dose calculations of sinograms which are used for reconstruction of tomography slices.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Richard G. Kavanagh ◽  
John O’Grady ◽  
Brian W. Carey ◽  
Patrick D. McLaughlin ◽  
Siobhan B. O’Neill ◽  
...  

Magnetic resonance imaging (MRI) is the mainstay method for the radiological imaging of the small bowel in patients with inflammatory bowel disease without the use of ionizing radiation. There are circumstances where imaging using ionizing radiation is required, particularly in the acute setting. This usually takes the form of computed tomography (CT). There has been a significant increase in the utilization of computed tomography (CT) for patients with Crohn’s disease as patients are frequently diagnosed at a relatively young age and require repeated imaging. Between seven and eleven percent of patients with IBD are exposed to high cumulative effective radiation doses (CEDs) (>35–75 mSv), mostly patients with Crohn’s disease (Newnham E 2007, Levi Z 2009, Hou JK 2014, Estay C 2015). This is primarily due to the more widespread and repeated use of CT, which accounts for 77% of radiation dose exposure amongst patients with Crohn’s disease (Desmond et al., 2008). Reports of the projected cancer risks from the increasing CT use (Berrington et al., 2007) have led to increased patient awareness regarding the potential health risks from ionizing radiation (Coakley et al., 2011). Our responsibilities as physicians caring for these patients include education regarding radiation risk and, when an investigation that utilizes ionizing radiation is required, to keep radiation doses as low as reasonably achievable: the “ALARA” principle. Recent advances in CT technology have facilitated substantial radiation dose reductions in many clinical settings, and several studies have demonstrated significantly decreased radiation doses in Crohn’s disease patients while maintaining diagnostic image quality. However, there is a balance to be struck between reducing radiation exposure and maintaining satisfactory image quality; if radiation dose is reduced excessively, the resulting CT images can be of poor quality and may be nondiagnostic. In this paper, we summarize the available evidence related to imaging of Crohn’s disease, radiation exposure, and risk, and we report recent advances in low-dose CT technology that have particular relevance.


Author(s):  
N. Gunko ◽  
◽  
O. Ivanova ◽  
K. Loganovsky ◽  
N. Korotkova ◽  
...  

Background. Radiation accidents at the Chornobyl Nuclear Power Plant (USSR, 1986) and Fukushima-1 (Japan, 2011) have shown that global environmental contamination is an intervention in normal human life making negative effect on population health. These accidents highlighted a number of statutory and regulatory both with medical and social problems for individuals, who returned voluntarily for permanent residence in the Chornobyl Exclusion Zone i.e. a radiation-hazardous area (they are named the «self-settlers»). Objective: generalization of experience in the settlement of normative-legal, ecological-dosimetric and medicosocial life issues of population living in the Chornobyl NPP (ChNPP) Exclusion Zone («self-settlers»). Object and methods. The chosen problem is complex, necessitating the generalization of radiation-hygienic, medical-biological, socio-economic, demographic and sociological research results obtained by the national and foreign authors. A set of theoretical research and analysis of empirical data methods on the principles of interdisciplinary interaction was used; the systematic, legal, economic, medical-biological, demographic and retrospective-dosimetric approaches of research were applied. Results. It was shown that a part of population refused to evacuate or had returned for permanent residence to the radiation-hazardous lands after the ChNPP accident. In 1986–2009 the number of «self-settlers» ranged from 150 to 2,000 in different years. In 2021 – the 101 people. Those were mainly people of working age, mostly females, single people or widows/widowers. Рrevious medical and dosimetric studies have shown that long-term residence in the Exclusion Zone affects physical and mental health of «self-settlers» and causes atypical aging, including involvement of the central nervous system. According to calculations, the average effective total radiation dose accumulated by «self-settlers» for the first 3 years was 30 % of dose for the entire post-accident period, and the dose accumulated over 20 years was 54 % of the dose accumulated over 35 years. But the effective radiation doses accumulated in different periods after the accident differ significantly in residents of different Exclusion Zone settlements. This information needs further study in terms of the «radiation dose - health status» dependence. Conclusions. The effective radiation doses accumulated in different periods after the accident differ significantly in the residents of different Exclusion Zone settlements. Тhe average effective total radiation dose accumulated by «self-settlers» for the first 3 years was 30 % of the dose for the entire post-accident period, and the dose accumulated over 20 years was 54 % of the dose accumulated over 35 years. The Scientific Council meeting of NAMS approved the NRCRM Annual Report. Key words: Chornobyl Nuclear Power Plant, Exclusion Zone, «self-settlers», radiation doses, health.


K ta Kita ◽  
2018 ◽  
Vol 6 (1) ◽  
pp. 73-80
Author(s):  
Felicia Regina Prayogo

This study is about teacher’s roles and students’ attitudes in Freedom Writersmovie. There two objectives of this study which is to find teacher’s roles and students’ attitudes. The subject of the data are the teacher named Erin Gruwell and the students inside the classroom. The theory used in this study was the theory from Harmer (2001) that explained about teacher’s roles, and the other theory was from Brown (2007) and Wenden (1991) about the students’ attitudes. The findings revealed that teacher’ roles have effect on the attitudes of the students whether the attitude is positive or negative from three components: cognitive, behavioral, and evaluative. Finally, the writer concluded that students’ attitudes depend on the teacher’s roles. 


Sign in / Sign up

Export Citation Format

Share Document