ENDOSCOPIC SUBMUCOSAL DISSECTION (ESD) FOR EARLY BARRETT'S CANCER – DOES R0 RESECTION MATTER?

2018 ◽  
Author(s):  
S Subramaniam ◽  
A Alkandari ◽  
S Thayalasekaran ◽  
G Longcroft-Wheaton ◽  
P Bhandari
2020 ◽  
Vol 08 (12) ◽  
pp. E1832-E1839
Author(s):  
Yuichiro Kuroki ◽  
Toshiyuki Endo ◽  
Kenta Iwahashi ◽  
Naoki Miyao ◽  
Reika Suzuki ◽  
...  

Abstract Background and study aims Sessile serrated lesions (SSL) are major precursor lesions of serrated pathway cancers, and appropriate treatment may prevent interval colorectal cancer. Studies have reported the outcomes of endoscopic mucosal resection (EMR) for SSL; however, there are insufficient reports on endoscopic submucosal dissection (ESD). We examined the characteristics and outcomes of SSL and compared them to those of non-SSL in ESD. Patients and methods We reviewed 370 consecutive cases in 322 patients who underwent colorectal ESD between January 2016 and March 2020 at our hospital. There were 267 0-IIa lesions that were stratified into 41 SSL and 226 non-SSL (intramucosal cancer, adenoma) cases. We used propensity matching to adjust for the variances in the factors affecting treatment between the SSL and non-SSL groups. Results In the baseline cases, young women and proximal colon tumor location were significantly more common in the SSL group. There were no statistically significant differences between the SSL and non-SSL groups in terms of en bloc resection rate (97.6 % vs. 99.6 %; P = 0.28), R0 resection rate (92.7 % vs. 93.4 %; P = 0.74), perforation (0 % vs. 0.9 %; P > 0.99), and postoperative bleeding (2.4 % vs. 1.8 %; P = 0.56). Thirty-eight pairs were matched using propensity score, and the median dissection speed (12 vs. 7.7 cm2/h; P = 0.0095) was significantly faster in the SSL than in the non-SSL group. Conclusions ESD for SSL was safely performed, and SSL was smoother to remove than non-SSL. ESD might be an acceptable endoscopic treatment option for SSL.


2021 ◽  
pp. 603-609
Author(s):  
Akiko Sasaki ◽  
Chikamasa Ichita ◽  
Chihiro Sumida ◽  
Karen Kimura ◽  
Takashi Nishino ◽  
...  

Endoscopic resection, particularly endoscopic submucosal dissection (ESD), for colorectal cancers enables a precise pathological diagnosis and safe R0 resection. The recurrence rate after ESD is generally extremely low, with annual surveillance colonoscopy recommended. However, surveillance may not be considered for super-elderly patients owing to their condition. This is a case report of an 85-year-old man in whom curative resection was achieved for an intramucosal adenocarcinoma with ESD. The patient presented with a hypoechoic mass located in his lower right abdomen, diagnosed via surveillance abdominal ultrasound. He had undergone curative ESD for intramucosal cecal cancer 2 years prior. Colonoscopy revealed a type 2 epithelial tumor at the proximal aspect of the ESD scar. Ileocolic resection with lymph node dissection was performed. An epithelial tumor and well-differentiated adenocarcinoma but not a submucosal tumor was detected in the mucosal layer. The lesion was diagnosed not as a local recurrence after ESD but as a newly emerged original advanced cancer. After ESD for colorectal cancer, a newly developed advanced cancer may occur at the site of the ESD scar in a shorter term than usual. Surveillance colonoscopy after ESD is necessary even for super-elderly patients.


Author(s):  
João Santos-Antunes ◽  
Margarida Marques ◽  
Rui Morais ◽  
Fátima Carneiro ◽  
Guilherme Macedo

<b><i>Introduction:</i></b> Endoscopic submucosal dissection (ESD) is a well-established endoscopic technique for the treatment of gastrointestinal lesions. Colorectal ESD outcomes are less reported in the Western literature, and Portuguese data are still very scarce. Our aim was to describe our experience on colorectal ESD regarding its outcomes and safety profile. <b><i>Methods:</i></b> We conducted a retrospective evaluation of recorded data on ESDs performed between 2015 and 2020. Only ESDs performed on epithelial neoplastic lesions were selected for further analysis. <b><i>Results:</i></b> Of a total of 167 colorectal ESDs, 153 were included. Technical success was achieved in 147 procedures (96%). The lesions were located in the colon (<i>n</i> = 24) and rectum (<i>n</i> = 123). The en bloc resection rate was 92% and 97%, the R0 resection rate was 83% and 82%, and the curative resection rate was 79% and 78% for the colon and the rectum, respectively. The need for a hybrid technique was the only risk factor for piecemeal or R1 resection. We report a perforation rate of 3.4% and a 4.1% rate of delayed bleeding; all the adverse events were manageable endoscopically, without the need of blood transfusions or surgery. Most of the lesions were laterally spreading tumours of the granular mixed type (70%), and 20% of the lesions were malignant (12% submucosal and 8% intramucosal cancer). <b><i>Conclusion:</i></b> Our series on colorectal ESD reports a very good efficacy and safety profile. This technique can be applied by endoscopists experienced in ESD.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Satoshi Abiko ◽  
Soichiro Oda ◽  
Akimitsu Meno ◽  
Akane Shido ◽  
Sonoe Yoshida ◽  
...  

Abstract Background Methods have been developed for preventing delayed bleeding (DB) after gastric endoscopic submucosal dissection (GESD). However, none of the methods can completely prevent DB. We hypothesized that DB could be prevented by a modified search, coagulation, and clipping (MSCC) method for patients at low risk for DB and by combining the use of polyglycolic acid sheets and fibrin glue with the MSCC method (PMSCC method) for patients at high risk for DB (antibleeding [ABI] strategy). This study assessed the technical feasibility of this novel strategy. Method We investigated 123 lesions in 121 consecutive patients who underwent GESD in Kushiro Rosai Hospital between April 2018 and January 2020. The decision for continuation or cessation of antithrombotic agents was based on the Guidelines for Gastroenterological Endoscopy in Patients Undergoing Antithrombotic Treatment. Results Oral antithrombotic agents were administered to 28 patients (22.8%). The en bloc R0 resection rate was 98.4%. The MSCC method and the PMSCC method for preventing DB were performed in 114 and 9 lesions, respectively. The median time of the MSCC method was 16 min, and the median speed (the resection area divided by the time of method used) was 3.6 cm2/10 min. The median time of the PMSCC method was 59 min, and the median speed was 1.3 cm2/10 min. The only delayed procedural adverse event was DB in 1 (0.8%) of the 123 lesions. Conclusions The ABI strategy is feasible for preventing DB both in patients at low risk and in those at high risk for DB after GESD, whereas the PMSCC method may be necessary for reduction of time.


2018 ◽  
Vol 06 (11) ◽  
pp. E1340-E1348 ◽  
Author(s):  
Carl-Fredrik Rönnow ◽  
Noriya Uedo ◽  
Ervin Toth ◽  
Henrik Thorlacius

Abstract Background and study aims Endoscopic submucosal dissection (ESD) allows en bloc resection of large colorectal lesions but ESD experience is limited outside Asia. This study evaluated implementation of ESD in the treatment of colorectal neoplasia in a Western center. Patients and methods Three hundred and one cases of colorectal ESD (173 rectal and 128 colonic lesions) were retrospectively evaluated in terms of outcome, learning curve and complications. Results Median size was 4 cm (range 1 – 12.5). En bloc resection was achieved in 241 cases amounting to an en bloc resection rate of 80 %. R0 resection was accomplished in 207 cases (69 %), RX and R1 were attained in 83 (27 %) and 11 (4 %) cases, respectively. Median time was 98 min (range 10 – 588) and median proficiency was 7.2 cm2/h. Complications occurred in 24 patients (8 %) divided into 12 immediate perforations, five delayed perforations, one immediate bleeding and six delayed bleedings. Six patients (2 %), all with proximal lesions, had emergency surgery. Two hundred and four patients were followed up endoscopically and median follow-up time was 13 months (range 3 – 53) revealing seven recurrences (3 %). En bloc rate improved gradually from 60 % during the first period to 98 % during the last period. ESD proficiency significantly improved between the first study period (3.6 cm2/h) and the last study period (10.8 cm2/h). Conclusions This study represents the largest material on colorectal ESD in the west and shows that colorectal ESD can be implemented in clinical routine in western countries after appropriate training and achieve a high rate of en bloc and R0 resection with a concomitant low incidence of complications. ESD of proximal colonic lesions should be attempted with caution during the learning curve because of higher risk of complications.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Wen-Hsin Hsu ◽  
Meng-Shun Sun ◽  
Hoi-Wan Lo ◽  
Ching-Yang Tsai ◽  
Yu-Jou Tsai

Objectives. Endoscopic submucosal dissection (ESD) for early colorectal neoplasms is regarded as a difficult technique and should commence after receiving the experiences of ESD in the stomach. The implementation of colorectal ESD in countries where early gastric cancer is uncommon might therefore be difficult. The aim is to delineate the feasibility and the learning curve of colorectal ESD performed by a colonoscopist with limited experience of gastric ESD.Methods. The first fifty cases of colorectal ESD, which were performed by a single colonoscopist between July 2010 and April 2013, were enrolled.Results. The mean of age was 64 (±9.204) years with mean size of neoplasm at 33 (±12.63) mm. The mean of procedure time was 70.5 (±48.9) min. The rates ofen blocresection, R0 resection, and curative resection were 86%, 86%, and 82%, respectively. Three patients had immediate perforation, but no patient developed delayed perforation or delayed bleeding.Conclusion. Our result disclosed that it is feasible for colorectal ESD to be performed by a colonoscopist with little experience of gastric ESD through satisfactory training and adequate case selection.


2019 ◽  
Vol 07 (05) ◽  
pp. E664-E671 ◽  
Author(s):  
Victoria Jimenez-Garcia ◽  
Masayoshi Yamada ◽  
Hiroaki Ikematsu ◽  
Hiroyuki Takamaru ◽  
Seiichiro Abe ◽  
...  

Abstract Background and study aims Surgery is the standard treatment for colon tumors associated with diverticulum. Use of endoscopic submucosal dissection (ESD) to treat such tumors is controversial. The aim of this study was to assess the safety and feasibility of ESD in treating superficial colorectal tumors situated near or involving diverticulum. Patients and methods Consecutive patients from two referral centers who had colorectal tumors near or involving diverticulum treated by ESD were retrospectively studied. Clinicopathological characteristics and clinical outcomes were analyzed. Results Of the 12 patients studied, six had tumors near diverticulum and six had tumors involving diverticulum. The overall en-bloc R0 resection rate, median tumor size and procedure time were 67 %, 26.5 mm (range, 15 – 80 mm) and 110 minutes (range, 50 – 220 minutes), respectively. For tumors near diverticulum group, the en-bloc R0 resection rate was 100 % and no adverse events (AEs) or residual/recurrent tumors were observed. In contrast, for intradiverticular tumors group, the en-bloc R0 resection rate was low at 33 %, and one AE (perforation) was observed. The diverticula were ≥ 6 mm in diameter in the patients with incomplete resection. However, all but one diverticulum was unrecognized before ESD. Two residual tumors were detected at the 12-month surveillance and one required surgery. Conclusions This case series indicates that ESD is safe and feasible for treating colorectal tumors near a diverticulum and might be feasible for tumors involving a diverticulum smaller than 6 mm. Selection for smaller diverticulum size may contribute to higher en-bloc R0 resection rates.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Hiroaki Matsui ◽  
Naoto Tamai ◽  
Toshiki Futakuchi ◽  
Shunsuke Kamba ◽  
Akira Dobashi ◽  
...  

Abstract Background Endoscopic submucosal dissection (ESD) is technically difficult and requires considerable training. The authors have developed a multi-loop traction device (MLTD), a new traction device that offers easy attachment and detachment. We aimed to evaluate the utility of MLTD in ESD. Methods This ex vivo pilot study was a prospective, block-randomized, comparative study of a porcine stomach model. Twenty-four lesions were assigned to a group that undertook ESD using the MLTD (M-ESD group) and a group that undertook conventional ESD (C-ESD group) to compare the speed of submucosal dissection. In addition, the data of consecutive 10 patients with eleven gastric lesions was collected using electronic medical records to clarify the inaugural clinical outcomes of gastric ESD using MLTD. Results The median (interquartile range) speed of submucosal dissection in the M-ESD and C-ESD groups were 141.5 (60.9–177.6) mm2/min and 35.5 (20.8–52.3) mm2/min, respectively; submucosal dissection was significantly faster in the M-ESD group (p < 0.05). The rate of en bloc resection and R0 resection was 100% in both groups, and there were no perforation in either group. The MLTD attachment time was 2.5 ± 0.9 min and the MLTD extraction time was 1.0 ± 1.1 min. Clinical outcomes of MLTD in gastric ESD were almost the same as those of ex vivo pilot study. Conclusions MLTD increased the speed of submucosal dissection in ESD and was similarly effective when used by expert and trainee endoscopists without perforation. MLTD can potentially ensure a safer and faster ESD.


Sign in / Sign up

Export Citation Format

Share Document