How Do Transcatheter Heart Valves Fit in Mitral Annuloplasty Rings and Which Combination Can be Recommended?

2018 ◽  
Vol 67 (04) ◽  
pp. 257-265
Author(s):  
Roya Ostovar ◽  
Ralf-Uwe Kuehnel ◽  
Michael Erb ◽  
Martin Hartrumpf ◽  
Thomas Claus ◽  
...  

Background Transcatheter heart valve (THV) as valve-in-ring is increasingly used in the mitral position. Semi-rigid rings may serve as a more appropriate scaffold for proper anchoring of a THV as they may change from their oval to a round shape thereby fitting to the implanted THV. Methods One rigid and five semi-rigid rings of four manufacturers, Edwards Physio I and II, Sorin 3D Memo, Medtronic Simulus, and St. Jude Medical (SJM) Saddle and SJM Sequin, with sizes 28 to 36 mm and Edwards Sapien III THV 23, 26, and 29 mm were used. Preevaluation comprised insertion/inflation of the THV into the ring and visual inspection for the paravalvular gap ≥ 4 mm2. Only valves not showing paravalvular gap were then submitted to hemodynamic evaluation with a pulse duplicator. Cusp movement was assessed with a high-speed-camera. Mean transvalvular gradients (TVGs) were measured. Results SJM Saddle ring of all sizes and SJM Sequin ring 34 showed marked gaps combined with all THV sizes, thus not undergoing hemodynamic testing. It was further shown that ring sizes ≥ 36 mm did not allow for a proper fit of even the largest THV into the ring of all the manufacturers and were consequently not hemodynamically evaluated. The 23 mm THV was too small for any ring size. The lowest gradients were achieved with the 26 mm THV in 30 and 32 mm and the 29 mm THV in 32 and 34 mm rings. Conclusion Not all currently available annuloplasty rings are ideal scaffolds for THV placement. It appears that a more proper fit can be achieved with semi-rigid rings than with rigid ones. Note that 23 mm THV appeared to be too small for an adequate anchoring in even the smallest available ring. Thus, 26 mm as well as 29 mm THV fit properly in ring sizes between 28 and 34 mm. Surgeons may consider to choose from those ring brands and sizes which allow for good placement of a THV in view of possible valve degeneration in the later course.

1995 ◽  
Vol 18 (7) ◽  
pp. 380-391 ◽  
Author(s):  
V. Garitey ◽  
T. Gandelheid ◽  
J. Fuseri ◽  
R. PÉlissier ◽  
R. Rieu

To characterise hydrodynamic properties of prosthetic heart valves in mitral position, ultrasonic velocity measurements were performed using a cardiovascular simulator. A Duromedics and a Saint-Jude Medical bileaflet heart valve were tested. The Saint-Jude valve was oriented first in an anatomical position, i.e. the tilt axis parallel to the septal wall, and then in an anti-anatomical position. In the anti-anatomical position, from mid diastole to mid systole, two contrarotative vortices are generated in the ventricle by the interaction between the flow directed by the leaflets downstream from the lateral orifices and the ventricular wall motions. In the anatomical position, the mitral flow penetrates the ventricle principally through the lateral orifice proximal to the septal wall, due to the vortex in the atrial chamber. The mitral inflow then circulates along the septal wall to the apex, and produces a large ventricular vortex during systole. In the anatomical position, the Saint-Jude thus provides a better ventricular washout during this phase. The mitral inflow through the Duromedics in the anti-anatomical position produces two contrarotative vortices in the ventricle, but in the opposite sense than downstream the Saint-Jude valve; the flows that penetrate through the lateral orifices are directed to the ventricular walls and then recirculate to the centre of the ventricle, providing a very fluctuating flow near the apex. Thus, a slight difference in valve design produces a significant difference in the ventricular flow fields.


1981 ◽  
Vol 29 (05) ◽  
pp. 307-311 ◽  
Author(s):  
M. Gottwik ◽  
T. Fentrop ◽  
K. Kobel ◽  
S. Langsdorf ◽  
M. Schlepper ◽  
...  

2000 ◽  
Author(s):  
Toshinosuke Akutsu ◽  
Daiki Higucchi ◽  
Tomohiro Taguchi

Abstract Four typical mechanical bileaflet heart valves (St. Jude Medical, Advancing The Standard, Carbomedics, and Jyros valves) have been tested in the mitral position under pulsatile flow conditions. Measurements of velocity and turbulent stresses were conducted at five downstream locations using a sophisticated cardiac simulator in conjunction with a highly sensitive two-component LDA. Comparison of these flow fields associated with the opening and subsequent accelerating phase of the flow revealed similarity and dissimilarity of the flow field associated with the different valve designs and helped established visualizing the effect of the valve designs and orientations on the flow.


1987 ◽  
Vol 16 (2) ◽  
pp. 77-85 ◽  
Author(s):  
R Heiliger

In order to determine the effectiveness of mechanical heart valves two different types of mechanical heart valves, three tilting disc valves (BS–SD, BS–CCD, BS–M) and two bileaflet valves (St Jude Medical, Duromedics) with the same size of annulus diameter dA = 29 mm have been investigated in the mitral position of a mock circulation under pulsatile flow conditions. Flow, pressure and orifice area have been measured. Insufficiency, mean orifice area, discharge coefficient, performance index, and efficiency index have been calculated. The investigated tilting disc valves show smaller reflux volume and smaller insufficiency when comparing with the bileaflet valves. The bileaflet valves show higher values of orifice areas—that is to say smaller pressure drops—than the tilting disc valves. The St Jude Medical shows the biggest orifice areas, but also the highest reflux volume and insufficiency. Insufficiency of the Duromedics is slightly higher than that of the tilting disc valves. The orifice area of the Duromedics is bigger than that of the tilting disc valves and smaller than that of the St Jude Medical. The different pivot and the different profile of the disc of the BS–CCD and the BS–M are responsible for the more constant behaviour of the opening of these tilting disc valves when comparing with the BS–SD. Though the bileaflet valves show the better efficiency index, none of the valve types is superior in all hydrodynamic criteria. Both valve types, the bileaflet valves and the tilting disc valves, show different hydrodynamic advantages and disadvantages.


1993 ◽  
Vol 16 (7) ◽  
pp. 515-520 ◽  
Author(s):  
C. Kingsbury ◽  
R. Kafesjian ◽  
G. Guo ◽  
P. Adlparvar ◽  
J. Unger ◽  
...  

A total of 15 bileaflet mechanical heart valves were studied in a pulse duplicator at the Helmholtz Institute (Aachen, Germany) under conditions approximating first, a physiological pressure curve and subsequently, a sinusoidal pressure curve. In this study Edwards-Duromedics valves of the modified specification were compared with the earlier version of the Edwards-Duromedics valve as well as with St. Jude Medical valves. Each valve was tested at a series of nine (9) conditions. At each condition, without altering the valve installation or the systemic conditions, each valve was filmed by two separate video systems: the Helmholtz Institute strobe light system and a high speed video recording system. All data, as recorded by each system, was then independently analyzed by both of the two contributing groups and subsequently compared. In this manner, it was possible to objectively verify not only the consistency of the data obtained, but to also determine the relative reliability of the methods for cavitation threshold detection.


2017 ◽  
Vol 124 ◽  
pp. 01006
Author(s):  
Yan-guo Wang ◽  
Dapeng Xie ◽  
Haiying Wang ◽  
Xiangdong Li ◽  
Jing Shi ◽  
...  
Keyword(s):  

Author(s):  
Gry Dahle ◽  
Arnt E. Fiane ◽  
Kjell-Arne Rein

A 71-year-old woman with severe congestive heart failure and failed mitral valve repair was referred for surgery. Because of her low ejection fraction, a valve-in-ring procedure was suggested. There was a great difference in the given size for the 34-mm Carpentier-Edwards-Physio-Ring and the biggest available transcatheter valve of 29 mm from Edwards. Therefore, we did a “bench test.” We expanded a 29-mm Edwards SAPIEN-XT aortic valve in a 34-mm Carpentier-Edwards-Physio-Ring. It fitted well and turned out circular with good coaptation of the leaflets. Thereafter, a successful transapical mitral valve-in-ring implantation on cardiopulmonary bypass was performed, and additional leads for cardiac resynchronization was placed.


ASVIDE ◽  
2016 ◽  
Vol 3 ◽  
pp. 420-420
Author(s):  
Khalil Ahmad ◽  
Kaj Erik Klaaborg ◽  
Vibeke Hjortdal ◽  
Bjarne Linde Nørgaard ◽  
Christian Juhl Terkelsen ◽  
...  

2014 ◽  
Vol 754 ◽  
pp. 122-160 ◽  
Author(s):  
B. Min Yun ◽  
L. P. Dasi ◽  
C. K. Aidun ◽  
A. P. Yoganathan

AbstractProsthetic heart valves have been widely used to replace diseased or defective native heart valves. Flow through bileaflet mechanical heart valves (BMHVs) have previously demonstrated complex phenomena in the vicinity of the valve owing to the presence of two rigid leaflets. This study aims to accurately capture the complex flow dynamics for pulsatile flow through a 23 mm St Jude Medical (SJM) Regent™ BMHV. The lattice-Boltzmann method (LBM) is used to simulate pulsatile flow through the valve with the inclusion of reverse leakage flow at very high spatiotemporal resolution that can capture fine details in the pulsatile BMHV flow field. For higher-Reynolds-number flows, this high spatiotemporal resolution captures features that have not been observed in previous coarse resolution studies. In addition, the simulations are able to capture with detail the features of leaflet closing and the asymmetric b-datum leakage jet during mid-diastole. Novel flow physics are visualized and discussed along with quantification of turbulent features of this flow, which is made possible by this parallelized numerical method.


2012 ◽  
Vol 43 (2) ◽  
pp. 371-377 ◽  
Author(s):  
O. Wendler ◽  
M. Thielmann ◽  
H. Schroefel ◽  
A. Rastan ◽  
H. Treede ◽  
...  