Study of Resistance Distribution and Numerical Modeling of Water Hammer in a Long-Distance Water Supply Pipeline

Author(s):  
Yuebin Wu ◽  
Liang Chi ◽  
Hailong Zhang
Energies ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 108 ◽  
Author(s):  
Wuyi Wan ◽  
Boran Zhang ◽  
Xiaoyi Chen

Water hammer control in water supply pipeline systems is significant for protecting pipelines from damage. The goal of this research is to investigate the effects of pumps moment of inertia design on pipeline water hammer control. Based on the method of characteristics (MOC), a numerical model is established and plenty of simulations are conducted. Through numerical analysis, it is found that increasing the pumps moment of inertia has positive effects both on water hammer control as well as preventing pumps rapid runaway speed. Considering the extra cost of space, starting energy, and materials, an evaluation methodology of efficiency on the increasing moment of inertia is proposed. It can be regarded as a reference for engineers to design the moment of inertia of pumps in water supply pipeline systems. Combined with the optimized operations of the valve behind the pumps, the pipeline systems can be better protected from accident events.


Author(s):  
Jian Zhang ◽  
Xiaodong Yu ◽  
Jianfeng An ◽  
Arash Hazrati

Long-distance water-supply project is an effective way to solve the uneven spatial and temporal distribution of water resources, but the safety of water conveyance system is threatened seriously by water-hammer. Based on the research of the characteristic of water-hammer with pipe friction considered, the formula of indirect water-hammer is deduced and the application scope of the formula is also discussed, which is the theoretical basis for the design of polyline closure law. To the defects that valve closure time is long and response of accident is slow in the long-distance water-supply project, polyline closure law is designed with consideration of valve overflowing property, which greatly reduces the closure time and water-hammer. At the same time, the flow inertia is large in long-distance water-supply project and break point of polyline closure law is hard to fix. In order to improve the reliability of the mechanical operating system, locking device is installed, which make the polyline closure law carry out successfully and provide a new idea for water hammer protection in long-distance water-supply project.


2018 ◽  
Vol 246 ◽  
pp. 01066 ◽  
Author(s):  
Xingtao Wang ◽  
Jian Zhang ◽  
Xiaodong Yu ◽  
Lin Shi

The conventional air vessel installation is usually installed behind the check valve at the upstream end of the pipeline to effectively control the water hammer pressure due to pump trip. However, the water hammer pressure caused by underground pipe burst has been neglected. The water hammer protection of air vessel due to pipe burst in long distance water supply system was discussed in this paper. According to analysis of the process of the pipe burst, the mathematical model of underground pipe burst and air vessel were established. A new air vessel installation that was installed in the middle of the pipeline was proposed. The new air vessel installation was simulated by method of characteristics. Then it was compared with the conventional air vessel when the pump trip and the pipe burst occur respectively. The results show that both the conventional air vessel and the new air vessel can effectively protect the water hammer duo to the pump trip. Moreover, when pipe burst occurs, the conventional air vessel cannot achieve the safe operation of the long distance water supply system. However, under the same air vessel type parameters, the new air vessel installation can effectively protect the water hammer pressure.


2011 ◽  
Vol 90-93 ◽  
pp. 2954-2959
Author(s):  
Yu Si Yang ◽  
Li Liu ◽  
Kun Li

According to the situation of Chinese urban water supply, this article has analyszed the possibility and computing method for water hammer that caused by pump stop in large diameter and high-lift water pipelines. In addition the impact of Full-featured Pump Curve on the water hammer calculation are also discussed. Finally, using the water hammer calculation of the primary pumping stations within a water-supply project which located in northeast China as an example, we had made corresponding conclusion.


2019 ◽  
Vol 68 (6) ◽  
pp. 420-430
Author(s):  
Xingtao Wang ◽  
Jian Zhang ◽  
Xiaodong Yu ◽  
Sheng Chen ◽  
Wenlong Zhao ◽  
...  

Abstract Valves are installed at the end of each branch pipeline in a tree-type long distance gravitational water supply system to regulate flow. However, the sequential closing of all valves may cause a tremendous superposed pressure rise, even larger than the pressure rise under simultaneous valve closure. In this paper, the effects of sequential valve closure on the superposed maximum water hammer pressure rise in a pipeline were investigated. By using the wave superposition principle, a sequential valve closure formula leading to maximum water hammer was proposed and verified using numerical simulation based on a practical project. In addition, the superposed maximum pressure rises in the pipeline were compared under single, simultaneous and sequential valve closure, respectively. The results show that the sequential valve closure formula agrees well with the numerical results and the pressure rise in the pipeline under the sequential closing was the largest. Moreover, compared with the superposed maximum pressure rises at the main pipeline, the effect of sequential valve closure on superposed maximum pressure rise at the branch pipeline is more sensitive.