scholarly journals Investigation of Water Hammer Protection in Water Supply Pipeline Systems Using an Intelligent Self-Controlled Surge Tank

Energies ◽  
2018 ◽  
Vol 11 (6) ◽  
pp. 1450 ◽  
Author(s):  
Wuyi Wan ◽  
Boran Zhang
Energies ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 108 ◽  
Author(s):  
Wuyi Wan ◽  
Boran Zhang ◽  
Xiaoyi Chen

Water hammer control in water supply pipeline systems is significant for protecting pipelines from damage. The goal of this research is to investigate the effects of pumps moment of inertia design on pipeline water hammer control. Based on the method of characteristics (MOC), a numerical model is established and plenty of simulations are conducted. Through numerical analysis, it is found that increasing the pumps moment of inertia has positive effects both on water hammer control as well as preventing pumps rapid runaway speed. Considering the extra cost of space, starting energy, and materials, an evaluation methodology of efficiency on the increasing moment of inertia is proposed. It can be regarded as a reference for engineers to design the moment of inertia of pumps in water supply pipeline systems. Combined with the optimized operations of the valve behind the pumps, the pipeline systems can be better protected from accident events.


2016 ◽  
Vol 19 (1) ◽  
pp. 17-30 ◽  
Author(s):  
Huan-Feng Duan

The transient frequency response (TFR) method has been widely developed and applied in the literature to identify and detect potential defects such as leakage and blockage in water supply pipe systems. This type of method was found to be efficient, economic and non-intrusive for pipeline condition assessment and diagnosis, but its applications so far are mainly limited to single and simple pipeline systems. This paper aims to extend the TFR-based leak detection method to relatively more complex pipeline connection situations. The branched and looped pipe junctions are firstly investigated for their influences to the system TFR, so that their effects can be characterized and separated from the effect of other components and potential leakage defects in the system. The leak-induced patterns of transient responses are derived analytically using the transfer matrix method for systems with different pipe junctions, which thereafter are used for the analysis of pipe leakage conditions in the system. The developed method is validated through different numerical experiments in this study. Based on the analytical analysis and numerical results, the applicability and accuracy as well as the limitations of the developed TFR-based leak detection method are discussed for practical applications in the paper.


2008 ◽  
Author(s):  
Jianyong Hu ◽  
Jian Zhang ◽  
Weihua Lu ◽  
Shibo Ma

One-way surge tank is an important measure of water hammer protection in long water supply engineering. It can control the negative pressure efficiently and prevent pipeline from column separation. Setting one-way surge tank in proper place along pipeline is relative to the safety of long water supply engineering. Principle of Setting one-way surge tank is made through theoretical analysis detailedly. It is obviously that result of theoretical analysis is conservative because attenuation of water hammer is ignored, but theoretical analysis provide an proper approach for setting one-way surge tank. Based on result of theoretical analysis, optimization setting is obtained through numerical simulation.


ICPTT 2011 ◽  
2011 ◽  
Author(s):  
Ming Zhao ◽  
Xiaoxi Han ◽  
Yuequan Bao ◽  
Guoquan Wu ◽  
Congsheng Liu

Author(s):  
Gennadiy Ol'garenko ◽  
Boris Gordon

A method of rain uniformity’s distribution was presented for different spraying devices, which were set on irrigation machines working in different mode of moving. A method for effective irrigation radius and width calculation was justified by using irrigation depth uniformity values from the area under water supply pipeline of the irrigation machine.


2022 ◽  
pp. 1420326X2110564
Author(s):  
Chuanmin Tai ◽  
Guansan Tian ◽  
Wenjun Lei

Condensation is a major issue in the safe operation of utility tunnels. To address the condensation problem, the indoor air temperature, relative humidity (RH) and surface temperature in an urban utility tunnel in Jining were continuously measured, and the condensation conditions were surveyed and analysed. The results indicated that under natural ventilation conditions, the air temperature in the comprehensive cabin varied from 23.4°C to 24.5°C, the RH fluctuated between 86.4% and 95.3%, and the corresponding air dew point temperature (DPT) remained in the range of 22.2°C–22.9°C. The surface temperature of the water supply pipeline ranged from 17.8°C to 18.5°C, which was far lower than the DPT in the tunnel, resulting in serious condensation. A water supply pipeline with an anti-condensation design was developed based on environmental test data. A 25-mm-thick rubber plastic sponge insulation layer was used to thermally insulate the water supply pipeline, preventing further dew condensation. Furthermore, mechanical ventilation had little effect on reducing the RH in the tunnel and may actually cause dew condensation; therefore, a ventilation control mode was proposed in this study. These results are expected to provide basic data for further research and reference for the safe management of utility tunnels.


2013 ◽  
Vol 316-317 ◽  
pp. 723-726
Author(s):  
Jian Qun Jiang ◽  
Xiao Wen Yao ◽  
Yi Ting Lu

Water supply pipeline system is a key issue in urban lifeline engineering, and the seismic assessment for the system damage is of significant importance. In this study, method of seismic damage assessment on underground water supply pipeline is introduced. With emphasis on the uncertainties of earthquake level, ground condition, soil-pipe interaction and capacity to resist pipe deformation in longitudinal direction, the check point method is applied to the reliability study of water pipeline, and a case study is presented to show the implementation of the proposed model.


Sign in / Sign up

Export Citation Format

Share Document