Solvent mediated vibrational relaxation: Superfluid helium droplet spectroscopy of HCN dimer

1999 ◽  
Vol 111 (8) ◽  
pp. 3426-3433 ◽  
Author(s):  
K. Nauta ◽  
R. E. Miller
2015 ◽  
Vol 86 (8) ◽  
pp. 084102 ◽  
Author(s):  
Yunteng He ◽  
Jie Zhang ◽  
Yang Li ◽  
William M. Freund ◽  
Wei Kong

2018 ◽  
Vol 20 (1) ◽  
pp. 118-130 ◽  
Author(s):  
Arnau Vilà ◽  
Miguel Paniagua ◽  
Miguel González

The vibrational relaxation (VER) of a X2 molecule in a 4He superfluid nanodroplet (HeND; 0.37 K) was studied adapting a quantum approach recently proposed by us. In the first theoretical study on the VER of molecules inside HeND the I2 molecule was examined [cascade mechanism (ν → ν − 1; ν − 1 → ν − 2; …) and time scale of ns].


2016 ◽  
Vol 18 (40) ◽  
pp. 28082-28090 ◽  
Author(s):  
Matin Kaufmann ◽  
Daniel Leicht ◽  
Raffael Schwan ◽  
Devendra Mani ◽  
Gerhard Schwaab ◽  
...  

Infrared absorption spectra of glycine and glycine–water aggregates embedded in superfluid helium nanodroplets were recorded in the frequency range 1000–1450 cm−1.


2014 ◽  
Vol 500 (5) ◽  
pp. 052012 ◽  
Author(s):  
S B Emery ◽  
J M Boyle ◽  
K B Rider ◽  
B K Little ◽  
C M Lindsay

2021 ◽  
Vol 154 (13) ◽  
pp. 134303
Author(s):  
Rahul Pandey ◽  
Steven Tran ◽  
Jie Zhang ◽  
Yuzhong Yao ◽  
Wei Kong

Author(s):  
Yoshinori Fujiyoshi

The resolution of direct images of biological macromolecules is normally restricted to far less than 0.3 nm. This is not due instrumental resolution, but irradiation damage. The damage to biological macromolecules may expect to be reduced when they are cooled to a very low temperature. We started to develop a new cryo-stage for a high resolution electron microscopy in 1983, and successfully constructed a superfluid helium stage for a 400 kV microscope by 1986, whereby chlorinated copper-phthalocyanine could be photographed to a resolution of 0.26 nm at a stage temperature of 1.5 K. We are continuing to develop the cryo-microscope and have developed a cryo-microscope equipped with a superfluid helium stage and new cryo-transfer device.The New cryo-microscope achieves not only improved resolution but also increased operational ease. The construction of the new super-fluid helium stage is shown in Fig. 1, where the cross sectional structure is shown parallel to an electron beam path. The capacities of LN2 tank, LHe tank and the pot are 1400 ml, 1200 ml and 3 ml, respectively. Their surfaces are placed with gold to minimize thermal radiation. Consumption rates of liquid nitrogen and liquid helium are 170 ml/hour and 140 ml/hour, respectively. The working time of this stage is more than 7 hours starting from full LN2 and LHe tanks. Instrumental resolution of our cryo-stage cooled to 4.2 K was confirmed to be 0.20 nm by an optical diffraction pattern from the image of a chlorinated copper-phthalocyanine crystal. The image and the optical diffraction pattern are shown in Fig. 2 a, b, respectively.


1978 ◽  
Vol 39 (C6) ◽  
pp. C6-35-C6-36 ◽  
Author(s):  
J. M. Parpia ◽  
D. J. Sandiford ◽  
J. E. Berthold ◽  
J. D. Reppy

Sign in / Sign up

Export Citation Format

Share Document