scholarly journals Reduction of background scattered light in vacuum systems for cold atoms experiments

AIP Advances ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. 105125
Author(s):  
J. Vovrosh ◽  
L. Earl ◽  
H. Thomas ◽  
J. Winch ◽  
B. Stray ◽  
...  
2013 ◽  
Vol 61 (1) ◽  
pp. 18-24 ◽  
Author(s):  
T. Bienaimé ◽  
R. Bachelard ◽  
J. Chabé ◽  
M.T. Rouabah ◽  
L. Bellando ◽  
...  

2020 ◽  
Vol 3 (1) ◽  
Author(s):  
Christopher D. Parmee ◽  
Janne Ruostekoski

Abstract Resonant light interacting with matter supports different phases of a polarisable medium, and optical bistability where two phases coexist. Such phases have previously been actively studied in cavities. Here, we identify signatures of optical phase transitions and optical bistability mapped onto scattered light in free-space planar arrays of cold atoms. Methods on how to explore such systems in superradiant and extreme subradiant states are proposed. The cooperativity threshold and intensity regimes for the intrinsic optical bistability, supported by resonant dipole-dipole interactions alone, are derived in several cases of interest analytically. Subradiant states require lower intensities, but stronger cooperativity for the existence of non-trivial phases than superradiant states. The transmitted light reveals phase transitions and bistability that are predicted by mean-field theory as large jumps in coherent and incoherent signals and hysteresis. In the quantum solution, traces of phase transitions are identified in enhanced quantum fluctuations of excited level populations.


Author(s):  
W. C. Bigelow ◽  
F. B. Drogosz ◽  
S. Nitschke

High vacuum systems with oil diffusion pumps usually have a pressure switch to protect against Insufficient cooling water; however, If left unattended for long periods of time, failure of the mechanical fore pump can occur with equally serious results. The device shown schematically in Fig. 1 has been found to give effective protection against both these failures, yet it is inexpensive and relatively simple to build and operate.With this system, pressure in the fore pump line is measured by thermocouple vacuum gage TVG (CVC G.TC-004) whose output is monitored by meter relay MRy (Weston 1092 Sensitrol) which is set to close if the pressure rises above about 0.2 torr. This energizes control relay CRy (Potter & Brumfield KA5Y 120VAC SPDT) cutting off power to solenoid-operated fore line valve Vf (Cenco 94280-4 Norm. Closed) which closes to prevent further leakage of air into the diffusion pump


2004 ◽  
Vol 116 ◽  
pp. 247-252 ◽  
Author(s):  
Y. Colombe ◽  
B. Mercier ◽  
H. Perrin ◽  
V. Lorent
Keyword(s):  

1987 ◽  
Vol 153 (10) ◽  
pp. 363 ◽  
Author(s):  
Evgenii B. Aleksandrov ◽  
V.S. Zapasskii