pressure switch
Recently Published Documents


TOTAL DOCUMENTS

63
(FIVE YEARS 10)

H-INDEX

5
(FIVE YEARS 1)

2021 ◽  
Vol 35 (4) ◽  
pp. 52-57
Author(s):  
Seok-Hun Kim ◽  
Euy-Hong Hwang ◽  
Doon-Mook Choi

Installation of ancillary facilities such as electrical rooms is crucial due to the complicated structure and division of the interior of a complex building. Furthermore, carbon-dioxide extinguishing systems are mainly installed in these ancillary facilities, and the number of systems installed has been increasing annually. Accordingly, the importance of in-house inspection is being emphasized. In this study, the literature and statistics related to the in-house inspection of fire-fighting facilities were reviewed. Based on the results, problems were derived from the overlap between in-house inspection and similar inspection, the installation location of the pressure switch, the installation standard of the air respirator, the safety awareness of people involved, and the technical qualification level of the in-house inspection assistant. Additionally, improvement measures to enact, amend, and establish public notices were proposed for self-inspection systems.


2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Imam Setiadi ◽  
Irwan Kustianto

Kebutuhan air minum serta akses untuk mendapatkan air minum yang sehat menjadi kebutuhan dasar yang harus dipenuhi terutama di daerah-daerah yang rawan air. Terutama  daerah-daerah yang sulit dijangkau atau tidak  mendapat pelayanan air bersih yang disediakan oleh Perusahaan Daerah Air Minum dan lokasi yang secara geografis juga sulit untuk mendapatkan sumber air yang baik. Adanya sarana  penyediaan air bersih dengan sistem ultrafiltrasi dan reverse osmosis yang dikembangkan oleh Pusat Teknologi Lingkungan BPPT memungkinkan untuk diterapkan dilokasi-lokasi sulit mendapatkan air, sehingga masalah kesulitan air dapat teratasi. Hanya saja perlu pengelolaan yang baik, serta operator yang cakap, sehingga alat tersebut dapat beroperasi secara berkesinambungan. Kemudahan dalam mengoperasikan, serta otomatisasi menjadi pertimbangan tersendiri terhadap kemudahan dalam pengoperasian alat tersebut. Jenis pompa  dan peralatan pengontrol tangki-tangki dipilih  agar  masyarakat tidak sulit mencari suku cadangnya.  Untuk mengontrol tangki-tangki air pada sarana penyedia air bersih sistim ultrafiltrasi dan reverse osmosis digunakan teknologi yang sederhana, yaitu radar untuk mengatur tinggi muka air, pressure switch sebagai penunjuk tekanan air, serta PLC Schneider Zelio Smart Relay sebagai pusat kontrolnya. Sistem kontrol radar, pressure switch dan PLC schneider zelio smart relay berharga murah, mudah dalam penerapanya dan dijamin ketersediaan suku cadangnya.  


2021 ◽  
Vol 8 (4) ◽  
pp. 119-125
Author(s):  
Wen-Bin Lin ◽  
Kao-Feng Yarn

This paper presents the application of 555 timer circuit. For general PWM control circuit components manner and cost reduction improvements, and apply this system of automatic flow-controlled motor. We use pressure switch to control the rpm of automatic flow-controlled motor. And then, it can enhance the water pressure due to a water tower lack. The system can reach the target of energy –saving and environment friendly by using solar energy. Finally, the consumer can adjust the water flow volume by choosing low speed, middle speed, and high speed of permanent magnet DC motor revolution due to pressure switch control. Keywords: Solar cell, 555 timer circuit, PWM control circuit, Flow-controlled booster motor, Pressure switch.


2021 ◽  
Vol 9 (2) ◽  
pp. 203-215
Author(s):  
Rahmad Samosir ◽  
Kimar Turnip ◽  
Leonard Michael Odi Nathanael

Multi-storey building must be equipped with a reliable building fire extinguishing system. The existing fire extinguishing system design is not equipped with a backup pump and a jockey pump. Based on The DKI Jakarta Governor Regulation No. 92/2014 and the Indonesian National Standard, to solve this problem, a building fire pump system is designed with a combination of the jockey pump, main pump and backup pump that connected in an integrated parallel arrangement. This design allows the backup pump to automatically run due to a pressure drop in the system pipe if the main pump fails or unable to build up pressure. When a fire occurs and a lot of hydrants are used, the backup pump will automatically run to help the main pump with a signal triggered by the pressure switch.


2021 ◽  
Vol 13 (2) ◽  
pp. 182-193
Author(s):  
Imam Setiadi ◽  
Ayudia Mutiara Fani
Keyword(s):  

Kebutuhan masyarakat terhadap air minum yang berkualitas serta akses yang mudah untuk mendapatkanya dan kesadaran mengkonsumsi air minum yang sehat, mendorong semakin banyak inovasi teknologi penyediaan air minum mulai dari yang sederhana bersifat konvensional hingga teknologi modern. Didalam teknologi modern, agar dapat beroperasi dengan baik perlu adanya kontrol yang baik agar unit mesin penyedia air itu dapat bekerja maksimal dan berkesinambungan. Tujuan penelitian ini adalah untuk merancang kontrol  otomatisasi pompa oksidator pada unit penyaringan pendahuluan menggunakan modul PLC agar menjaga efisisiensi suplai bahan kimia oksidasi pada air baku Arsinum. Metode yang digunakan pada aplikasi ini adalah kombinasi 1 buah pressure switch, 2 buah level kontrol pada tangki air baku dan tangki air bersih serta 1 buah modul plc smart relay SRB121FU untuk mengontrol pompa injeksi larutan oksidator bekerja bersamaan dengan pompa air baku ketika melakukan penyaringan. Hasil penelitian menunjukkan bahwa pemasangan modul PLC Smart Relay dapat mengontrol tangki air baku dan tangki air bersih pada proses pretreatment sehingga dapat diperoleh efisiensi pemakaian bahan kimia oksidator pada penolahan air minum ini secara keseluruhan.


2020 ◽  
Vol 67 (11) ◽  
pp. 9833-9840 ◽  
Author(s):  
Mark Pallay ◽  
Ronald N. Miles ◽  
Shahrzad Towfighian

Author(s):  
Agus Sumadi ◽  
Dwi Hadidjaja Rasjid Saputra ◽  
Jamaaluddin Jamaaluddin
Keyword(s):  

Dalam dunia industri plastik mesin kompresor sangat dibutuhkan, penggunaan mesin kompresor membutuhkan udara sebagai penggerak sistem <em>pneumatic</em> dan <em>valve</em>. Pengoperasian mesin kompresor menggunakan <em>pneumatic</em> membutuhkan tekanan udara yang tidak sedikit, karena untuk menjalankan peralatan yang berat dibutuhkan tekanan udara yang tinggi. Jika tekanan udara mesin kompresor berkurang akan berpengaruh pada kualitas produk plastik dan menyebabkan kurang maksimal sistem kerja <em>pneumatic</em> mesin penggerak. Dengan mengimplementasikan sistem kontrol informasi gangguan tekanan udara diharapkan membantu sistem <em>pneumatic</em> dan <em>valve</em>. Bila terjadi gangguan pada peralatan yang terhubung mesin kompresor dengan menggunakan sistem <em>pneumatic</em> kerusakan peralatan mesin kompresor dapat teratasi, sehingga proses produksi berjalan lancar. Penggunaan <em>arduino</em> sebagai kontrol tekanan udara mesin kompresor yang menggunakan <em>pneumatic</em>, sedangkan <em>pressure switch</em> terpasang pada sistem keluaran udara bertekanan dari mesin kompresor. Selanjutnya didistribusikan pada mesin plastik. Jika tekanan udara berkurang, <em>pressure switch</em> akan memberikan sinyal masukan ke <em>arduino</em>. Sinyal modul GSM mengirimkan pesan informasi berupa SMS gangguan tekanan udara terhadap peralatan mesin kompresor kepada nomor teknisi.<em>.</em>


2020 ◽  
Vol 850 ◽  
pp. 297-302
Author(s):  
Ilze Balgale ◽  
Ilze Baltina

In this paper has shown that the three-dimensional hollow weaving technique enables to produce a textile pressure sensor in one continuous process. Based on the multilayer fabric principle, the hollow woven fabrics can be created by connecting adjacent layers of the fabrics according to certain rules. The appropriate fabric structure has been selected and the three-layer weaving technique was used to make the textile pressure switch. The fabric structure is selected to ensure that the top and bottom layers are kept at a distance from each other. The electrically conductive tracks were embedded in the hollow structure of the fabric in bottom and middle layers. Three conditions must be fulfilled in order to create the textile switch: a) the fabric in normal condition keeps the shape required, i.e. the conductive elements are physically separated from each other; b) when the fabric is pressed, conductive elements are in contact, i.e. the switch is now in an electrically on state; c) after the pressure has been removed the fabric returns to its original position, i.e. switch is in an electrically off state. The behavior of the electrically conductive yarn and conductive tracks were tested in various ways. The stainless steel yarn woven in particular way can be used to create woven conductive tracks. Example of application: the pressure sensitive woven rug, the whole area or part of which acts as the pressure sensor or simple switch. The pressure switch in the floor coverings can turn on alarm systems or indicator lamps in the floor or wall coverings for guidance systems in public buildings.


2019 ◽  
Vol 11 (2) ◽  
Author(s):  
Imam Setiadi

Abstrak Dengan meningkatnya kebutuhan masyarakat terhadap air minum yangberkualitas dan kesadaran mengkonsumsi air minum yang sehat, banyak pulateknologi penyediaan air minum yang ditawarkan produsen kepada masyarakat.Mulai dari yang konvensional sampai dengan teknologi modern semuaditawarkan kepada masyarakat. Dari penyaringan biasa sampai denganpenyaringan membrane dengan disain sederhana ataupun dengan disain yangkomplek. Semua menjadi pilihan yang harus disesuaikan dengan kebutuhanmasyarakat. Penyediaan teknologi penyediaan air minum agar dapat beroperasidengan baik harus ada kontrol yang baik sehingga unit mesin penyedia air itudapat bekerja maksimal dan berkesinambungan. Kontrol pengaman aliran airumpan adalah salah satu contoh sistem kontrol pengaman yang dapat diterapkansecara mudah pada unit-unit tersebut dengan jaminan ketersediaan sukucadangnya yang bisa dibeli di kota-kota kecil. Sistem kontrol ini menggunakanpressure switch yang dikombinasikan dengan selenoid valve. Kombinasi inidengan melakukan pengaturan tekanan air akan mengamankan unit pengolahanair minum jadi unit ini tidak akan bekerja apabila tidak ada pasokan air.Kata kunci : air minum, kontrol, pressure swich, solenoid valve


Sign in / Sign up

Export Citation Format

Share Document