scholarly journals 8 EFFECT OF SUCKLING RESTRICTION AND eCG TREATMENT ON PREGNANCY RATES IN POSTPARTUM BOS INDICUS CROSSBRED COWS TREATED WITH PROGESTERONE VAGINAL DEVICES AND ESTRADIOL BENZOATE

2005 ◽  
Vol 17 (2) ◽  
pp. 154
Author(s):  
E. Balla ◽  
L. Cutaia ◽  
C. Rizzi ◽  
L. Peres ◽  
G.A. Bo

Previous studies have shown that the use of eCG given at the time of removal of a progesterone (P4) releasing device improved pregnancy rates to fixed-time AI (FTAI) in postpartum Bos indicus cows (Bo GA et al. 2004 Reprod. Fertil. Dev. 16, 127). Suckling restriction with the placement of nose tags in calves has also been shown to induce cyclicity and increase pregnancy rates in postpartum Bos indicus cows (Stahringer RC 2003 Taurus 18, 21–23). An experiment was designed to compare the effect of eCG treatment and restricted suckling on pregnancy rates in postpartum cows in fair to poor body condition score (BCS). A secondary objective was to evaluate the effect of restricted suckling on weaning weights. Lactating primiparous crossbred Bos indicus cows (n = 399), 60 to 90 days postpartum with a BCS 2.0 (1 to 5 scale), were randomly allocated to 1 of 4 treatment groups, in a 2 × 2 factorial design. On Day 0, all cows received a P4 intravaginal device (DIB, Syntex, Argentina) and 2 mg estradiol benzoate (EB) i.m. (Syntex). On Day 8, DIB devices were removed and all cows received 150 μg D(+)cloprostenol i.m. (Ciclase, Syntex) and were randomly divided to receive 400 IU eCG (Novormon, Syntex) or no treatment at the same time. On Day 9, all cows received 1 mg EB i.m. and were FTAI 52 to 56 h after DIB removal. Nose tags were placed in half of the calves from Day 0 to the time of FTAI, whereas the other half of the calves remained untreated. All cows were examined by ultrasonography 30 d after FTAI to determine pregnancy status. Pregnancy data were analyzed by logistic regression, and birth and weaning weights were analyzed by Student's t-test. Ovarian activity was estimated by rectal palpation on Day 0: there were 57/399 (14.3%) cows with a CL, 203/399 (50.8%) cows with palpable medium size follicles, and 139/399 (34.8%) cows with ovaries containing no detectable structures. There was no effect of ovarian status at the time of treatment (P = 0.52) or semen (P = 0.89) on pregnancy rates. Suckling restriction increased (P = 0.03) pregnancy rates (91/195, 46.6% and 81/204, 39.7% for cows not suckled or suckled during the treatment, respectively). However, there was no effect of eCG or eCG by weaning interaction (P = 0.82) on pregnancy rates (82/192, 42.7% and 90/207, 43.4% for cows treated or not treated with eCG, respectively). Although mean (±SEM) birth weights were not different (29.4 ± 0.4 vs. 29.1 ± 0.4; P = 0.6), weaning weights were significantly affected (P = 0.001) by the suckling restriction (190.1 ± 1.9 vs. 200.4 ± 2.1 for calves treated or not treated with the nose tags, respectively). Although restricting suckling, by placement of a nose tag from Day 0 to FTAI, may increase pregnancy rates in primiparous Bos indicus cows in fair to poor BCS, the adverse effect of this treatment on weaning weights of the calves has to be considered. Furthermore, eCG did not increase pregnancy rates in the present study, as it has been previously reported. Research was supported by Syntex S.A., Estancia El Mangrullo S.A., and Agencia Cordoba Ciencia S.E.

2005 ◽  
Vol 17 (2) ◽  
pp. 157
Author(s):  
L. Cutaia ◽  
E. Balla ◽  
C. Rizzi ◽  
L. Peres ◽  
G.A. Bo

Although treatments with progesterone (P4)-releasing devices and estradiol benzoate (EB) have been extensively used in fixed-time AI (FTAI) programs in beef cattle, pregnancy rates in postpartum Bos indicus cows kept on pasture often have been lower than expected because of poor body condition score (BCS) and a high incidence of anestrus. Temporary weaning and eCG treatment have been shown to increase pregnancy rates in suckled beef cows. Therefore, this experiment was designed to compare the effect of eCG treatment and temporary weaning on pregnancy rates in postpartum cows in fair to poor BCS. Lactating multiparous crossbred Bos indicus cows (n = 393), 60 to 90 d postpartum with a BCS 2.0 (1 to 5 scale) were randomly allocated to 1 of 4 treatment groups, in a 2 × 2 factorial design. At the beginning of the experiment (Day 0), all cows received a P4 intravaginal device (DIB, Syntex, Argentina) and 2 mg EB i.m. (Syntex). On Day 8, DIB devices were removed and all cows received 150 μg D (+) cloprostenol i.m. (Ciclase, Syntex) and were randomly divided to receive 400 IU eCG (Novormon 5000, Syntex) or no treatment at the same time. Furthermore, half of the cows in each treatment group have their calves weaned temporarily, from the time of DIB removal until the end of the FTAI, whereas the other half remained with their calves all the time. Finally, all cows received 1 mg EB i.m. on Day 9 and were FTAI 52 to 56 h after DIB removal. Cows were examined by ultrasonography 42 d after FTAI to determine pregnancy status. Data were analyzed by logistic regression and the effects of treatment and semen used were considered in the model. Ovarian activity was estimated by rectal palpation on Day 0: there were 72/393 (18.2%) cows with a CL, 140/393 (35.6%) cows with palpable medium size follicles, and 181/393 (46.1%) cows with ovaries containing no detectable structures. There was no effect of ovarian status at the time of treatment (P = 0.91) or semen (P = 0.91) on pregnancy rates. Treatment with eCG tended (P = 0.08) to increase pregnancy rates (94/192, 48.9% and 79/201, 39.3% for cows treated or not treated with eCG, respectively). However, there was no effect of weaning or eCG by weaning interaction (P = 0.98) on pregnancy rates (86/191, 45.1% and 87/202, 43.1% for cows that have their calves weaned or not weaned for 56 h, respectively). Results confirm those of previous studies that demonstrated that the use of eCG in a P4/EB/FTAI program improved pregnancy rates in postpartum Bos indicus crossbred cows that were in fair-to-poor BCS. However, no improvement in pregnancy rates was observed after temporary weaning in the present study. Research was supported by Syntex S.A., Estancia El Mangrullo S.A., and Agencia Cordoba Ciencia S.E.


2010 ◽  
Vol 22 (1) ◽  
pp. 177 ◽  
Author(s):  
M. Ramos ◽  
L. Cutaia ◽  
P. Chesta ◽  
G. A. Bó

Two experiments were designed to evaluate the effect of the timing of fixed-time AI (FTAI) in relation to the removal of an intravaginal progesterone-releasing device (1 g of progesterone, DIB, Syntex SA, Buenos Aires, Argentina) on pregnancy rates in Bos indicus × Bos taurus cross-bred heifers. In experiment 1, 285 Bonsmara × zebu cross-bred heifers, between 18 and 24 months of age and with a body condition score (BCS) between 3.0 and 3.5 (1-5 scale) were used. On the day of initiation of treatment (Day 0), the heifers’ ovaries were palpated (92% of them had a CL) and they received a new DIB plus 2 mg of estradiol benzoate (EB; Syntex SA) and 250 μg of cloprostenol (Ciclase DL, Syntex SA). On Day 8, DIB devices were removed and all heifers received 250 μg of Ciclase plus 0.5 mg of estradiol cypionate (ECP; Cipiosyn, Syntex SA). At that time the heifers were randomly divided to receive FTAI between 48 to 49 h, 53 to 54 h, or 58 to 59 h after DIB removal. The heifers underwent FTAI with semen from 4 bulls by 2 inseminators. In experiment 2, 260 heifers from the same group as those used in experiment 1 (87% with a CL) were treated exactly as those in experiment 1, except that previously used DIB was inserted on Day 0. Pregnancy diagnosis was performed 30 days post-fixed-time AI by ultrasonography. The data were analyzed by logistic regression, taking into account the effect of time of FTAI, semen, and inseminator on pregnancy rates. In experiment 1, pregnancy rates were lower (P = 0.04) in the heifers undergoing FTAI between 48 and 49 h after DIB removal (46/95, 48.4%) than those undergoing FTAI 53 to 54 h (61/99, 61.6%) or 58 to 60 h (57/91, 62.6%) after DIB removal. However, no differences in pregnancy rates were found (P = 0.72) in experiment 2 between the 3 treatment groups, with 39/91 (42.9%) for the 48 to 49 h group, 45/89 (50.6%) for the 53 to 54 h group, and 35/89 (43.8%) for the 58 to 59 h group. There was no effect of the semen or inseminator (P > 0.2) in either experiment. We conclude that when Bos indicus × Bos taurus beef heifers are synchronized with new DIB devices and ECP, higher pregnancy rates are obtained in heifers undergoing FTAI late (between 53 to 60 h after DIB removal) than in those undergoing FTAI early (48 to 49 h after DIB removal). However, time of insemination does not apparently affect pregnancy rates when Bos indicus × Bos taurus beef heifers are synchronized with previously used DIB devices and ECP.


2004 ◽  
Vol 16 (2) ◽  
pp. 127 ◽  
Author(s):  
G.A Bo ◽  
L. Cutaia ◽  
P. Chesta ◽  
D. Moreno

Treatments with progesterone (P4) releasing devices and estradiol benzoate (EB) have been extensively used in fixed-time AI (FTAI) programs in beef cattle. However, pregnancy rates in postpartum cows kept on pasture often have been lower than expected because of poor body condition score (BCS) and a high incidence of anestrous. A recent study (Cutaia L et al., 2003 Theriogenology 59, 216) suggested that the addition of eCG to a P4/EB FTAI program may improve pregnancy rates in cows with fair to poor BCS, but results were not conclusive. Therefore, this experiment was designed to further investigate the effect of eCG treatment on pregnancy rates in postpartum beef cows in those conditions. The experiment was performed at 2 locations with lactating Angus cows (n=93), 60 to 90d postpartum with a BCS 1.9 (1 to 5 scale; Location 1), and crossbred Zebu cows (n=290), 60 to 90d postpartum with a BCS 2.0 (Location 2). In each Location, cows were randomly allocated to 1 of the following treatment groups: Control, eCG Day6, or eCG Day8. All cows received a P4 intravaginal device (DIB, Syntex, Argentina) and 2mg EB i.m. (Syntex) on Day0, 500mg cloprostenol (Estroplan, Syntex) at the time of DIB removal (Day8), 1mg EB i.m. on Day9 and FTAI 52 to 56h after DIB removal. Cows in the Control group received no further treatment, whereas cows in the eCG-treated groups received 400 IU eCG (Novormon 5000, Syntex) on Day6 or Day8. Cows were examined on Day0 by rectal palpation (Location 1) or by ultrasonography (US; Location 2) and were classified as those with a CL or without a CL, with either large (>8mm) or small (<8mm)small follicles. Pregnancy was determined by US 45d after FTAI. Data were analyzed by logistic regression and the effects of location, treatment, ovarian status, AI technician and semen were considered in the model. There was no effect of location (P=0.3), AI technician (P=0.2) or semen (P=0.8) on pregnancy rates. However, there was an effect of treatment (P=0.02), attributed to higher pregnancy rates in the eCG Groups than in the Control Group (Table). Furthermore, cows with a CL or without a CL but with large follicles on Day 0 had higher pregnancy rates than those with small follicles (P=0.04). It was concluded that the use of eCG in a P4/EB FTAI program improved pregnancy rates in postpartum beef cows that were in fair topoor BCS.


2010 ◽  
Vol 22 (1) ◽  
pp. 168 ◽  
Author(s):  
L. Cutaia ◽  
M. Ramos ◽  
P. Chesta ◽  
G. A. Bó

An experiment was designed to test the following hypotheses: (1) the administration of 400IU of eCG (Novormón, Syntex SA, Buenos Aires, Argentina) 14 days after fixed-time artificial insemination (FTAI) increases pregnancy rates in cross-breed Zebu × Bonsmara suckled cows synchronized with progesterone releasing devices (DIB 0.5, 0.5 g of progesterone, Syntex SA); and (2) pregnancy rates in cows treated with estradiol or GnRH, combined with a DIB device, are not different. Primiparous suckled cows (n = 260), between 60 and 120 days postpartum (DPP) and with a body condition score between 2.0 and 2.5 (1 to 5 scale) were used. At the beginning of the experiment (Day 0), all cows were examined by rectal palpation (only 11% had a CL), received a DIB device, and were randomly allocated to 1 of 3 treatment groups. Cows in the E2 group received 2 mg of estradiol benzoate (EB) intramuscularly (i.m.) at DIB insertion and those in the two GnRH groups received 100 μg of gonadorelin (GDR Gonasyn, Syntex SA) at the same time. On Day 7, DIB devices were removed and all cows received 500 μg of cloprostenol (Ciclase DL, Syntex SA) plus 400 IU of eCG (i.m.). Cows in the E2 group received 0.5 mg of estradiol cypionate (ECP, Cipiosyn, Syntex SA) and underwent FTAI administered by one technician, using semen from 1 of 2 bulls between 52 and 56 h later. Cows in the GnRH groups received a dose of 100 μg of gonadorelin (full GnRH group) or 50 μg of gonadorelin (1/2 GnRH group) at the time of the FTAI (52 to 56 h after DIB removal). Fourteen days after FTAI cows in the 3 groups were further subdivided (3 × 2 factorial) to receive or not 400 IU of eCG i.m. Pregnancy was determined 30 days after FTAI using real-time ultrasonography. Data were analyzed by logistic regression, taking into account the effect of the synchronization treatment, eCG or noteCG, 14 days after FTAI and sire used. No differences in pregnancy rates were found (P = 0.16) among treatment groups (E2: 39/87, 43.7%, full GnRH: 38/92, 41.3%, and 1/2 GnRH: 25/81, 30.9%). However, there was a significant (P = 0.02) effect of eCG treatment 14 days after FTAI (eCG: 60/127, 47.2% v. no eCG: 41/133, 30.8%). Furthermore, bull A (77/155, 47.1%) resulted in higher pregnancy rate (P = 0.009) than bull B (28/107, 26.2%), but there were no significant interactions between bull and synchronization treatment or eCG administration 14 days after FTAI (P > 0.1). We conclude that the application of 400 IU of eCG 14 days after FTAI increases pregnancy rates in suckled Bos taurus × Bos indicus primiparous cows with fair to poor body condition score synchronized with progesterone releasing devices. Furthermore, the use of estradiol ester or GnRH at DIB insertion and removal did not affect pregnancy rates.


2007 ◽  
Vol 19 (1) ◽  
pp. 220
Author(s):  
G. A. Bo ◽  
L. C. Peres ◽  
D. Pincinato ◽  
M. de la Rey ◽  
R. Tribulo

An experiment was designed to evaluate the effect of the interval between thawing to deposition of the embryo into the uterine horn on pregnancy rates of in vivo-produced frozen–thawed embryos in 1.5 M ethylene glycol (direct transfer). Data were collected from 1122 embryo transfers performed in the same farm (Estancia El Mangrullo, Lavalle, Santiago del Estero, Argentina) during the spring and summer of 2004/05 and 2005/06 (6 replicates, ambient temperature between 20 and 40�C). Recipients used in all replicates were non-lactating, cycling, multiparous Bos taurus � Bos indicus crossbred cows with body condition score between 3 and 4 (1 to 5 scale) that were synchronized using fixed-time embryo transfer protocols. Briefly, the synchronization treatments consisted of the insertion of a Crestar ear implant (Intervet, Sao Paulo, Brazil) or a progesterone-releasing device (DIB; Syntex SA, Buenos Aires, Argentina), plus 2 mg of estradiol benzoate (EB; Syntex) intramuscularly (IM) on Day 0, and 400 IU of eCG (Folligon 5000; Intervet, or Novormon 5000; Syntex) IM plus 150 �g d-cloprostenol IM (Preloban; Intervet, or Ciclase; Syntex) on Day 5. Progestin devices were removed on Day 8 and all cows received 1 mg of EB IM on Day 9. All cows were examined by ultrasonography on Day 16 and those with a luteal area >76 mm2 (by calculating the area of the CL minus the area of the cavity) received, on Day 17, frozen–thawed embryos by nonsurgical transfer. All embryos were Grade 1, and all were frozen in 1.5 M ethylene glycol at the Embryo Plus Laboratory (Brits, South Africa). After being stored in liquid nitrogen, the embryos were plunged directly (no air thawing) in a 30�C water bath for 30 s, and then transferred to the recipient cows by either one of two technicians. Based on the interval between thawing and transfer, the transfers were classified as being in one of 3 groups: Group 1: <3 min; Group 2: 3 to 6 min; and Group 3: 6 to 16 min. The main reason for delayed transfers beyond 6 min was the replacement of one recipient for another because of difficulty in threading the cervix (1% of the total transfers) or a recipient falling down into the chute or with very bad disposition and behavior. Pregnancy was determined by ultrasonography 28 to 35 days after fixed-time embryo transfer, and data were analyzed by logistic regression. There were no effects of replicate, technician, CL area, recipient body condition score, embryo stage, and time from thawing to transfer on pregnancy rates. Pregnancy rates in the 3 thawing to transfer intervals were: Group 1: 215/385, 55.8%; Group 2: 372/655, 56.8%; Group 3: 42/82, 51.2%; P > 0.6. These results may be interpreted to suggest that there is no significant effect of time from thawing to transfer (up to 16 min) in direct transfer embryos using Bos taurus � Bos indicus recipients transferred at a fixed time.


2005 ◽  
Vol 17 (2) ◽  
pp. 234 ◽  
Author(s):  
R. Tribulo ◽  
E. Balla ◽  
L. Cutaia ◽  
G.A. Bo ◽  
P.S. Baruselli ◽  
...  

Although several studies have investigated the relationship between circulating progesterone and pregnancy rates in cattle, the beneficial effect of treatments that increase progesterone concentrations, by insertion of a progesterone (P4) releasing device or induction of an accessory CL with hCG, GnRH, or LH treatment, has resulted in inconsistent effects on pregnancy rates in embryo recipients. An experiment was designed to evaluate the effect of hCG or GnRH treatment, given at the time of embryo transfer without estrus detection, on pregnancy rates in recipients treated with intrauterine P4-releasing devices, estradiol benzoate (EB), and eCG. The experiment was performed in two replicates; non-lactating Bos taurus × Bos indicus crossbred beef cows with a body condition score between 2.5 to 3.5 (1-to-5 scale) were used (replicate 1, n = 180; replicate 2, n = 140). All cows received 1 g of P4 via a P4-releasing device (DIB, Syntex, Argentina) and 2 mg EB i.m. (Syntex) on Day 0, and 400 IU of eCG i.m. (Novormon 5000, Syntex) plus 150 μg d(+)cloprostenol i.m. (Ciclase, Syntex) on Day 5. DIBs were removed on Day 8 and all cows received 1 mg EB i.m. on Day 9. Recipients were not observed for signs of estrus, and those >1 CL, or a single CL with an area >256 mm2, received 195 Grade 1 and 46 Grade 2 frozen/thawed “direct transfer” embryos on Day 17. At the time of embryo transfer, recipients were randomly allocated to 1 of 3 treatment groups to receive 1500 IU hCG (Ovusyn, Syntex), 50 μg Lecirelina (GnRH, Gonasyn, Syntex), or no treatment (control) at that time. Ovarian ultrasonography was performed on Day 0 to determine ovarian status (only cows with a CL or a follicle >10 mm and uterine tone were used), on Day 17 to measure CL area, and 40 days after embryo transfer to determine pregnancy status. Data were analyzed by logistic regression and the effects of replication, technician, treatment, and embryo quality were considered in the model. From the 320 recipients treated with a DIB plus EB and eCG, 241 (75.3%) were selected to receive an embryo. Nine (3.7%) and 1 (0.4%) of the selected recipients had 2 and 3 CL, respectively. Pregnancy rates did not differ between replicates (replicate 1: 80/140, 57.1%; and replicate 2: 57/101, 56.4%; P = 0.84), technicians (technician 1: 65/118, 55.1%; and technician 2: 72/123, 58.5%; P = 0.64), or treatments (hCG: 43/80, 53.8%; GnRH: 45/83, 54.2%; and control: 49/78, 62.8% P = 0.99). However, pregnancy rates were higher (P = 0.001) in recipients receiving Grade 1 embryos (121/195, 62.1%) than in those receiving Grade 2 embryos (16/46, 34.8%). GnRH or hCG treatment at the time of embryo transfer did not increase pregnancy rates in recipients synchronized with P4 releasing devices, EB, and eCG. Research was supported by Syntex S.A., Estancia El Mangrullo S.A., and Agencia Cordoba Ciencia S.E.


2020 ◽  
Vol 32 (2) ◽  
pp. 213
Author(s):  
G. A. Bo ◽  
A. Cedeño ◽  
R. Maingón ◽  
J. P. Cedeño ◽  
H. Gamboa ◽  
...  

An experiment was designed to evaluate the effect of the length of insertion of a progesterone (P4)-releasing device and the length of pro-oestrus on follicular and luteal characteristics and pregnancy rates to AI (P/AI) in Bos indicus heifers treated with oestradiol/P4-based treatments. Bos indicus beef heifers (n=374), 22-26 months of age, with a corpus luteum (CL) or at least one follicle ≥8mm in diameter and with a body condition score between 2.5 and 3.5 (1-to-5 scale) were synchronised using three treatments for fixed-time AI (FTAI). On Day 0, all heifers received 2mg of oestradiol benzoate (Sincrodiol, Ourofino) and an intravaginal device with 1g of P4 (Sincrogest, Ourofino). The P4 device was removed on Day 6 in heifers in the J-Synch 6 group (n=120) and on Day 7 in heifers in the J-Synch 7 group (n=105) and conventional group (n=165). All heifers received 500μg of cloprostenol (Sincrocio, Ourofino) and 300IU of equine chorionic gonadotrophin (SincroeCG 6000UI, Ourofino) at the time of P4 device removal. Furthermore, heifers in the conventional treatment group received 0.5mg of oestradiol cypionate (SincroCP, Ourofino) at the same time. In addition, all heifers were tail-painted for oestrus detection (CeloTest, Biotay). Heifers that had lost ≥50% of the tail paint by 70-74h (J-Synch groups) or 48-52h (conventional group) after device removal were FTAI at that time. Heifers not showing oestrus by 70-74h (J-Synch groups) or 48-52h (conventional group) received 10μg of gonadotrophin-releasing hormone (Sincroforte, Ourofino) at the same time and were FTAI 8h later. All heifers were also examined using ultrasonography (Mindray DP50 Vet) every 12h from the time of device removal to determine the time of ovulation, 6 days after ovulation to determine the diameter of the CL, and 28 days after FTAI for P/AI determination. Data were analysed using the MLGM procedure (InfoStat) for normal data families (follicular dynamics) and binary data family (P/AI). The results are shown in Table 1. The diameter of the dominant preovulatory follicle and the CL did not differ among groups (P>0.12). However, the interval from device removal to ovulation was longer in heifers in the J-Synch groups than in heifers in the conventional group (P<0.05). Furthermore, P/AI was not different among groups. In conclusion, although the J-Synch protocols delayed the interval from P4 device removal to ovulation, the three protocols evaluated in the present study were equally effective in Bos indicus heifers. Table 1.Mean (±s.e.m.) diameter of the preovulatory follicle (P/Foll) and corpus luteum (CL), interval from progesterone (P4) device removal to ovulation, and pregnancy rates to AI (P/AI) in Bos indicus heifers Treatment P/Foll, mm Interval to ovulation, h CL diameter, mm P/AI,% (n) J-Synch 6 10.5±0.7 101.4±2.3a 18.6±1.0 52.0 (62/120) J-Synch 7 10.6±0.7 96.0±2.2a 16.5±0.9 39.0 (41/105) Conventional 9.4±0.7 73.0±1.9b 16.8±0.9 45.0 (74/165) a,bDifferent superscripts denote differences between groups in the interval from P4 device removal to ovulation.


2007 ◽  
Vol 19 (1) ◽  
pp. 224
Author(s):  
L. C. Peres ◽  
D. Pincinato ◽  
L. Cutaia ◽  
R. Tribulo ◽  
G. A. Bo

An experiment was designed to evaluate alternative treatment protocols for fixed-time embryo transfer (FTET) in recipients in order to reduce cattle handling. Non-lactating, cycling Bos taurus � Bos indicus beef cows (n = 918), with a body condition score (BCS) of 2.5 to 3.5 out of 5, received a progesterone-releasing device (DIB; Syntex, Buenos Aires, Argentina) and 2 mg estradiol benzoate (EB; Syntex) IM on random days of the cycle (Day 0); DIB were removed on Day 8. Cows were placed randomly into 6 treatment groups in a 3 � 2 factorial design. The factors evaluated were time of administration of PGF and eCG [control treatment: PGF Day 5 and eCG Day 5 (Bo et al. 2002 Theriogenology 57, 53–72); PGF Days 0 and 8 and eCG Day 5; PGF Days 0 and 8 and eCG Day 8] and the time of administration of the second injection of EB (at DIB removal or 24 h later). Therefore, cows in the control treatment received 150 �g of d-Cloprostenol (PGF, Ciclase; Syntex) and 400 IU eCG (Novormon; Syntex) on Day 5, whereas cows in the other 2 treatments received 75 �g of PGF on Days 0 and 8 and 400 IU eCG on either Day 5 or Day 8. Each treatment group was further subdivided to receive 1 mg EB IM on either Day 8 (EB Day 8) or Day 9 (EB Day 9). All recipients, whether observed in estrus or not and with more than one CL with luteal area (total CL area minus cavity area) >76 mm2 on the day before embryo transfer, received frozen-thawed embryos (IETS Grade 1) on Day 16 (EB Day 8) or Day 17 (EB Day 9) by direct transfer. Pregnancy was determined by ultrasonography 30 days after FTET. Continuous data were analyzed by ANOVA and pregnancy rates were analyzed by logistic regression. No effects of body condition score or technician were detected (P > 0.1). Although there were no differences in conception rates between recipients treated with EB on Day 8 or Day 9 (168/321, 52.3% vs. 203/350, 58.0%, respectively; P > 0.1), treatment with EB on Day 8 resulted in fewer recipients selected/treated (321/460, 69.7% vs. 350/458, 76.4%; P < 0.05) and pregnant/treated (168/460, 36.5% vs. 203/458, 44.3%; P < 0.05) than 24 h later (EB Day 9), respectively. The mean interval from DIB removal to estrus was shorter (P < 0.05) for recipients in the EB Day 8 (28.1 � 7.2 h) than in the EB Day 9 (43.5 � 9.4 h) group, and the mean (� SEM) CL area was also less in the EB Day 8 group than in the EB Day 9 group (261.7 � 96.7 vs. 293.1 � 114. mm2; P < 0.05). The number of recipients selected/treated was higher in the group receiving PGF on Days 0 and 8 and eCG on Day 8 (243/305, 79.6%) than in the group receiving PGF on Days 0 and 8 and eCG on Day 5 (208/301, 69.1%) or the control group (220/312, 70.5%). Although the luteal area was greater (P < 0.05) in the PGF on Days 0 and 8 and eCG on Day 5 group (304.4 � 127.1 mm2) than in the groups receiving PGF and eCG on Day 5 (274.6 � 98.6 mm2) or PGF on Days 0 and 8 and eCG Day 8 (258.4 � 90.2 mm2), pregnancy rates did not differ between PGF and eCG treatment groups (P > 0.05). It was concluded that it may be possible to reduce animal handling by treating recipients with a half dose of PGF at the time of DIB insertion and removal, when eCG is also administered, without compromising pregnancy rates.


2013 ◽  
Vol 25 (1) ◽  
pp. 159
Author(s):  
J. P. Detomini ◽  
R. R. Tirloni ◽  
C. V. Araujo ◽  
L. R. Martins

The aim of this study was to establish a comparison between heterospermic and monospermic semen on the pregnancy rate of fixed-time AI Bos indicus cows. The experiment was conducted in the state of Mato Grosso, Brazil, during December 2010 and February 2011. Multiparous (n = 173) and primiparous (n = 204) Nelore cows, 45 ± 15 days postpartum, were evaluated on body condition score (BCS; score 1 to 9), and those that presented BCS between 5 and 8 were selected. Two protocols of estrous cycle synchronization were performed (PeCG and Pshang). Synchronization of the estrous cycle was achieved with the aid of the following protocol: on Day 0, all animals were treated with a progesterone vaginal implant with 1.9 g of progesterone combined with an IM injection of 2 mg of estradiol benzoate. On Day 7, an IM injection of 12.5 mg of dinoprost was administered. On Day 9, implants were withdrawn and the animals received an IM injection of 0.5 mg of estradiol cypionate. On Day 9, part of the animals (n = 222) received an IM injection of 300 IU mg of eCG (PeCG) and the other part (n = 155) had their calves removed for 48 hours (Pshang). All animals were inseminated 46 to 52 h after the end of the protocol. Cows were allocated randomly in 4 groups according to the donor male sample in the semen straw and groups were designated as MA (monospermic straw from bull A; n = 110), MB (monospermic straw from bull B; n = 102), MC (monospermic straw from bull C; n = 108), and HT (heterospermic sample from bulls A, B, and C; n = 57). Commercially available semen straws from Aberdeen Angus donors were used (ABS Pecplan, Brazil). Pregnancy diagnosis was performed 35 days after AI using real-time ultrasonography. Results are summarized in Table 1. There was no statistical difference between MA, MB, MC, and HT in any group according to the chi-square test (P > 0.05). However, there was a remarkable difference in pregnancy rates among the 3 bulls tested considering both protocols, probably due to the variation in the ovulation moment. Table 1.Pregnancy rates of Nelore cows submitted to FTAI protocol inseminated with monospermic (bull A, B, or C) or heterospermic (HT) semen


2006 ◽  
Vol 18 (2) ◽  
pp. 114
Author(s):  
L. Cutaia ◽  
M. Aviles ◽  
F. Feresin ◽  
A. Franzoni ◽  
L. Peres ◽  
...  

Three experiments were conducted to compare pregnancy rates in cows and heifers treated with intravaginal progesterone (P4)-releasing devices impregnated with either 0.5 or 1.0 g of P4 and inseminated at a fixed time (FTAI). In Experiment 1, 102 postpartum beef cows (Hereford and Angus crossbred with Tuli, 60 to 90 d postpartum) with a body condition score (BCS) of 2.5 to 3.0 (1 to 5 scale) were used. On Day 0, all cows received 2 mg of estradiol benzoate (EB; Syntex, Argentina) i.m. and were randomly assigned to receive an intravaginal progesterone-releasing device with 0.5 g of P4 (DIB 0.5 g; Syntex) or 1.0 g of P4 (DIB 1.0 g; Syntex). On Day 7, DIB devices were removed and all cows received 150 µg D(+)cloprostenol (Ciclase; Syntex) i.m. On Day 8, all cows received 1 mg EB and were FTAI 52 to 56 h after DIB removal. In Experiment 2, 93 Holstein cows that were 90 to 110 days in milk (DIM), producing on average 5000 kg of milk per lactation and with a BCS of 2.5 to 3.0 received the same treatments as those in Experiment 1. In Experiment 3, 100 Holstein heifers, 20 to 22 months old, with a BCS of 2.5 to 3.0, also received the same treatments as those in Experiment 1. Pregnancy rates in all experiments were determined by ultrasonography 35 days after FTAI and compared by chi-square test. No differences in pregnancy rates were detected between lactating beef cows, dairy cows, or dairy heifers treated with DIB devices impregnated with 0.5 or 1.0 g of P4 (Table 1). It was concluded that vaginal P4 releasing devices impregnated with 0.5 g or 1.0 g of P4 results in comparable pregnancy rates in FTAI protocols in beef and dairy cattle. Table 1. Pregnancy rates in postpartum beef cows, Holstein cows, and Holstein heifers treated with DIB devices impregnated with 0.5 or 1.0 g of P4 and subjected to FTAI


Sign in / Sign up

Export Citation Format

Share Document