20 PREGNANCY RATES IN SUCKLED BEEF COWS SYNCHRONIZED WITH PROGESTERONE INTRAVAGINAL DEVICES AND RECEIVING eCG FOURTEEN DAYS AFTER BREEDING

2010 ◽  
Vol 22 (1) ◽  
pp. 168 ◽  
Author(s):  
L. Cutaia ◽  
M. Ramos ◽  
P. Chesta ◽  
G. A. Bó

An experiment was designed to test the following hypotheses: (1) the administration of 400IU of eCG (Novormón, Syntex SA, Buenos Aires, Argentina) 14 days after fixed-time artificial insemination (FTAI) increases pregnancy rates in cross-breed Zebu × Bonsmara suckled cows synchronized with progesterone releasing devices (DIB 0.5, 0.5 g of progesterone, Syntex SA); and (2) pregnancy rates in cows treated with estradiol or GnRH, combined with a DIB device, are not different. Primiparous suckled cows (n = 260), between 60 and 120 days postpartum (DPP) and with a body condition score between 2.0 and 2.5 (1 to 5 scale) were used. At the beginning of the experiment (Day 0), all cows were examined by rectal palpation (only 11% had a CL), received a DIB device, and were randomly allocated to 1 of 3 treatment groups. Cows in the E2 group received 2 mg of estradiol benzoate (EB) intramuscularly (i.m.) at DIB insertion and those in the two GnRH groups received 100 μg of gonadorelin (GDR Gonasyn, Syntex SA) at the same time. On Day 7, DIB devices were removed and all cows received 500 μg of cloprostenol (Ciclase DL, Syntex SA) plus 400 IU of eCG (i.m.). Cows in the E2 group received 0.5 mg of estradiol cypionate (ECP, Cipiosyn, Syntex SA) and underwent FTAI administered by one technician, using semen from 1 of 2 bulls between 52 and 56 h later. Cows in the GnRH groups received a dose of 100 μg of gonadorelin (full GnRH group) or 50 μg of gonadorelin (1/2 GnRH group) at the time of the FTAI (52 to 56 h after DIB removal). Fourteen days after FTAI cows in the 3 groups were further subdivided (3 × 2 factorial) to receive or not 400 IU of eCG i.m. Pregnancy was determined 30 days after FTAI using real-time ultrasonography. Data were analyzed by logistic regression, taking into account the effect of the synchronization treatment, eCG or noteCG, 14 days after FTAI and sire used. No differences in pregnancy rates were found (P = 0.16) among treatment groups (E2: 39/87, 43.7%, full GnRH: 38/92, 41.3%, and 1/2 GnRH: 25/81, 30.9%). However, there was a significant (P = 0.02) effect of eCG treatment 14 days after FTAI (eCG: 60/127, 47.2% v. no eCG: 41/133, 30.8%). Furthermore, bull A (77/155, 47.1%) resulted in higher pregnancy rate (P = 0.009) than bull B (28/107, 26.2%), but there were no significant interactions between bull and synchronization treatment or eCG administration 14 days after FTAI (P > 0.1). We conclude that the application of 400 IU of eCG 14 days after FTAI increases pregnancy rates in suckled Bos taurus × Bos indicus primiparous cows with fair to poor body condition score synchronized with progesterone releasing devices. Furthermore, the use of estradiol ester or GnRH at DIB insertion and removal did not affect pregnancy rates.


2010 ◽  
Vol 22 (1) ◽  
pp. 177 ◽  
Author(s):  
M. Ramos ◽  
L. Cutaia ◽  
P. Chesta ◽  
G. A. Bó

Two experiments were designed to evaluate the effect of the timing of fixed-time AI (FTAI) in relation to the removal of an intravaginal progesterone-releasing device (1 g of progesterone, DIB, Syntex SA, Buenos Aires, Argentina) on pregnancy rates in Bos indicus × Bos taurus cross-bred heifers. In experiment 1, 285 Bonsmara × zebu cross-bred heifers, between 18 and 24 months of age and with a body condition score (BCS) between 3.0 and 3.5 (1-5 scale) were used. On the day of initiation of treatment (Day 0), the heifers’ ovaries were palpated (92% of them had a CL) and they received a new DIB plus 2 mg of estradiol benzoate (EB; Syntex SA) and 250 μg of cloprostenol (Ciclase DL, Syntex SA). On Day 8, DIB devices were removed and all heifers received 250 μg of Ciclase plus 0.5 mg of estradiol cypionate (ECP; Cipiosyn, Syntex SA). At that time the heifers were randomly divided to receive FTAI between 48 to 49 h, 53 to 54 h, or 58 to 59 h after DIB removal. The heifers underwent FTAI with semen from 4 bulls by 2 inseminators. In experiment 2, 260 heifers from the same group as those used in experiment 1 (87% with a CL) were treated exactly as those in experiment 1, except that previously used DIB was inserted on Day 0. Pregnancy diagnosis was performed 30 days post-fixed-time AI by ultrasonography. The data were analyzed by logistic regression, taking into account the effect of time of FTAI, semen, and inseminator on pregnancy rates. In experiment 1, pregnancy rates were lower (P = 0.04) in the heifers undergoing FTAI between 48 and 49 h after DIB removal (46/95, 48.4%) than those undergoing FTAI 53 to 54 h (61/99, 61.6%) or 58 to 60 h (57/91, 62.6%) after DIB removal. However, no differences in pregnancy rates were found (P = 0.72) in experiment 2 between the 3 treatment groups, with 39/91 (42.9%) for the 48 to 49 h group, 45/89 (50.6%) for the 53 to 54 h group, and 35/89 (43.8%) for the 58 to 59 h group. There was no effect of the semen or inseminator (P > 0.2) in either experiment. We conclude that when Bos indicus × Bos taurus beef heifers are synchronized with new DIB devices and ECP, higher pregnancy rates are obtained in heifers undergoing FTAI late (between 53 to 60 h after DIB removal) than in those undergoing FTAI early (48 to 49 h after DIB removal). However, time of insemination does not apparently affect pregnancy rates when Bos indicus × Bos taurus beef heifers are synchronized with previously used DIB devices and ECP.



2005 ◽  
Vol 17 (2) ◽  
pp. 234 ◽  
Author(s):  
R. Tribulo ◽  
E. Balla ◽  
L. Cutaia ◽  
G.A. Bo ◽  
P.S. Baruselli ◽  
...  

Although several studies have investigated the relationship between circulating progesterone and pregnancy rates in cattle, the beneficial effect of treatments that increase progesterone concentrations, by insertion of a progesterone (P4) releasing device or induction of an accessory CL with hCG, GnRH, or LH treatment, has resulted in inconsistent effects on pregnancy rates in embryo recipients. An experiment was designed to evaluate the effect of hCG or GnRH treatment, given at the time of embryo transfer without estrus detection, on pregnancy rates in recipients treated with intrauterine P4-releasing devices, estradiol benzoate (EB), and eCG. The experiment was performed in two replicates; non-lactating Bos taurus × Bos indicus crossbred beef cows with a body condition score between 2.5 to 3.5 (1-to-5 scale) were used (replicate 1, n = 180; replicate 2, n = 140). All cows received 1 g of P4 via a P4-releasing device (DIB, Syntex, Argentina) and 2 mg EB i.m. (Syntex) on Day 0, and 400 IU of eCG i.m. (Novormon 5000, Syntex) plus 150 μg d(+)cloprostenol i.m. (Ciclase, Syntex) on Day 5. DIBs were removed on Day 8 and all cows received 1 mg EB i.m. on Day 9. Recipients were not observed for signs of estrus, and those >1 CL, or a single CL with an area >256 mm2, received 195 Grade 1 and 46 Grade 2 frozen/thawed “direct transfer” embryos on Day 17. At the time of embryo transfer, recipients were randomly allocated to 1 of 3 treatment groups to receive 1500 IU hCG (Ovusyn, Syntex), 50 μg Lecirelina (GnRH, Gonasyn, Syntex), or no treatment (control) at that time. Ovarian ultrasonography was performed on Day 0 to determine ovarian status (only cows with a CL or a follicle >10 mm and uterine tone were used), on Day 17 to measure CL area, and 40 days after embryo transfer to determine pregnancy status. Data were analyzed by logistic regression and the effects of replication, technician, treatment, and embryo quality were considered in the model. From the 320 recipients treated with a DIB plus EB and eCG, 241 (75.3%) were selected to receive an embryo. Nine (3.7%) and 1 (0.4%) of the selected recipients had 2 and 3 CL, respectively. Pregnancy rates did not differ between replicates (replicate 1: 80/140, 57.1%; and replicate 2: 57/101, 56.4%; P = 0.84), technicians (technician 1: 65/118, 55.1%; and technician 2: 72/123, 58.5%; P = 0.64), or treatments (hCG: 43/80, 53.8%; GnRH: 45/83, 54.2%; and control: 49/78, 62.8% P = 0.99). However, pregnancy rates were higher (P = 0.001) in recipients receiving Grade 1 embryos (121/195, 62.1%) than in those receiving Grade 2 embryos (16/46, 34.8%). GnRH or hCG treatment at the time of embryo transfer did not increase pregnancy rates in recipients synchronized with P4 releasing devices, EB, and eCG. Research was supported by Syntex S.A., Estancia El Mangrullo S.A., and Agencia Cordoba Ciencia S.E.



2004 ◽  
Vol 16 (2) ◽  
pp. 127 ◽  
Author(s):  
G.A Bo ◽  
L. Cutaia ◽  
P. Chesta ◽  
D. Moreno

Treatments with progesterone (P4) releasing devices and estradiol benzoate (EB) have been extensively used in fixed-time AI (FTAI) programs in beef cattle. However, pregnancy rates in postpartum cows kept on pasture often have been lower than expected because of poor body condition score (BCS) and a high incidence of anestrous. A recent study (Cutaia L et al., 2003 Theriogenology 59, 216) suggested that the addition of eCG to a P4/EB FTAI program may improve pregnancy rates in cows with fair to poor BCS, but results were not conclusive. Therefore, this experiment was designed to further investigate the effect of eCG treatment on pregnancy rates in postpartum beef cows in those conditions. The experiment was performed at 2 locations with lactating Angus cows (n=93), 60 to 90d postpartum with a BCS 1.9 (1 to 5 scale; Location 1), and crossbred Zebu cows (n=290), 60 to 90d postpartum with a BCS 2.0 (Location 2). In each Location, cows were randomly allocated to 1 of the following treatment groups: Control, eCG Day6, or eCG Day8. All cows received a P4 intravaginal device (DIB, Syntex, Argentina) and 2mg EB i.m. (Syntex) on Day0, 500mg cloprostenol (Estroplan, Syntex) at the time of DIB removal (Day8), 1mg EB i.m. on Day9 and FTAI 52 to 56h after DIB removal. Cows in the Control group received no further treatment, whereas cows in the eCG-treated groups received 400 IU eCG (Novormon 5000, Syntex) on Day6 or Day8. Cows were examined on Day0 by rectal palpation (Location 1) or by ultrasonography (US; Location 2) and were classified as those with a CL or without a CL, with either large (>8mm) or small (<8mm)small follicles. Pregnancy was determined by US 45d after FTAI. Data were analyzed by logistic regression and the effects of location, treatment, ovarian status, AI technician and semen were considered in the model. There was no effect of location (P=0.3), AI technician (P=0.2) or semen (P=0.8) on pregnancy rates. However, there was an effect of treatment (P=0.02), attributed to higher pregnancy rates in the eCG Groups than in the Control Group (Table). Furthermore, cows with a CL or without a CL but with large follicles on Day 0 had higher pregnancy rates than those with small follicles (P=0.04). It was concluded that the use of eCG in a P4/EB FTAI program improved pregnancy rates in postpartum beef cows that were in fair topoor BCS.



2005 ◽  
Vol 17 (2) ◽  
pp. 157
Author(s):  
L. Cutaia ◽  
E. Balla ◽  
C. Rizzi ◽  
L. Peres ◽  
G.A. Bo

Although treatments with progesterone (P4)-releasing devices and estradiol benzoate (EB) have been extensively used in fixed-time AI (FTAI) programs in beef cattle, pregnancy rates in postpartum Bos indicus cows kept on pasture often have been lower than expected because of poor body condition score (BCS) and a high incidence of anestrus. Temporary weaning and eCG treatment have been shown to increase pregnancy rates in suckled beef cows. Therefore, this experiment was designed to compare the effect of eCG treatment and temporary weaning on pregnancy rates in postpartum cows in fair to poor BCS. Lactating multiparous crossbred Bos indicus cows (n = 393), 60 to 90 d postpartum with a BCS 2.0 (1 to 5 scale) were randomly allocated to 1 of 4 treatment groups, in a 2 × 2 factorial design. At the beginning of the experiment (Day 0), all cows received a P4 intravaginal device (DIB, Syntex, Argentina) and 2 mg EB i.m. (Syntex). On Day 8, DIB devices were removed and all cows received 150 μg D (+) cloprostenol i.m. (Ciclase, Syntex) and were randomly divided to receive 400 IU eCG (Novormon 5000, Syntex) or no treatment at the same time. Furthermore, half of the cows in each treatment group have their calves weaned temporarily, from the time of DIB removal until the end of the FTAI, whereas the other half remained with their calves all the time. Finally, all cows received 1 mg EB i.m. on Day 9 and were FTAI 52 to 56 h after DIB removal. Cows were examined by ultrasonography 42 d after FTAI to determine pregnancy status. Data were analyzed by logistic regression and the effects of treatment and semen used were considered in the model. Ovarian activity was estimated by rectal palpation on Day 0: there were 72/393 (18.2%) cows with a CL, 140/393 (35.6%) cows with palpable medium size follicles, and 181/393 (46.1%) cows with ovaries containing no detectable structures. There was no effect of ovarian status at the time of treatment (P = 0.91) or semen (P = 0.91) on pregnancy rates. Treatment with eCG tended (P = 0.08) to increase pregnancy rates (94/192, 48.9% and 79/201, 39.3% for cows treated or not treated with eCG, respectively). However, there was no effect of weaning or eCG by weaning interaction (P = 0.98) on pregnancy rates (86/191, 45.1% and 87/202, 43.1% for cows that have their calves weaned or not weaned for 56 h, respectively). Results confirm those of previous studies that demonstrated that the use of eCG in a P4/EB/FTAI program improved pregnancy rates in postpartum Bos indicus crossbred cows that were in fair-to-poor BCS. However, no improvement in pregnancy rates was observed after temporary weaning in the present study. Research was supported by Syntex S.A., Estancia El Mangrullo S.A., and Agencia Cordoba Ciencia S.E.



2007 ◽  
Vol 19 (1) ◽  
pp. 220
Author(s):  
G. A. Bo ◽  
L. C. Peres ◽  
D. Pincinato ◽  
M. de la Rey ◽  
R. Tribulo

An experiment was designed to evaluate the effect of the interval between thawing to deposition of the embryo into the uterine horn on pregnancy rates of in vivo-produced frozen–thawed embryos in 1.5 M ethylene glycol (direct transfer). Data were collected from 1122 embryo transfers performed in the same farm (Estancia El Mangrullo, Lavalle, Santiago del Estero, Argentina) during the spring and summer of 2004/05 and 2005/06 (6 replicates, ambient temperature between 20 and 40�C). Recipients used in all replicates were non-lactating, cycling, multiparous Bos taurus � Bos indicus crossbred cows with body condition score between 3 and 4 (1 to 5 scale) that were synchronized using fixed-time embryo transfer protocols. Briefly, the synchronization treatments consisted of the insertion of a Crestar ear implant (Intervet, Sao Paulo, Brazil) or a progesterone-releasing device (DIB; Syntex SA, Buenos Aires, Argentina), plus 2 mg of estradiol benzoate (EB; Syntex) intramuscularly (IM) on Day 0, and 400 IU of eCG (Folligon 5000; Intervet, or Novormon 5000; Syntex) IM plus 150 �g d-cloprostenol IM (Preloban; Intervet, or Ciclase; Syntex) on Day 5. Progestin devices were removed on Day 8 and all cows received 1 mg of EB IM on Day 9. All cows were examined by ultrasonography on Day 16 and those with a luteal area >76 mm2 (by calculating the area of the CL minus the area of the cavity) received, on Day 17, frozen–thawed embryos by nonsurgical transfer. All embryos were Grade 1, and all were frozen in 1.5 M ethylene glycol at the Embryo Plus Laboratory (Brits, South Africa). After being stored in liquid nitrogen, the embryos were plunged directly (no air thawing) in a 30�C water bath for 30 s, and then transferred to the recipient cows by either one of two technicians. Based on the interval between thawing and transfer, the transfers were classified as being in one of 3 groups: Group 1: <3 min; Group 2: 3 to 6 min; and Group 3: 6 to 16 min. The main reason for delayed transfers beyond 6 min was the replacement of one recipient for another because of difficulty in threading the cervix (1% of the total transfers) or a recipient falling down into the chute or with very bad disposition and behavior. Pregnancy was determined by ultrasonography 28 to 35 days after fixed-time embryo transfer, and data were analyzed by logistic regression. There were no effects of replicate, technician, CL area, recipient body condition score, embryo stage, and time from thawing to transfer on pregnancy rates. Pregnancy rates in the 3 thawing to transfer intervals were: Group 1: 215/385, 55.8%; Group 2: 372/655, 56.8%; Group 3: 42/82, 51.2%; P > 0.6. These results may be interpreted to suggest that there is no significant effect of time from thawing to transfer (up to 16 min) in direct transfer embryos using Bos taurus � Bos indicus recipients transferred at a fixed time.



2004 ◽  
Vol 16 (2) ◽  
pp. 212
Author(s):  
L.F. Nasser ◽  
E.L. Reis ◽  
A.M. Oliveira ◽  
G.A. Bo ◽  
P.S. Baruselli

It has been shown recently that treatments with progesterone (P4)-releasing devices combined with estradiol benzoate (EB) plus P4 on Day 0, eCG and PGF on Day 5 and a second application of EB one day after device removal (Day 9) can be used successfully to transfer bovine embryos at a self-appointed time, without the necessity of estrus detection. Although the treatment solved one of the major problems in recipient management, estrus detection, it requires handling the recipients at least five times for treatments and embryo transfer. An experiment was designed to evaluate whether reducing one day of handling, by the administration of eCG and PGF at the time of removal of the P4 device (Day 8), results in comparable pregnancy rates than giving eCG on Day 5. A secondary objective was to determine the effect of injectable P4 at the time of device insertion plus EB treatment. Crossbred Bos taurus×Bos indicus beef heifers (n=301) were randomly assigned to 4 treatment groups in a 2 by 2 factorial design. All Heifers received a P4 device (DIB, Syntex, Argentina) plus 2mg EB i.m. (Syntex) at unknown stages of the estrous cycle (Day 0), with or without 50mg of P4 given i.m. at the same time. Heifers were further subdivided to receive PGF (0.150mg d-cloprostenol, Prolise, Tecnopec, Sao Paulo, Brazil) and 400IU of eCG (Novormon, Syntex) i.m. on Days 5 or 8. In all heifers, DIB devices were removed on Day 8 and 1 mg EB was administered i.m. on Day 9. Day 10 was arbitrarily considered as the day of estrus. On Day 17, heifers were bled for plasma P4 concentrations and examined by ultrasonography to determine the number of CL and their diameter. Heifers that had >1 CL or a single CL with diameter ≥18mm received an in vitro-produced (IVP) embryo by nonsurgical transfer performed by the same veterinarian. Pregnancy rates were determined by ultrasonography 30 days later. The effects of Day of eCG administration (Day 5 or Day 8), P4 of treatment (E2 or E2+P4) and the day-by-P4 treatment interaction on the numbers of CL and plasma P4 were analyzed by ANOVA, and the proportion of recipients selected and pregnant were analyzed using non-parametric tests (NPAR1WAY, SAS). There was no significant effect of P4 treatment or the P4-by-day of eCG interaction in any of the parameters evaluated. However, there was a significant effect of day of eCG administration on plasma P4 concentrations (Day 5=2.4±0.3 v. Day 8=1.7±0.2; P=0.03) and the number of CL (Day 5=1.4±0.1 v. Day 8=1.1±0.0; P=0.02) on Day 17. Furthermore, the proportion of recipients pregnant/treated tended (P=0.1) to be higher in heifers in the Day 5 Group (71/151, 47.0%) than in those in the Day 8 Group (61/150, 40.7%). Although delaying the eCG and PGF administration from Day 5 to Day 8 saves one trip through the chute for treatments, it resulted in lower plasma P4 concentrations and tended to decrease pregnancy rates in bovine embryo recipients synchronized with DIB devices and EB and transferred at a fixed time. Furthermore, the administration of injectable P4 at the time of DIB insertion did not affect pregnancy rates.



2007 ◽  
Vol 19 (1) ◽  
pp. 224
Author(s):  
L. C. Peres ◽  
D. Pincinato ◽  
L. Cutaia ◽  
R. Tribulo ◽  
G. A. Bo

An experiment was designed to evaluate alternative treatment protocols for fixed-time embryo transfer (FTET) in recipients in order to reduce cattle handling. Non-lactating, cycling Bos taurus � Bos indicus beef cows (n = 918), with a body condition score (BCS) of 2.5 to 3.5 out of 5, received a progesterone-releasing device (DIB; Syntex, Buenos Aires, Argentina) and 2 mg estradiol benzoate (EB; Syntex) IM on random days of the cycle (Day 0); DIB were removed on Day 8. Cows were placed randomly into 6 treatment groups in a 3 � 2 factorial design. The factors evaluated were time of administration of PGF and eCG [control treatment: PGF Day 5 and eCG Day 5 (Bo et al. 2002 Theriogenology 57, 53–72); PGF Days 0 and 8 and eCG Day 5; PGF Days 0 and 8 and eCG Day 8] and the time of administration of the second injection of EB (at DIB removal or 24 h later). Therefore, cows in the control treatment received 150 �g of d-Cloprostenol (PGF, Ciclase; Syntex) and 400 IU eCG (Novormon; Syntex) on Day 5, whereas cows in the other 2 treatments received 75 �g of PGF on Days 0 and 8 and 400 IU eCG on either Day 5 or Day 8. Each treatment group was further subdivided to receive 1 mg EB IM on either Day 8 (EB Day 8) or Day 9 (EB Day 9). All recipients, whether observed in estrus or not and with more than one CL with luteal area (total CL area minus cavity area) >76 mm2 on the day before embryo transfer, received frozen-thawed embryos (IETS Grade 1) on Day 16 (EB Day 8) or Day 17 (EB Day 9) by direct transfer. Pregnancy was determined by ultrasonography 30 days after FTET. Continuous data were analyzed by ANOVA and pregnancy rates were analyzed by logistic regression. No effects of body condition score or technician were detected (P > 0.1). Although there were no differences in conception rates between recipients treated with EB on Day 8 or Day 9 (168/321, 52.3% vs. 203/350, 58.0%, respectively; P > 0.1), treatment with EB on Day 8 resulted in fewer recipients selected/treated (321/460, 69.7% vs. 350/458, 76.4%; P < 0.05) and pregnant/treated (168/460, 36.5% vs. 203/458, 44.3%; P < 0.05) than 24 h later (EB Day 9), respectively. The mean interval from DIB removal to estrus was shorter (P < 0.05) for recipients in the EB Day 8 (28.1 � 7.2 h) than in the EB Day 9 (43.5 � 9.4 h) group, and the mean (� SEM) CL area was also less in the EB Day 8 group than in the EB Day 9 group (261.7 � 96.7 vs. 293.1 � 114. mm2; P < 0.05). The number of recipients selected/treated was higher in the group receiving PGF on Days 0 and 8 and eCG on Day 8 (243/305, 79.6%) than in the group receiving PGF on Days 0 and 8 and eCG on Day 5 (208/301, 69.1%) or the control group (220/312, 70.5%). Although the luteal area was greater (P < 0.05) in the PGF on Days 0 and 8 and eCG on Day 5 group (304.4 � 127.1 mm2) than in the groups receiving PGF and eCG on Day 5 (274.6 � 98.6 mm2) or PGF on Days 0 and 8 and eCG Day 8 (258.4 � 90.2 mm2), pregnancy rates did not differ between PGF and eCG treatment groups (P > 0.05). It was concluded that it may be possible to reduce animal handling by treating recipients with a half dose of PGF at the time of DIB insertion and removal, when eCG is also administered, without compromising pregnancy rates.



2021 ◽  
Vol 99 (Supplement_3) ◽  
pp. 48-48
Author(s):  
Alice Brandão ◽  
Reinaldo F Cooke ◽  
G Cliff C Lamb ◽  
José Luiz Vasconcelos ◽  
Ky G Pohler

Abstract Responses of Bos taurus (BT) and B. indicus (BI) beef cows were compared according to their body condition score (BCS) at initiation of breeding season. Cows were assigned to an estrus synchronization + AI protocol and classified as BCS < 5.0 (LBCS, BT, n = 158; BI, n = 248) or BCS ≥ 5.0 (HBCS; BT, n = 173; BI, n = 122). Pregnancy status was verified via transrectal ultrasonography at 30 and 40 d after AI for BI and BT cows, respectively. All BT cows were exposed to natural service for 50 d (beginning 18 d after AI), and all non-pregnant BI cows were immediately exposed to natural service for 60 d. Pregnancy rates to AI did not differ (P ≥ 0.16) between HBCS or LBCS cows (60.9 vs. 53.5% for BT; 37.0 vs. 31.4% for BI; respectively). Pregnancy rates to natural service were greater (P = 0.03) in HBCS BT cows compared with LBCS (82.7 vs. 67.9%; respectively) but did not differ in BI cows (78.9 vs. 71.5%; respectively). Calving rate was greater (P < 0.03) in HBCS cows, which also calved earlier (P < 0.01) compared with LBCS (93.7 vs. 85.1% in BT, 83.6 vs. 73.3% in BI; respectively). HBCS Cows weaned more (P ≤ 0.05) calves compared with LBCS, which were older (P ≤ 0.04) (215 vs. 211 d in BT, 219 vs. 209 d in BI; respectively) and heavier (P ≤ 0.09) at weaning (258 vs. 252 kg in BT, 213 vs. 203 d in BI; respectively). Lastly, kg of calf weaned/cow was greater (P ≤ 0.03) in HBCS cows compared with LBCS (221 vs. 200 d in BT, 159 vs. 129 d in BI; respectively). Therefore, HBCS cows had greater reproductive efficiency and overall productivity, and this was observed in both BT and BI.



2006 ◽  
Vol 18 (2) ◽  
pp. 114
Author(s):  
L. Cutaia ◽  
M. Aviles ◽  
F. Feresin ◽  
A. Franzoni ◽  
L. Peres ◽  
...  

Three experiments were conducted to compare pregnancy rates in cows and heifers treated with intravaginal progesterone (P4)-releasing devices impregnated with either 0.5 or 1.0 g of P4 and inseminated at a fixed time (FTAI). In Experiment 1, 102 postpartum beef cows (Hereford and Angus crossbred with Tuli, 60 to 90 d postpartum) with a body condition score (BCS) of 2.5 to 3.0 (1 to 5 scale) were used. On Day 0, all cows received 2 mg of estradiol benzoate (EB; Syntex, Argentina) i.m. and were randomly assigned to receive an intravaginal progesterone-releasing device with 0.5 g of P4 (DIB 0.5 g; Syntex) or 1.0 g of P4 (DIB 1.0 g; Syntex). On Day 7, DIB devices were removed and all cows received 150 µg D(+)cloprostenol (Ciclase; Syntex) i.m. On Day 8, all cows received 1 mg EB and were FTAI 52 to 56 h after DIB removal. In Experiment 2, 93 Holstein cows that were 90 to 110 days in milk (DIM), producing on average 5000 kg of milk per lactation and with a BCS of 2.5 to 3.0 received the same treatments as those in Experiment 1. In Experiment 3, 100 Holstein heifers, 20 to 22 months old, with a BCS of 2.5 to 3.0, also received the same treatments as those in Experiment 1. Pregnancy rates in all experiments were determined by ultrasonography 35 days after FTAI and compared by chi-square test. No differences in pregnancy rates were detected between lactating beef cows, dairy cows, or dairy heifers treated with DIB devices impregnated with 0.5 or 1.0 g of P4 (Table 1). It was concluded that vaginal P4 releasing devices impregnated with 0.5 g or 1.0 g of P4 results in comparable pregnancy rates in FTAI protocols in beef and dairy cattle. Table 1. Pregnancy rates in postpartum beef cows, Holstein cows, and Holstein heifers treated with DIB devices impregnated with 0.5 or 1.0 g of P4 and subjected to FTAI



2005 ◽  
Vol 17 (2) ◽  
pp. 229 ◽  
Author(s):  
G.A. Bo ◽  
E. Balla ◽  
L. Cutaia ◽  
L. Peres ◽  
P.S. Baruselli ◽  
...  

Although treatments with progesterone (P4) releasing devices, estradiol benzoate (EB) and eCG have been shown to result in acceptable pregnancy rates after embryo transfer, the treatment requires that the cows be run through the chute at least four times for treatments. An experiment was designed to compare pregnancy rates in cows treated with P4 releasing devices plus EB and eCG, and induced to ovulate with EB given at device removal or 24 h later. Non-lactating Bos taurus × Bos indicus crossbred beef cows (n = 165), with a body condition score between 2.5 to 3.5 (1 to 5 scale), were treated with a P4-device (DIB, Syntex, Argentina) and 2 mg EB i.m. (Syntex), on Day 0 and 400 IU of eCG i.m. (Novormon, Syntex) plus 150 μg D(+)cloprostenol i.m. (Ciclase, Syntex) on Day 5. On Day 8, DIB devices were removed and cows were randomly divided into two groups to receive either 1 mg EB i.m. at the time of DIB removal (EB0) or 24 h later (Day 9; EB24). Recipients were observed for signs of estrus for 48 h after DIB removal. On Day 16, all recipients observed in estrus and with >1 CL or a single CL with an area >256 mm2 were selected to receive fresh embryos on Day 16 (EB0) or Day 17 (EB24). Furthermore, 20 recipients not observed in estrus but with a CL >256 mm2 were randomly selected and transferred. The embryos used were 28 Grade 1, 40 Grade 2, and 24 Grade 3. Ovarian ultrasonography was performed on Day 0, to determine ovarian status (only cows with a CL or a follicle >10 mm and uterine tone were used), on Day 16 to measure CL area, and 60 days after embryo transfer to determine pregnancy status. Quantitative data were analyzed by Student's t-test and qualitative data were analyzed by logistic regression. There were no differences between groups in the mean (± SEM) CL area on Day 16 (EB0: 300.3 ± 12.0 mm2 and EB24: 324.9 ± 11.7 mm2; P = 0.14), the proportion of recipients in estrus (EB0: 38/82, 46.3%, and EB24: 34/83, 41.0%; P = 0.49), the number of recipients with >1 CL or a CL >256 mm2 (EB0: 68/82, 82.9%, and EB24: 72/83, 86.7%; P = 0.49) and the number of recipients pregnant/transferred (EB0: 31/49, 63.4%, and 20/43, 46.5%; P = 0.23). Furthermore, there were no significant effects of embryo quality (P = 0.31) or technician (P = 0.12) on pregnancy rates. The mean interval from DIB removal to estrus was shorter (P = 0.001) for recipients in the EB0 group (22.7 ± 1.0 h) than for those in the EB24 group (37.4 ± 1.2 h). Nevertheless, pregnancy rates did not differ (P = 0.14) between recipients seen in estrus (EB0: 21/38, 55.3%, and EB 24: 16/34, 47.1%) and those not seen in estrus but with a CL >256 mm2 on Day 16 (EB0: 10/11, 90.9%, and EB24 4/9, 44.4%). It was concluded that the two treatments evaluated are equally efficacious for synchronizing Bos taurus × Bos indicus recipients. Furthermore, the use of EB at device removal could reduce the number of trips through the chute without affecting pregnancy rates. Research was supported by Syntex S.A., Estancia El Mangrullo S.A., and Agencia Cordoba Ciencia S.E.



Sign in / Sign up

Export Citation Format

Share Document