Prevalence of porA pseudogene deletion among Neisseria gonorrhoeae isolates referred to the UK’s Gonococcal Resistance to Antimicrobials Surveillance Program

Sexual Health ◽  
2017 ◽  
Vol 14 (4) ◽  
pp. 392 ◽  
Author(s):  
Martina Toby ◽  
Pamela Saunders ◽  
Michelle Cole ◽  
Vlad Grigorjev ◽  
Sarah Alexander ◽  
...  

porA pseudogene-negative Neisseria gonorrhoeae isolates produce false-negative results when examined by polymerase chain reaction (PCR) with porA pseudogene targets. In the present study, 533 representative gonococcal isolates received in 2011 via the Gonococcal Resistance to Antimicrobials Surveillance Program were examined to determine the prevalence of porA-negative isolates. Less than 0.4% (2/533) of isolates were found to be reproducibly negative with the porA real-time PCR but were confirmed as N. gonorrhoeae with molecular, biochemical and immunological confirmatory tests. Sequencing revealed both isolates contained the Neisseria meningitidis porA gene. Low prevalence indicates that although these isolates do not present a major public health problem, microbiologists should remain vigilant.

2012 ◽  
Vol 54 (5) ◽  
pp. 245-248 ◽  
Author(s):  
Maria Cristina Carvalho do Espírito-Santo ◽  
Mónica Viviana Alvarado-Mora ◽  
Pedro Luiz Silva Pinto ◽  
Flair José Carrilho ◽  
João Renato Rebello Pinho ◽  
...  

Schistosomiasis constitutes a major public health problem, with an estimated 200 million individuals infected worldwide and 700 million people living in risk areas. In Brazil there are areas of high, medium and low endemicity. Studies have shown that in endemic areas with a low prevalence of Schistosoma infection the sensitivity of parasitological methods is clearly reduced. Consequently diagnosis is often impeded due to the presence of false-negative results. The aim of this study is to present the PCR reamplification (Re-PCR) protocol for the detection of Schistosoma mansoni in samples with low parasite load (with less than 100 eggs per gram (epg) of feces). Three methods were used for the lysis of the envelopes of the S. mansoni eggs and two techniques of DNA extraction were carried out. Extracted DNA was quantified, and the results suggested that the extraction technique, which mixed glass beads with a guanidine isothiocyanate/phenol/chloroform (GT) solution, produced good results. PCR reamplification was conducted and detection sensitivity was found to be five eggs per 500 mg of artificially marked feces. The results achieved using these methods suggest that they are potentially viable for the detection of Schistosoma infection with low parasite load.


2014 ◽  
Vol 19 (8) ◽  
Author(s):  
D Luijt ◽  
C Di Lorenzo ◽  
A M van Loon ◽  
M Unemo

We describe the results of the Quality Control for Molecular Diagnostics 2013 Neisseria gonorrhoeae external quality assessment programme that included an N. gonorrhoeae strain harbouring an N. meningitidis porA gene which causes false-negative results in molecular diagnostic assays targeting the gonococcal porA pseudogene. Enhanced awareness of the international transmission of such gonococcal strains is needed to avoid false-negative results in both in-house and commercial molecular diagnostic assays used in laboratories worldwide, but particularly in Europe.


Biomedika ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 23-30
Author(s):  
Mustika Sari Hutabarat ◽  
Firdaus Hamid ◽  
Irawaty Djaharuddin ◽  
Alfian Zainuddin ◽  
Rossana Agus ◽  
...  

Streptococcus pneumoniae (pneumococcus) is a Gram-positive facultative anaerobic bacterium that is a major cause of morbidity and mortality worldwide. But the lack of reporting of disease by this bacterium in Indonesia, one of the causes is because the diagnosis of pneumococcal infection is often clinically not typical and conventional methods which are still the standard gold method often give false-negative results. So the purpose of this study was to evaluate the performance of culture and molecular diagnostic methods using the Polymerase Chain Reaction (PCR) technique in detecting Streptococcus pneumoniae in sputum clinical samples using the Autolysin (LytA) gene which is a virulence factor of this bacterium. 57 isolates from 60 samples were confirmed as Streptococcus sp through microscopic identification, culture, and biochemical tests. Then the sensitivity test with an optochin test of 9 (9%) compared the results descriptively with the PCR technique using the Autolysin A (LytA) gene which was obtained more sensitive by 15 (25%).


2012 ◽  
Vol 17 (9) ◽  
Author(s):  
D Golparian ◽  
E Johansson ◽  
M Unemo

We describe a Neisseria gonorrhoeae strain, found in Sweden in 2011, that harbours a N. meningitidis porA gene causing false-negative results in PCRs targeting the gonococcal porA pseudogene. Furthermore, the strain had no prolyliminopeptidase (PIP) activity that many commercial biochemical kits for species verification in culture rely on. Enhanced awareness of the spread of such strains and screening for them can be crucial.


2003 ◽  
Vol 15 (3) ◽  
pp. 268-273 ◽  
Author(s):  
Magdalena Jacobson ◽  
Stina Englund ◽  
András Ballagi-Pordány

Lawsonia intracellularis is an intracellular organism that causes proliferative enteritis in pigs. This bacterium is difficult to culture, and antemortem demonstration of the microbe is therefore often performed on fecal samples by polymerase chain reaction (PCR). Polymerase chain reaction is sensitive and specific, but inhibitory factors in feces might cause false-negative results. This article describes the construction and use of an internal standard, a mimic. The mimic is amplified by the same primers as those used for L. intracellularis DNA and thus could indicate false-negative results in clinical samples. The amplicon was clearly visible when as few as 10 mimic molecules were added per amplification reaction and when no inhibitors were present. When fecal samples were spiked with the mimic, the detection limit was 102 molecules per PCR. Sixty clinical samples, 20 from wild boars, 20 from growing pigs with diarrhea, and 20 from pigs without diarrhea, were prepared by a boiling procedure and subjected to PCR together with 103 mimic molecules. Nine samples were positive, of which 7 originated from pigs with diarrhea and 2 from pigs without diarrhea. In 14 samples from wild boars, in 8 samples from pigs without diarrhea, and in 3 samples from pigs with diarrhea, neither the mimic nor the target DNA was visible. This indicated the presence of inhibitors in these samples. It is concluded that the mimic can be used as an internal control in the diagnosis of L. intracellularis to indicate inhibition of PCR.


2020 ◽  
Vol 9 (3) ◽  
pp. 408-410
Author(s):  
Fatemeh Bahreini ◽  
Rezvan Najafi ◽  
Razieh Amini ◽  
Salman Khazaei ◽  
Saeid Bashirian

As the SARS-CoV-2 (COVID-19) pandemic spreads rapidly, there is need for a diagnostic test with high accuracy to detect infected individuals especially those without symptoms. Real-time polymerase chain reaction (RT-PCR) is a common molecular test for diagnosing SARS-CoV-2. If some factors are not taken into consideration when performing this test, it can have a relatively large number of false negative results. In this article, we discuss important considerations that could lead to false negative test reduction. Key words: • SARS-CoV-2 • COVID-19 • Real time polymerase chain reaction • RT-PCR test • Diagnosis • False negatives • Genetics • Emerging disease   Copyright © 2020 Bahreini et al. Published by Global Health and Education Projects, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0)which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in this journal, is properly cited.


Author(s):  
Marco Marando ◽  
Adriana Tamburello ◽  
Pietro Gianella

On 11 March 2020, the WHO declared COVID-19 a pandemic and global health emergency. We describe the clinical features and role of ultra-low-dose chest computed tomography (CT) and bronchoscopy in the diagnosis of coronavirus disease (COVID-19). In our patient, who was highly suggestive clinically and radiologically for COVID-19, we had two false-negative results for nasopharyngeal and oral swab reverse-transcriptase polymerase chain reaction (RT-PCR) assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Eventually, we confirmed the diagnosis using bronchoscopy and bronchoalveolar lavage (BAL).


2020 ◽  
Author(s):  
Isaac J. Núñez ◽  
Pablo F. Belaunzarán-Zamudio ◽  
Yanink Caro-Vega

Underestimation of the number of cases during the COVID-19 pandemic has been a constant concern worldwide. Case confirmation is based on identification of SARS-CoV-2 RNA using real time polymerase chain reaction (RT-PCR) in clinical samples. However, these tests have suboptimal sensitivity, especially during the early and late course of infection. Using open data, we estimated that among 1 343 730 people tested in Mexico since February 27th, there were 838 377 (95% CL 734 605 - 1 057 164) cases, compared with 604 376 considering only positive tests. ICU admissions and deaths were around 16% and 9% higher than reported. Thus, we show that accounting for the sensitivity of SARS-Cov-2 RT-PCR diagnostic tests is a simple way to improve estimations for the true number of COVID-19 cases in tested people, particularly in high-prevalence populations. This could aid to better inform public health measures and reopening policies.


Sign in / Sign up

Export Citation Format

Share Document