A Stability Indicating High Performance Liquid Chromatographic Assay of Isradipine in Pharmaceutical Preparations

1996 ◽  
Vol 29 (7) ◽  
pp. 1157-1165 ◽  
Author(s):  
Maha F. A. Elghany ◽  
Badr E. Elzeany ◽  
Mohammed A. Elkawy ◽  
James T. Stewart
2007 ◽  
Vol 90 (6) ◽  
pp. 1547-1553 ◽  
Author(s):  
Alaa Khedr

Abstract The purpose of this work was to develop a sensitive, selective, and validated stability-indicating high-performance liquid chromatographic (LC) assay of atorvastatin (ATV) in bulk drug and tablet form. ATV was subjected to different stress conditions, including UV light, oxidation, acid-base hydrolysis, and temperature. ATV and its degradation products were analyzed on an Agilent Zorbax XDB C18 column using isocratic elution with acetonitrile0.02 M sodium acetate, pH 4.2 (45 + 55, v/v) for 25 min. The samples were monitored with fluorescence (FL) detection at 282 nm (excitation)/400 nm (emission). The response ratio of FL to UV detection (at 247 nm) for ATV was 1.66. The method showed good resolution of ATV from its decomposition products. The photodegradation products were separated by silica gel thin-layer chromatography using double development with ethyl acetaten-hexaneglacial acetic acidmethanol (40 + 55 + 0.5 + 4.5, v/v/v/v) followed by (39 + 55 + 0.5 + 5.5, v/v/v/v), and confirmed by LC-FL analysis. The FL response was linear over the investigated range for ATV. The linear range was 101200 ng/injection, and the limit of quantitation was 2.0 ng/injection.


Author(s):  
RAMA KUMAR KANDULA ◽  
RAJA SUNDARARAJAN

Objective: The objective of the study was to develope a stability indicating high-performance liquid chromatographic (HPLC) method for simultaneous assay of pentazocine and naloxone in bulk and tablets. Methods: Pentazocine and naloxone were analyzed on Dionex C18 column using 0.1M K2HPO4 buffer (pH 4.0) and methanol (60:40, v/v) as the mobile phase. The concentration of pentazocine and naloxone was quantified by photodiode array detector set at 248 nm. The method was validated in compliance with ICH rules. Pentazocine and naloxone tablet formulation was subjected to forced degradation such as acid, neutral and alkali hydrolysis, oxidation, photo, and thermal degradation. Results: The method was linear, with R2=0.9999 in the concentration range 100–300 μg/ml for pentazocine and R2=0.9995 in the concentration range 1–3 μg/ml for naloxone. The level of detection and quantification was 0.097 μg/ml and 0.322 μg/ml for pentazocine and 0.0073 μg/ml and 0.0243 μg/ml for naloxone, respectively. The degraded products are resolved well from pentazocine and naloxone with significantly different retention time values. From validation results, it was proved that the method is selective, precise, robust, and accurate for the estimation of pentazocine and naloxone simultaneously. Conclusion: The developed stability-indicating HPLC method can be applied for quantitative determination of pentazocine and naloxone in tablets.


2008 ◽  
Vol 91 (3) ◽  
pp. 557-561 ◽  
Author(s):  
Pankaj K Kachhadia ◽  
Ashish S Doshi ◽  
Hitendra S Joshi

Abstract A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating column high-performance liquid chromatographic (HPLC) assay method was developed and validated for determination of nebivolol in solid pharmaceutical dosage forms. Isocratic RP-HPLC separation was achieved on a Phenomenex Luna C8 (2) column (250 mm 4.6 mm id, 5 m particle size) using mobile phase composed of acetonitrilepH 3.5 phosphate buffer (35 + 65, v/v) at a flow rate of 1.0 mL/min, and detection was performed at 280 nm using a photodiode array detector. The drug was subjected to oxidation, hydrolysis, photolysis, and heat to apply stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness, and solution stability. The method was linear in the drug concentration range of 40160 g/mL with a correlation coefficient of 0.9999. The repeatability relative standard deviation (RSD) for 6 samples was 0.69, and the intermediate precision (RSD) for 6 samples was 1.39. The accuracy (recovery) was between 98.57 and 99.55. Degradation products produced as a result of stress studies did not interfere with detection of nebivolol, and the assay can thus be considered stability-indicating.


Sign in / Sign up

Export Citation Format

Share Document