CPP–ACP pretreatment effect on microshear bond strength of simplified etch-and-rinse adhesive systems plus a flowable composite to enamel

2014 ◽  
Vol 29 (2) ◽  
pp. 109-115
Author(s):  
Diana Ferreira Gadelha de Araújo ◽  
Boniek Castillo Dutra Borges ◽  
Ariza Magalhães Mendes ◽  
Eduardo José Souza-Junior ◽  
Isauremi Vieira de Assunção ◽  
...  
Materials ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 2504
Author(s):  
Mohammad Al-Nabulsi ◽  
Alaa Daud ◽  
Cynthia Yiu ◽  
Hanan Omar ◽  
Salvatore Sauro ◽  
...  

Objective: To evaluate the effect of a new application method of bulk-fill flowable composite resin material on bond-strength, nanoleakage, and mechanical properties of dentine bonding agents. Materials and methods: Sound extracted human molars were randomly divided into: manufacturer’s instructions (MI), manual blend 2 mm (MB2), and manual blend 4 mm (MB4). Occlusal enamel was removed and flattened, dentin surfaces were bonded by Prime & Bond universal (Dentsply and Optibond FL, Kerr). For the MI group, adhesives were applied following the manufacturer’s instructions then light-cured. For MB groups, SDR flow+ bulk-fill flowable composite resin was applied in 2- or 4-mm increment then manually rubbed by a micro brush for 15 s with uncured dentine bonding agents and the mixture was light-cured. Composite buildup was fabricated incrementally using Ceram.X One, Dentsply nanohybrid composite resin restorative material. After 24-h water storage, the teeth were sectioned to obtain beams of about 0.8 mm2 for 24-h and thermocycled micro-tensile bond strength at 0.5 mm/min crosshead speed. Degree of conversion was evaluated with micro-Raman spectroscopy. Contraction gaps at 24 h after polymerization were evaluated and atomic force microscopy (AFM) nano-indentation processes were undertaken for measuring the hardness across the interface. Depth of resin penetration was studied using a scanning electron microscope (SEM). Bond strength data was expressed using two-way ANOVA followed by Tukey’s test. Nanoindentation hardness was separately analyzed using one-way ANOVA. Results: Factors “storage F = 6.3” and “application F = 30.11” significantly affected the bond strength to dentine. For Optibond FL, no significant difference in nanoleakage was found in MI/MB4 groups between baseline and aged specimens; significant difference in nanoleakage score was observed in MB2 groups. Confocal microscopy analysis showed MB2 Optibond FL and Prime & Bond universal specimens diffusing within the dentine. Contraction gap was significantly reduced in MB2 specimens in both adhesive systems. Degree of conversion (DC) of the MB2 specimens were numerically more compared to MS1 in both adhesive systems. Conclusion: Present study suggests that the new co-blend technique might have a positive effect on bond strengths of etch-and-rinse adhesives to dentine.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


10.2341/05-55 ◽  
2006 ◽  
Vol 31 (4) ◽  
pp. 450-455 ◽  
Author(s):  
A. M. Guéders ◽  
J. F. Charpentier ◽  
A. I. Albert ◽  
S. O. Geerts

Clinical Relevance This study indicates that etch and rinse adhesive systems are less prone to microleakage than self-etch systems.


2017 ◽  
Vol 42 (3) ◽  
pp. 284-296 ◽  
Author(s):  
EC Martini ◽  
SO Parreiras ◽  
MF Gutierrez ◽  
AD Loguercio ◽  
A Reis

SUMMARY Objectives: The aim of this study was to investigate the effect of different protocols of 17% ethylene diamine tetra-acetic acid (EDTA) conditioning on the etching pattern and immediate bond strength of universal adhesives to enamel and sclerotic dentin. Methods and Materials: Forty bovine teeth with sclerotic dentin and 20 human third molars were randomly divided into eight groups resulting from the combination of the main factors surface treatment (none, two-minute EDTA conditioning manual application, 30-second EDTA manual application, 30-second EDTA sonic application) and adhesives systems (Scotchbond Universal Adhesive [SBU] and Prime & Bond Elect [PBE]). Resin-dentin and enamel-dentin bond specimens were prepared and tested under the microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests, respectively. The etching pattern produced on the unground enamel and the sclerotic dentin surfaces under the different protocols and adhesive systems was evaluated under scanning electron microscopy. Results: For enamel, only the main factor adhesive was significant (p<0.0001), with SBU showing the highest μSBS. In sclerotic dentin, the lowest mean was observed for the group without EDTA application and the highest mean in the group with EDTA application with the sonic device for 30 seconds. Regardless of the EDTA protocol, the highest means of μTBS were observed for SBU (p<0.05). Conclusions: EDTA conditioning improves the bonding performance of universal adhesives in the self-etch mode on sclerotic dentin, mainly when applied for 30 seconds with the aid of a sonic device. EDTA pretreatment also improves the retentive etching pattern of enamel, but it does not result in higher enamel bond strength.


2017 ◽  
Vol 18 (1) ◽  
pp. 34-38
Author(s):  
Mojtaba Abdollahi ◽  
Masoumeh Ebrahimi ◽  
Alireza Sarraf Shirazi ◽  
Faraneh Abdolhoseinpour

ABSTRACT Introduction One of the possible mechanisms for the gradual destruction of bond strength in dentin-resin interface, could be due to the demineralized unstable collagen matrix. Use of protease inhibitors, such as tannic acid (TA) could prevent destruction of collagen fibers. The aim of this study was to compare the TA effect on bond strength of etch and rinse and self-etch adhesive systems in the dentin of primary teeth. Materials and methods This in vitro study was done on 40 extracted primary molar teeth. The teeth were sectioned in the mesiodistal direction, and enamel of buccal and lingual surfaces was removed. Samples were randomly divided into four groups: Single bond (SB) + TA, SB, Clearfil SE Bond (CSB) + TA, and CSB. Then, Z250 and Clearfil AP-X composites were cured on the surfaces of SB and CSB groups respectively. After that, all samples were divided into aging and non-aging groups. For 3 months, samples were placed under 1,000 thermal cycles in aging group. Subsequently, the shear bond strengths of all groups were measured by the International testing machine, and failure mode was evaluated by an optical stereomicroscope. Data were analyzed with paired t-test and independent t-test. Results Tannic acid induced a significant reduction in the immediate bond strength of adhesive SB. Meanwhile, TA had no significant effect on shear bond strength of the CSB system. Conclusion Based on our findings, use of TA is not recommended with SB and CSB adhesives on primary teeth. Clinical significance Tannic acid may not be considered in resin restorations of primary teeth. How to cite this article Ebrahimi M, Sarraf Shirazi A, Abdolhoseinpour F, Abdollahi M. Effect of Tannic Acid on Bond Strength of Etch and Rinse and Self-etch Adhesive Systems in Dentin of Primary Teeth. J Contemp Dent Pract 2017;18(1):34-38.


Marine Drugs ◽  
2020 ◽  
Vol 18 (5) ◽  
pp. 263 ◽  
Author(s):  
Eugenia Baena ◽  
Sandra R Cunha ◽  
Tatjana Maravić ◽  
Allegra Comba ◽  
Federica Paganelli ◽  
...  

The aim of the present study was to evaluate the effect of 0.1% chitosan (Ch) solution as an additional primer on the mechanical durability and enzymatic activity on dentine using an etch-and-rinse (E&R) adhesive and a universal self-etch (SE) adhesive. Microtensile bond strength and interfacial nanoleakage expression of the bonded interfaces for all adhesives (with or without pretreatment with 0.1% Ch solution for 1 min and air-dried for 5 s) were analyzed immediately and after 10,000 thermocycles. Zymograms of protein extracts from human dentine powder incubated with Optibond FL and Scotchbond Universal on untreated or Ch-treated dentine were obtained to examine dentine matrix metalloproteinase (MMP) activities. The use of 0.1% Ch solution as an additional primer in conjunction with the E&R or SE adhesive did not appear to have influenced the immediate bond strength (T0) or bond strength after thermocycling (T1). Zymography showed a reduction in MMP activities only for mineralized and demineralized dentine powder after the application of Ch. Application of 0.1% Ch solution does not increase the longevity of resin–dentine bonds. Nonetheless, the procedure appears to be proficient in reducing dentine MMP activities within groups without adhesive treatments. Further studies are required to comprehend the cross-linking of Ch with dentine collagen.


Author(s):  
Tubayesha Hassan ◽  
MH Sattar

As a means of regular practice in orthodontics and aesthetic dentistry, resin based adhesive systems are being used exclusively. Keeping up with the ever-increasing demand for aesthetic dental treatment all over the world, newer and more improved adhesive systems have been developed. However, regarding the comparison as to which bonding system performs better in clinical perspective, there is lack of existing scientific review articles. In this review, we tend to explore the conventional etch and rinse bonding system and the self-etch primer bonding system. The different tests to assess and compare bond strength between these two types of adhesives from various bibliography are discussed. The results of shear bond strength test, adhesive remnant index (ARI), enamel-adhesive interface using scanning electron microscope (SEM) and the effect of saliva contamination and time are discussed. Interestingly, each system has its strengths and weaknesses. In shear bond strength, self-etch bonding systems clearly exhibits less strength than conventional bonding systems. Resin tags into enamel surface are shorter in self-etch primer adhesives which results from milder etching to enamel compared to the conventional aid-etch and rinse adhesives. Contrarily, the irreversible changes to enamel surface is more aggressive in conventional acid-etching which states that self-etching systems are better according to the principles of minimal intervention dentistry. Ban J Orthod & Dentofac Orthop, April 2017; Vol-7 (1-2), P.20-26


Sign in / Sign up

Export Citation Format

Share Document