Toric Intraocular Lens Calculation considering anterior Surgically Induced Astigmatism and Posterior Corneal Astigmatism

Author(s):  
Joaquín Fernández ◽  
Manuel Rodríguez-Vallejo ◽  
Carlos Rocha-de-Lossada ◽  
Elisa Hueso ◽  
David Piñero
2018 ◽  
Vol 28 (4) ◽  
pp. 398-405 ◽  
Author(s):  
Joaquín Fernández ◽  
Manuel Rodríguez-Vallejo ◽  
Javier Martínez ◽  
Ana Tauste ◽  
David P Piñero

Purpose: To assess the surgically induced astigmatism with femtosecond laser-assisted and manual temporal clear corneal incisions and to evaluate the performance of a model for prediction of the surgically induced astigmatism based on the preoperative corneal astigmatism. Methods: Clinical data of 104 right eyes and 104 left eyes undergoing cataract surgery, 52 with manual incisions and 52 with femtosecond laser-assisted incisions in each eye group, were extracted and revised retrospectively. In all cases, manual incisions were 2.2 mm width and femtosecond incisions were 2.5 mm width, both at temporal location. A predictive model of the surgically induced astigmatism was obtained by means of simple linear regression analyses. Results: Mean surgically induced astigmatisms for right eyes were 0.14D@65° (manual) and 0.24D@92° (femtosecond) (p > 0.05) and for left eyes, 0.15D@101° (manual) and 0.19D@104° (femtosecond) (p > 0.05). The orthogonal components of the surgically induced astigmatism (XSIA, YSIA) were significantly correlated (p < 0.05) with the preoperative orthogonal components of corneal astigmatism (Xpreop, Ypreop) (r = −0.29 for X and r = −0.1 for Y). The preoperative astigmatism explained 8% of the variability of the XSIA and 3% of the variability of YSIA. The postoperative corneal astigmatism prediction was not improved by the surgically induced astigmatism obtained from the model in comparison with the simple vector subtraction of the mean surgically induced astigmatism. Conclusion: Temporal incisions induce similar astigmatism either for manual or for femtosecond procedures. This can be clinically negligible for being considered for toric intraocular lens calculation due to the great standard deviation in comparison with the mean. The usefulness of the prediction model should be confirmed in patients with high preoperative corneal astigmatism.


2017 ◽  
Vol 2017 ◽  
pp. 1-9
Author(s):  
Pisong Yan ◽  
Zhiyu Du ◽  
Yu Zhang

Purpose. To evaluate the astigmatic outcomes of wavefront-guided sub-Bowman keratomileusis (WFG-SBK) for low to moderate myopic astigmatism.Methods. This study enrolled 100 right eyes from 100 patients who underwent WFG-SBK for the correction of myopia and astigmatism. The polar value method was performed with anterior and posterior corneal astigmatism measured with Scheimpflug camera combined with Placido corneal topography (Sirius, CSO) and refractive astigmatism preoperatively and 1 month, 3 months, and 6 months postoperatively.Results. Similar results for surgically induced astigmatism (SIA) and error of the procedure in both anterior corneal astigmatism (ACA) and total ocular astigmatism (TOA). There was a minor undercorrection of the cylinder in both ACA and TOA. Posterior corneal astigmatism (PCA) showed no significant change.Conclusions. Wavefront-guided SBK could provide good astigmatic outcomes for the correction of low to moderate myopic astigmatism. The surgical effects were largely attributed to the astigmatic correction of the anterior corneal surface. Posterior corneal astigmatism remained unchanged even after WFG-SBK for myopic astigmatism. Polar value analysis can be used to guide adjustments to the treatment cylinder alongside a nomogram designed to optimize postoperative astigmatic outcomes in myopic WFG-SBK.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Kazutaka Kamiya ◽  
Wakako Ando ◽  
Masahide Takahashi ◽  
Nobuyuki Shoji

Abstract Background To compare the arithmetic mean (M-SIA) and the summated vector mean of surgically induced astigmatism (SVM-SIA) according to the incision site after phakic intraocular lens (Visian implantable collamer lens (ICL), STAAR Surgical) implantation. Methods This study comprised 121 eyes of 121 consecutive patients undergoing ICL surgery through a 3.0-mm temporal or superior clear corneal incision. The magnitude and the axis of corneal astigmatism preoperatively and 3 months postoperatively were measured using an automated keratometer. The M-SIA and the SVM-SIA were determined according to the incision site. Results The magnitude of corneal astigmatism significantly increased from 1.23 ± 0.59 D preoperatively to 1.46 ± 0.72 D postoperatively in the temporal incision group (Wilcoxon signed-rank test, P < 0.001), but it significantly decreased from 1.09 ± 0.36 D preoperatively to 0.86 ± 0.41 D postoperatively in the superior incision group (P < 0.001). The M-SIA was 0.48 ± 0.30 D, and the SVM-SIA was 0.23 ± 0.52 D at a meridian of 82° in the temporal incision group. The M-SIA was 0.57 ± 0.30 D, and the SVM-SIA was 0.47 ± 0.45 D at a meridian of 1° in the superior incision group. Conclusions ICL implantation induces the M-SIA by approximately 0.5 D, but the SVM-SIA decreased to 50% and 80% of the M-SIA in magnitude through temporal and superior incisions, respectively. The direction of the SVM-SIA showed a tendency toward corneal flattening to the incisional site. It should be noted that the M-SIA is somewhat different from the SVM-SIA according to the incision site. Trial registration University Hospital Medical Information Network Clinical Trial Registry (000044269)


2021 ◽  
Vol 62 (12) ◽  
pp. 1592-1599
Author(s):  
Joon Kyo Chung ◽  
Gyu Le Han ◽  
Hoon Noh ◽  
Dong Hui Lim ◽  
Tae-Young Chung

Purpose: The purpose of this study was to compare corneal astigmatism correction between “wound open” and “wound intact” methods during femtosecond laser-assisted transepithelial arcuate keratotomy.Methods: From April 2016 to December 2018, a retrospective survey was conducted on patients undergoing femtosecond laser cataract surgery at the Ophthalmology Department of Samsung Medical Center. Size comparison and vector analysis of corneal astigmatism before and after surgery were performed in the wound open and wound intact groups.Results: In the wound open and wound intact groups, the target-induced astigmatism (TIA) was 1.28 ± 0.55; and 1.26 ± 0.29 diopters, the surgically induced astigmatism (SIA) was 0.80 ± 0.52; and 0.53 ± 0.32 diopters, and the correction index (CI) was 0.63 ± 0.28; and 0.43 ± 0.26, respectively. The astigmatism correction was superior in the wound open group (p = 0.048, p = 0.025). In a subgroup with TIA < 1.2 diopters, there were no significant differences in SIA or CI between the two groups; however, in the subgroup with a TIA > 1.2 diopters, the SIA was 1.09 ± 0.59; and 0.54 ± 0.37 diopters and the CI was 0.60 ± 0.28; and 0.36 ± 0.23 in the wound open and wound intact groups, respectively (p = 0.022, p = 0.047). Thus, astigmatism correction was superior in the wound open group.Conclusions: The wound open method during femtosecond laser-assisted transepithelial arcuate keratotomy was superior for astigmatism correction compared to the wound intact method.


Sign in / Sign up

Export Citation Format

Share Document