Numerical Study of Transient and Steady-State Natural Convection and Surface Thermal Radiation in a Horizontal Square Open Cavity

2005 ◽  
Vol 48 (2) ◽  
pp. 179-196 ◽  
Author(s):  
J. F. Hinojosa ◽  
C. A. Estrada ◽  
R. E. Cabanillas ◽  
G. Alvarez
Solar Energy ◽  
2012 ◽  
Vol 86 (4) ◽  
pp. 1118-1128 ◽  
Author(s):  
Moises Montiel Gonzalez ◽  
Jesús Hinojosa Palafox ◽  
Claudio A. Estrada

2019 ◽  
Vol 7 (1) ◽  
pp. 43-53
Author(s):  
Abbas Jassem Jubear ◽  
Ali Hameed Abd

The heat sink with vertically rectangular interrupted fins was investigated numerically in a natural convection field, with steady-state heat transfer. A numerical study has been conducted using ANSYS Fluent software (R16.1) in order to develop a 3-D numerical model.  The dimensions of the fins are (305 mm length, 100 mm width, 17 mm height, and 9.5 mm space between fins. The number of fins used on the surface is eight. In this study, the heat input was used as follows: 20, 40, 60, 80, 100, and 120 watts. This study focused on interrupted rectangular fins with a different arrangement and angle of the fins. Results show that the addition of interruption in fins in various arrangements will improve the thermal performance of the heat sink, and through the results, a better interruption rate as an equation can be obtained.


2019 ◽  
Vol 11 (2) ◽  
pp. 216-228
Author(s):  
Ass. Prof. Dr. Abbas Jassem Jubear ◽  
Ali Hameed Abd

The heat sink with vertically rectangular interrupted fins investigated numerically in a natural convection field, and with steady-state heat transfer. Numerical study has been conducted using ANSYS Fluent software (R16.1) in order to develop a 3-D numerical model.  The dimensions of fins are (305 mm length, 100 mm width, 17 mm height, and 9.5 mm space between fins). The number of fins used on the surface are eight. In this study, the heat input that is  used as follow (20, 40, 60, 80, 100, and 120 watts). The study is focused on interrupted rectangular fins with different arrangement of fins. The results show that the addition of interruption fins in various arrangements will improve the thermal performance of the heat sink, and through the results, a better interruption rate obtained as an equation.                                                         


1998 ◽  
Vol 22 (3) ◽  
pp. 269-289
Author(s):  
M. Lacroix

A numerical study has been conducted for the heat transfer from a discrete heat source by natural convection in air above coupled with conduction dominated melting of a phase change material (PCM) below via a wall of finite thermal diffusivity. Results indicate that the presence of a PCM layer underneath the wall significantly delays the temperature rise of the heat source. The time delay increases as the thermal diffusivity of the wail material decreases and as the thickness of the PCM layer increases. For high thermal conductivity wall materials [Formula: see text] the steady state heat source temperatures are similar and independent of the PCM layer. On the other hand, for [Formula: see text], the steady state temperatures are higher and dependent on the thickness of the PCM layer. A correlation is proposed in terms of the thickness of the PCM layer and the thermal conductivity ratio of the wall.