Radiation exposure to operator and patients during cardiac electrophysiology study, radiofrequency catheter ablation and cardiac device implantation procedures

2015 ◽  
Vol 170 (10) ◽  
pp. 787-795
Author(s):  
C.H. Lee ◽  
J.H. Cho ◽  
S.J. Park ◽  
J.S. Kim ◽  
Y.K. On ◽  
...  
2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
I A Minciuna ◽  
M Puiu ◽  
G Cismaru ◽  
S Istratoaie ◽  
G Simu ◽  
...  

Abstract INTRODUCTION Catheter ablation is the treatment of choice for patients with recurrent paroxysmal atrial fibrillation (AF) in which antiarrhythmic drug therapy has failed to maintain sinus rhythm. Since its first introduction, intracardiac echocardiography (ICE) has proved to increase the efficacy and reduce complications in AF catheter ablation. One of the main advantages of ICE in the electrophysiology laboratory is the reduction of radiation exposure, for both the patient and the physician. Multiple recent studies have shown the feasibility and safety of zero or near-zero fluoroscopy AF ablation, including transseptal puncture, and outlined the importance of using ICE under the support of 3D mapping systems in reducing radiation exposure. PURPOSE The aim of this study was to show whether the use of ICE reduced the radiation exposure and total procedure time in recurrent paroxysmal AF patients undergoing radiofrequency catheter ablation. METHODS Forty patients that undergone radiofrequency catheter ablation for recurrent paroxysmal AF between January 2018 and May 2019 were included. They were divided in two groups: Group 1 – 20 patients in which ICE was performed and Group 2 – 20 patients in which ablation was performed without ICE guidance. We compared the total ablation time and fluoroscopy dose and time between the two groups. The total ablation time was defined as the time from the groin puncture until the withdrawal of all catheters. RESULTS Among the 40 patients included, 28 were men (70%) and the mean age was 57 years old. The mean procedure time was similar between the two groups (175 ± 52.0 for group 1 and 193 ± 49.9 for group 2, p = 0.33). The difference between the two groups was observed in fluoroscopy dose (9914.13 ± 5018.14 vs. 14561.43 ± 7446.1, p = 0.02) and time (26.04 ± 12.5 vs. 40.52 ± 12.6, p = 0.001). We found that in both groups higher fluoroscopy dose was correlated with higher fluoroscopy time (R = 0.74, p = 0.0001 vs. R = 0.57, p = 0.008) and higher total procedure time (R = 0.63, p = 0.002 vs. R = 0.46, p = 0.03). Furthermore, there was also a correlation between higher fluoroscopy dose and time (R = 0.59, p = 0.005 vs. R = 0.58, p = 0.006). No severe procedure-related complications were recorded. CONCLUSIONS This study shows that the use of ICE for recurrent paroxysmal AF catheter ablation reduces radiation exposure by lowering the fluoroscopy dose and the time of exposure. As a result, by increasing the training and learning curve in low-experienced centers it may finally get us closer to the ideal zero or near-zero fluoroscopy ablation. Abstract P338 Figure. ICE-guided transseptal puncture


2020 ◽  
Vol 4 (53) ◽  
pp. 25-27
Author(s):  
Elżbieta Gadula-Gacek

The paper comments an attempt of investigators of a multicenter, prospective observational trial to assess patient and staff radiation exposure during cardiac device implantations and define dose reference levels for such procedures.


1995 ◽  
Vol 82 (4) ◽  
pp. 884-887. ◽  
Author(s):  
J. Lavoie ◽  
E. P. Walsh ◽  
F. A. Burrows ◽  
P. Laussen ◽  
J. A. Lulu ◽  
...  

Background To determine suitability for ablation procedures in children, two commonly used anesthetic agents were studied: propofol and isoflurane. Methods Twenty patients presenting for a radiofrequency catheter ablation procedure were included and randomly assigned to two groups. A baseline electrophysiology study was performed during anesthesia with thiopental, alfentanil, nitrous oxide, and pancuronium in all patients. At the completion of the baseline electrophysiology study (EPS), 0.8-1.2% isoflurane was administered to patients in group 1 and 2 mg/kg propofol bolus plus an infusion of 150 micrograms.kg-1.min-1 was administered to patients in group 2. Nitrous oxide and pancuronium were used throughout the procedure. After 30 min of equilibration, both groups underwent a repeat EPS. The following parameters were measured during the EPS: cycle length, atrial-His interval, His-ventricle interval, corrected sinus node recovery time, AV node effective refractory period, and atrial effective refractory period. Using paired t tests, the electrophysiologic parameters described above measured during propofol or isoflurane anesthesia were compared to those measured during baseline anesthesia. Statistical significance was accepted as P < 0.05. Results There was no statistically significant difference in the results obtained during baseline anesthesia when compared with those measured during propofol or isoflurane anesthesia. Conclusions Neither propofol nor isoflurane anesthesia alter sinoatrial or atrioventricular node function in pediatric patients undergoing radiofrequency catheter ablation, compared to values obtained during baseline anesthesia with alfentanil and midazolam.


2015 ◽  
Vol 42 (2) ◽  
pp. 152-154 ◽  
Author(s):  
Ajay Sundara Raman ◽  
Saumya Sharma ◽  
Ramesh Hariharan

Electrophysiologic procedures in the young engender concern about the potential long-term effects of radiation exposure. This concern is manifold if such procedures are contemplated during pregnancy. Catheter ablations in pregnancy are indicated only in the presence of an unstable tachycardia that cannot be controlled by antiarrhythmic agents. This report describes the case of an 18-year-old pregnant woman and our stratagem to minimize irradiation of the mother and the fetus.


1998 ◽  
Vol 82 (4) ◽  
pp. 451-458 ◽  
Author(s):  
Lawrence S. Rosenthal ◽  
Mahadevappa Mahesh ◽  
Thomas J. Beck ◽  
J.Phillip Saul ◽  
John M. Miller ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document