INFRARED NANOSECOND LASER ABLATION OF SILICON: THE SPATIAL MULTI-PULSE ENHANCEMENT EFFECT AND ITS DEPENDENCE ON LASER PULSE DURATION – TECHNICAL COMMUNICATION

2009 ◽  
Vol 13 (3) ◽  
pp. 427-436
Author(s):  
Yibo Gao ◽  
Benxin Wu ◽  
Yun Zhou ◽  
Sha Tao
2015 ◽  
Vol 49 (3) ◽  
pp. 035301 ◽  
Author(s):  
Angela De Bonis ◽  
Agostino Galasso ◽  
Antonio Santagata ◽  
Roberto Teghil

2010 ◽  
Vol 108 (11) ◽  
pp. 114514 ◽  
Author(s):  
Sonja Hermann ◽  
Tara Dezhdar ◽  
Nils-Peter Harder ◽  
Rolf Brendel ◽  
Michael Seibt ◽  
...  

2010 ◽  
Vol 53 (6) ◽  
pp. 849-852
Author(s):  
G. M. Mikheev ◽  
V. V. Vanyukov ◽  
T. N. Mogileva ◽  
A. V. Okotrub

2021 ◽  
pp. 251659842110081
Author(s):  
Sooraj Shiby ◽  
Nilesh J Vasa ◽  
Matsuo Shigeki

Pulsed laser-based material removal is a preferred technique for microscribing of copper (Cu) film coated on polymers, as the pulse width limits the heat diffusion. However, experimental studies have shown that microscribing of Cu in air results in recast/redeposit formation and oxidation. Although the water medium can reduce these effects to a certain extent, the material removal rate is lesser for Cu. This article reports the influence of laser pulse duration on a hybrid method to enhance the pulsed laser-assisted microscribing of a copper thin film in the presence of an environmentally friendly sodium chloride salt solution (NaCl). The focused laser beam irradiation of Cu film results in ablation with a temperature of the zone well above the boiling point of Cu, which in turn, can assist in accelerating the chemical reaction. In this hybrid scribing technique, along with laser-based material removal, laser-activated chemical etching also helps in removing the material selectively. A sub-nanosecond laser with a pulse width of 500 ps (picosecond [ps] laser) and a nanosecond laser with a pulse width of 6 ns (nanosecond [ns] laser), with a wavelength of 532 nm, are used to understand the influence of laser pulse duration on this hybrid material removal mechanism. Hybrid microscribing with the ps- and ns lasers in salt solution resulted in an increase in the channel depth by ≈5 µm and ≈9 µm, respectively, compared to the channel depth obtained in deionized water. The theoretical model shows that during the ns laser ablation, the cooling rate is slower, resulting in a high temperature in the ablation zone for a longer duration and improved material removal.


2010 ◽  
Vol 256 (7) ◽  
pp. 2092-2096 ◽  
Author(s):  
Ziyi Fu ◽  
Benxin Wu ◽  
Yibo Gao ◽  
Yun Zhou ◽  
Chengjiao Yu

1983 ◽  
Vol 44 (11) ◽  
pp. 1247-1255 ◽  
Author(s):  
A. L'Huillier ◽  
L.A. Lompre ◽  
G. Mainfray ◽  
C. Manus

2021 ◽  
Vol 138 ◽  
pp. 106916
Author(s):  
M. Curcio ◽  
A. De Bonis ◽  
A. Santagata ◽  
A. Galasso ◽  
R. Teghil

Sign in / Sign up

Export Citation Format

Share Document