Nonlinear contact resonance spectroscopy in atomic force microscopy

2007 ◽  
Vol 40 (22) ◽  
pp. 7136-7145 ◽  
Author(s):  
Daniel Rupp ◽  
Ute Rabe ◽  
Sigrun Hirsekorn ◽  
Walter Arnold
2018 ◽  
Vol 9 ◽  
pp. 945-952 ◽  
Author(s):  
Christopher C Glover ◽  
Jason P Killgore ◽  
Ryan C Tung

This work presents data confirming the existence of a scan speed related phenomenon in contact-mode atomic force microscopy (AFM). Specifically, contact-resonance spectroscopy is used to interrogate this phenomenon. Above a critical scan speed, a monotonic decrease in the recorded contact-resonance frequency is observed with increasing scan speed. Proper characterization and understanding of this phenomenon is necessary to conduct accurate quantitative imaging using contact-resonance AFM, and other contact-mode AFM techniques, at higher scan speeds. A squeeze film hydrodynamic theory is proposed to explain this phenomenon, and model predictions are compared against the experimental data.


Materials ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 2348 ◽  
Author(s):  
Katrin Niegelhell ◽  
Thomas Ganner ◽  
Harald Plank ◽  
Evelyn Jantscher-Krenn ◽  
Stefan Spirk

Lectins are a diverse class of carbohydrate binding proteins with pivotal roles in cell communication and signaling in many (patho)physiologic processes in the human body, making them promising targets in drug development, for instance, in cancer or infectious diseases. Other applications of lectins employ their ability to recognize specific glycan epitopes in biosensors and glycan microarrays. While a lot of research has focused on lectin interaction with specific carbohydrates, the interaction potential of lectins with different types of surfaces has not been addressed extensively. Here, we screen the interaction of two specific plant lectins, Concanavalin A and Ulex Europaeus Agglutinin-I with different nanoscopic thin films. As a control, the same experiments were performed with Bovine Serum Albumin, a widely used marker for non-specific protein adsorption. In order to test the preferred type of interaction during adsorption, hydrophobic, hydrophilic and charged polymer films were explored, such as polystyrene, cellulose, N,-N,-N-trimethylchitosan chloride and gold, and characterized in terms of wettability, surface free energy, zeta potential and morphology. Atomic force microscopy images of surfaces after protein adsorption correlated very well with the observed mass of adsorbed protein. Surface plasmon resonance spectroscopy studies revealed low adsorbed amounts and slow kinetics for all of the investigated proteins for hydrophilic surfaces, making those resistant to non-specific interactions. As a consequence, they may serve as favorable supports for biosensors, since the use of blocking agents is not necessary.


2018 ◽  
Vol 113 (8) ◽  
pp. 083102
Author(s):  
C. Ma ◽  
V. Pfahl ◽  
Z. Wang ◽  
Y. Chen ◽  
J. Chu ◽  
...  

2018 ◽  
Vol 124 (1) ◽  
pp. 014503 ◽  
Author(s):  
Matteo Aureli ◽  
Syed N. Ahsan ◽  
Rafiul H. Shihab ◽  
Ryan C. Tung

Author(s):  
Matteo Aureli ◽  
Ryan Tung

Abstract In this paper, we present a new contact resonance atomic force microscopy based method utilizing a square, plate-like microsensor to accurately estimate viscoelastic sample properties. A theoretical derivation, based on Rayleigh-Ritz method and on an “unconventional” generalized eigenvalue problem, is presented and a numerical experiment is devised to verify the method. We present an updated sensitivity criterion that allows users, given a set of measured in-contact eigenfrequencies and modal damping ratios, to select the best eigenfrequency for accurate data estimation. The verification results are then presented and discussed. Results show that the proposed method performs extremely well in the identification of viscoelastic properties over broad ranges of non-dimensional sample stiffness and damping values.


2019 ◽  
Vol 10 ◽  
pp. 1636-1647 ◽  
Author(s):  
Wenting Wang ◽  
Chengfu Ma ◽  
Yuhang Chen ◽  
Lei Zheng ◽  
Huarong Liu ◽  
...  

Subsurface imaging of Au circuit structures embedded in poly(methyl methacrylate) (PMMA) thin films with a cover thickness ranging from 52 to 653 nm was carried out by using contact resonance atomic force microscopy (CR-AFM). The mechanical difference of the embedded metal layer leads to an obvious CR-AFM frequency shift and therefore its unambiguous differentiation from the polymer matrix. The contact stiffness contrast, determined from the tracked frequency images, was employed for quantitative evaluation. The influence of various parameter settings and sample properties was systematically investigated by combining experimental results with theoretical analysis from finite element simulations. The results show that imaging with a softer cantilever and a lower eigenmode will improve the subsurface contrast. The experimental results and theoretical calculations provide a guide to optimizing parameter settings for the nondestructive diagnosis of flexible circuits. Defect detection of the embedded circuit pattern was also carried out, which indicates the capability of imaging tiny subsurface structures smaller than 100 nm by using CR-AFM.


2020 ◽  
Vol 117 (2) ◽  
pp. 023103
Author(s):  
Wenting Wang ◽  
Chengfu Ma ◽  
Yuhang Chen

Sign in / Sign up

Export Citation Format

Share Document