Micro Extrinsic Fiber-Optic Fabry-Perot Interferometric Sensor Based on Erbium- and Boron-Doped Fibers

2010 ◽  
Vol 27 (2) ◽  
pp. 024208 ◽  
Author(s):  
Rao Yun-Jiang ◽  
Xu Bing ◽  
Ran Zeng-Ling ◽  
Gong Yuan
Materials ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2124 ◽  
Author(s):  
Monika Kosowska ◽  
Daria Majchrowicz ◽  
Kamatchi J. Sankaran ◽  
Mateusz Ficek ◽  
Ken Haenen ◽  
...  

This paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition system. The measurements of refractive indices of liquids were carried out in the range of 1.3 to 1.6. The results of initial investigations show that doped NCD films can be successfully used in fiber-optic sensors of refractive index providing linear work characteristics. Their application can prolong the lifespan of the measurement head and open the way to measure biomedical samples and aggressive chemicals.


Sensors ◽  
2021 ◽  
Vol 21 (19) ◽  
pp. 6609
Author(s):  
Peng Zhang ◽  
Ying Wang ◽  
Yuru Chen ◽  
Xiaohua Lei ◽  
Yi Qi ◽  
...  

A fast real-time demodulation method based on the coarsely sampled spectrum is proposed for transient signals of fiber optic extrinsic Fabry-Perot interferometers (EFPI) sensors. The feasibility of phase demodulation using a coarse spectrum is theoretically analyzed. Based on the coarse spectrum, fast Fourier transform (FFT) algorithm is used to roughly estimate the cavity length. According to the rough estimation, the maximum likelihood estimation (MLE) algorithm is applied to calculate the cavity length accurately. The dense wavelength division multiplexer (DWDM) is used to split the broadband spectrum into the coarse spectrum, and the high-speed synchronous ADC collects the spectrum. The experimental results show that the system can achieve a real-time dynamic demodulation speed of 50 kHz, a static measurement root mean square error (RMSE) of 0.184 nm, and a maximum absolute and relative error distribution of 15 nm and 0.005% of the measurement cavity length compared with optical spectrum analyzers (OSA).


Author(s):  
Na Chen ◽  
Ping Xu ◽  
Fufei Pang ◽  
Tingyun Wang ◽  
Xianglong Zeng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document