scholarly journals Design and Research of the Automatic Hydraulic Testing and Testing Device for Gas Cylinder

2021 ◽  
Vol 1744 (2) ◽  
pp. 022075
Author(s):  
Wei Huang ◽  
Zhou Zhou
2013 ◽  
Vol 331 ◽  
pp. 3-6
Author(s):  
Fei Chen ◽  
Ying Juan Yue ◽  
Xiao Jun Du

In this paper, a testing device for gas cylinder, which is composed of PC, data acquisition card on USB bus technology and the application software compiled on the labVIEW platform, is designed on the basis of virtual instrument technology. The assembly and disassembly of the cylinder plug, weighing, temperature measuring, being irrigated upright, and hydraulic pressure testing are all realized. This device has been put into use with highly practical effect.


1997 ◽  
Vol 78 (02) ◽  
pp. 855-858 ◽  
Author(s):  
Armando Tripodi ◽  
Veena Chantarangkul ◽  
Marigrazia Clerici ◽  
Barbara Negri ◽  
Pier Mannuccio Mannucci

SummaryA key issue for the reliable use of new devices for the laboratory control of oral anticoagulant therapy with the INR is their conformity to the calibration model. In the past, their adequacy has mostly been assessed empirically without reference to the calibration model and the use of International Reference Preparations (IRP) for thromboplastin. In this study we reviewed the requirements to be fulfilled and applied them to the calibration of a new near-patient testing device (TAS, Cardiovascular Diagnostics) which uses thromboplastin-containing test cards for determination of the INR. On each of 10 working days citrat- ed whole blood and plasma samples were obtained from 2 healthy subjects and 6 patients on oral anticoagulants. PT testing on whole blood and plasma was done with the TAS and parallel testing for plasma by the manual technique with the IRP CRM 149S. Conformity to the calibration model was judged satisfactory if the following requirements were met: (i) there was a linear relationship between paired log-PTs (TAS vs CRM 149S); (ii) the regression line drawn through patients data points, passed through those of normals; (iii) the precision of the calibration expressed as the CV of the slope was <3%. A good linear relationship was observed for calibration plots for plasma and whole blood (r = 0.98). Regression lines drawn through patients data points, passed through those of normals. The CVs of the slope were in both cases 2.2% and the ISIs were 0.965 and 1.000 for whole blood and plasma. In conclusion, our study shows that near-patient testing devices can be considered reliable tools to measure INR in patients on oral anticoagulants and provides guidelines for their evaluation.


The intensification of the work of open gutter by applying textured shells to their bottom surface, forming an artificial roughness, is considered. It is shown that the presence of corrugated surfaces contributes to vortex formation during water flow and improves the separation and transportation of mineral impurities previously dropped into the bottom of the gutters. The implementation of operations to improve the structure of the gutters is possible during the repair and restoration works with the use of modern polymer materials. The design of a small-sized hydraulic stand, which makes it possible to study the transport capacity of flows containing solid inclusions, is presented. The method of research is hydraulic testing, accompanied by the use of chiaroscuro effect, as well as photo and film equipment. The optimal structure of the inner surface of the gutters and pipes providing vortex formation, which will improve the ability of the flow to carry out and transport foreign dispersed inclusions (sand) of different granulometric compositions, is determined.


Sign in / Sign up

Export Citation Format

Share Document