Modyflow - A Modular Dynamic Flow Testing Device for Research and TAVI Evaluation

2016 ◽  
Vol 64 (S 01) ◽  
Author(s):  
F. König ◽  
C. Hagl ◽  
N. Thierfelder
Keyword(s):  
1997 ◽  
Vol 78 (02) ◽  
pp. 855-858 ◽  
Author(s):  
Armando Tripodi ◽  
Veena Chantarangkul ◽  
Marigrazia Clerici ◽  
Barbara Negri ◽  
Pier Mannuccio Mannucci

SummaryA key issue for the reliable use of new devices for the laboratory control of oral anticoagulant therapy with the INR is their conformity to the calibration model. In the past, their adequacy has mostly been assessed empirically without reference to the calibration model and the use of International Reference Preparations (IRP) for thromboplastin. In this study we reviewed the requirements to be fulfilled and applied them to the calibration of a new near-patient testing device (TAS, Cardiovascular Diagnostics) which uses thromboplastin-containing test cards for determination of the INR. On each of 10 working days citrat- ed whole blood and plasma samples were obtained from 2 healthy subjects and 6 patients on oral anticoagulants. PT testing on whole blood and plasma was done with the TAS and parallel testing for plasma by the manual technique with the IRP CRM 149S. Conformity to the calibration model was judged satisfactory if the following requirements were met: (i) there was a linear relationship between paired log-PTs (TAS vs CRM 149S); (ii) the regression line drawn through patients data points, passed through those of normals; (iii) the precision of the calibration expressed as the CV of the slope was <3%. A good linear relationship was observed for calibration plots for plasma and whole blood (r = 0.98). Regression lines drawn through patients data points, passed through those of normals. The CVs of the slope were in both cases 2.2% and the ISIs were 0.965 and 1.000 for whole blood and plasma. In conclusion, our study shows that near-patient testing devices can be considered reliable tools to measure INR in patients on oral anticoagulants and provides guidelines for their evaluation.


2016 ◽  
Author(s):  
Hassan Karimi ◽  
Erni Dharma Putra ◽  
Kapil Kumar Thakur ◽  
Rahel Yusuf ◽  
Azwan Shaharun ◽  
...  

Author(s):  
Ana Marta Souza ◽  
Antônio César Valadares de Oliveira ◽  
Enrico Temporim Ribeiro ◽  
Francisco Souza ◽  
Marcelo Colombo Chiari

Tellus B ◽  
2006 ◽  
Vol 58 (4) ◽  
Author(s):  
Emily Lane ◽  
Synte Peacock ◽  
Juan M. Restrepo

Author(s):  
Sagar Chhetri ◽  
Abeer Alsadoon ◽  
Thair Al‐Dala'in ◽  
P. W. C. Prasad ◽  
Tarik A. Rashid ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document