scholarly journals Study on Dry-Ice Particle Jet Polishing Process of 316L Stainless Steel Electrode

2021 ◽  
Vol 1748 ◽  
pp. 052057
Author(s):  
Weiying Yang ◽  
Xu Feng ◽  
Yingjie Xing ◽  
Weihao Pan ◽  
Jinlong Song
2011 ◽  
Vol 347-353 ◽  
pp. 3135-3138
Author(s):  
Hong Hua Ge ◽  
Jie Ting Tao ◽  
Xiao Ming Gong ◽  
Cheng Jun Wei ◽  
Xue Min Xu

Abstract: The effect of electromagnetic treatment on corrosion behavior of carbon steel and stainless steel in simulated cooling water was investigated by electrochemical impedance spectroscopy, potentiodynamic polarization techniques and water analysis. It was found that the charge transfer resistance decreased and the corrosion current density increased after electromagnetic treatment for carbon steel electrode, which shows that such treatment promotes corrosion of carbon steel in simulated cooling water. In contrast, the pitting potential of 316L stainless steel electrode rose which revealed that electromagnetic treatment of the experimental water exhibited corrosion inhibition to 316L stainless steel. Reasons for different corrosion behavior of the two metals were discussed.


2018 ◽  
Vol 90 (14) ◽  
pp. 8680-8685 ◽  
Author(s):  
Shimeles Addisu Kitte ◽  
Muhammad Nadeem Zafar ◽  
Yuriy T. Zholudov ◽  
Xiangui Ma ◽  
Anaclet Nsabimana ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-7 ◽  
Author(s):  
Hai V. Le ◽  
Quang T. Le

In this article, we reported the elaboration of a nonenzymatic glucose sensor based on the polyaniline-supported Cu-CuO core-shell structure prepared on the 316L stainless steel electrode by electrochemical methods. In the first step, polyaniline (PANI) film was electrodeposited on the 316L substrate from a solution of 0.1 M aniline and 0.5 M sulfuric acid in absolute ethanol by the cyclic voltammetry (CV) method. In the second step, the copper particles were electrodeposited on the PANI film from CuCl2·2H2O 0.01 M precursor prepared in a KCl 0.1 M solution by the CV method. In the third step, Cu particles were partially oxidized to CuO by the CV method in a NaOH 0.1 M electrolyte to form a Cu-CuO core-shell structure supported on the PANI film. The as-prepared electrode (Cu-CuO/PANI/316L) was used to detect glucose in a NaOH 0.1 M solution. The Cu-CuO/PANI/316L sensor exhibited a linear range of 0.1–5 mM (R2 = 0.995) with a detection limit of 0.1 mM (S/N = 3) and high sensitivity of (25.71 mA·mM−1·cm−2). In addition, no significant interference was observed from sucrose, maltose, lactose, and ascorbic acid. The results showed that the polyaniline-supported Cu-CuO core-shell structure has the potential to be applied as an electrode material for the nonenzymatic glucose sensor.


2012 ◽  
Vol 1395 ◽  
Author(s):  
T. Misu ◽  
K. Koh ◽  
T. Arai

ABSTRACTCVD polycrystalline diamond surfaces were etched using reactive ion etching system with either a conventional stainless steel electrode or MgO sintered ceramic containing electrode. The micro-needle array of high aspect on diamond substrate surfaces obtained with MgO electrode was fabricated by using back-sputtering from MgO electrode. The RMS roughness of diamond substrate surfaces obtained with MgO electrode is higher than those obtained with stainless steel electrode.


Sign in / Sign up

Export Citation Format

Share Document