scholarly journals Automated system based on open resonator for measuring the electrophysical parameters of sheet dielectrics

2021 ◽  
Vol 1989 (1) ◽  
pp. 012020
Author(s):  
N S Kayro ◽  
D D Teterina ◽  
A V Badin ◽  
K V Bilinskii
1974 ◽  
Author(s):  
Peter H. Henry ◽  
Roy A. Turner ◽  
Robert B. Matthie

2020 ◽  
pp. 54-59
Author(s):  
A. A. Yelizarov ◽  
A. A. Skuridin ◽  
E. A. Zakirova

A computer model and the results of a numerical experiment for a sensitive element on a planar mushroom-shaped metamaterial with cells of the “Maltese cross” type are presented. The proposed electrodynamic structure is shown to be applicable for nondestructive testing of geometric and electrophysical parameters of technological media, as well as searching for inhomogeneities in them. Resonant frequency shift and change of the attenuation coefficient value of the structure serve as informative parameters.


2020 ◽  
Vol 6 (2) ◽  
pp. 147-153
Author(s):  
Muhamad Yusup ◽  
Po. Abas Sunarya ◽  
Krisandi Aprilyanto

System The process of counting and storing in a manual water reservoir analysis has a high percentage of error rate compared to an automated system. In a company industry, especially in the WWT (Waste Water Treatment) section, it has several reservoir tanks as stock which are still counted manually. The ultrasonic sensor is placed at the top of the WWT tank in a hanging position. Basically, to measure the volume in a tank only variable height is always changing. So by utilizing the function of the ultrasonic sensor and also the tube volume formula, the stored AIR volume can be monitored in real time based on IoT using the Blynk application. From the sensor, height data is obtained which then the formula is processed by Arduino Wemos and then information is sent to the MySQL database server via the WIFI network.


In automated control systems for technical processes, the conversion of a continuous signal into a digital code and vice versa from a digital code to a continuous (analog) value is widely used. For direct type converters often used the term ADC, the reverse - DAC. The characteristics of the converters often dramatically affect the parameters of the entire automated system. The importance of the correct choice of ADCs and DACs has especially increased recently in connection with the mass introduction of microcontrollers MC. Indeed, in addition to the ADC and DAC, it is necessary to place the processor core in the microcontroller's crystal, I/O interfaces and many other elements necessary for the functioning of the MC. The use of information converters in the construction industry imposes additional requirements on converters: for example, in building monitoring systems, precision ADCs with extremely high accuracy are often required (while performance may be low), in other applications it is necessary to provide the necessary parameters at a high level of industrial interference, etc. This article explores issues related to the rational choice of ADCs and DACs, taking into account current trends in the IT field and the specifics of work in the construction industry. Sigma-Delta converters are noted as the most promising models of direct type converters.


Sign in / Sign up

Export Citation Format

Share Document