scholarly journals Experimental Study on the Integrated Performance of Dust Removal and Water Vapour Recovery in Catalytic Cracking Gas

Author(s):  
An-Lin Liu ◽  
Lv Peng ◽  
Yan-Hong Zhang ◽  
Liang Ma ◽  
Meng-Ya He
2010 ◽  
Vol 29-32 ◽  
pp. 132-137 ◽  
Author(s):  
Xue Jiang Lai ◽  
Rui Li ◽  
Yong Dai ◽  
Su Yi Huang

Flower baffle heat exchanger’s structure and design idea is introduced. Flower baffle heat exchanger has unique support structure. It can both enhance the efficiency of the heat transfer and reduce the pressure drop. Through the experimental study, under the same shell side flow, the heat transfer coefficient K which the distance between two flower baffles is 134mm is higher 3%~9% than the one of which the distances between two flower baffles are 163mm,123mm. The heat transfer coefficient K which the distance between two flower baffles is 147mm is close to the one of which the distances between two flower baffles is 134mm. The shell volume flow V is higher, the incremental quantity of heat transfer coefficient K is more. The integrated performance K/Δp of flower baffle heat exchanger which the distance between two flower baffles is 134mm is higher 3%~9% than the one of which the distances between two flower baffles are 163mm,123mm. Therefore, the best distance between two flower baffles exists between 134mm~147mm this experiment.


2019 ◽  
Vol 62 (4) ◽  
pp. 164-168
Author(s):  
A. S. Lavrova ◽  
V. V. Vasilyev ◽  
V. M. Strakhov

1968 ◽  
Vol 36 (284) ◽  
pp. 1061-1077 ◽  
Author(s):  
Ian Parsons

SummaryVariations in the value of 2θ131 – 2θ13̄1 of two anorthoclase feldspars of compositions Ab95Or5 and Ab90Or10 were investigated by hydrothermal crystallization of gels for long periods in the temperature range 500–950 °C, at water vapour pressures up to 15 000 lb/in.2. The results are compared to those obtained by MacKenzie (1957) for pure albite. It is shown that the variation in 2θ131 – 2θ13̄1 is largely the result of Al-Si order-disorder and that at 700 °C and above the magnitude of the variation in the anorthoclases suggests that the degree of order is like that in albite, but at lower temperatures, particularly below 600 °C, the variation is less, and the anorthoclases are less ordered than albite at the same temperatures. At 600 °C and above the rate of attainment of equilibrium is the same for all three compositions. Below 600 °C Ab95Or5 behaves differently to albite. At low temperatures the equilibrium degree of Al-Si order in mixed Na-K feldspars is a function of composition as well as of temperature of crystallization.


2002 ◽  
Vol 41 (24) ◽  
pp. 6015-6019 ◽  
Author(s):  
Rensheng Deng ◽  
Fei Wei ◽  
Yan Jin ◽  
Qihao Zhang ◽  
Yong Jin

1966 ◽  
Vol 2 (4) ◽  
pp. 223-227
Author(s):  
K. M. Vaisberg ◽  
I. I. Shabalin ◽  
�. A. Kruglov ◽  
M. A. Shmeleva

CORROSION ◽  
2001 ◽  
Vol 57 (11) ◽  
pp. 986-998 ◽  
Author(s):  
H. Yakuwa ◽  
M. Miyasaka ◽  
T. Go ◽  
S. Nakahama ◽  
M. Kawasaki ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document