scholarly journals Application of Building Integrated Photovoltaic in Hot Humid Climate. Case Study: Office Building in Indonesia

Author(s):  
N A Ardiani ◽  
Suhendri ◽  
M D Koerniawan ◽  
D Y N Naimah
2018 ◽  
Vol 34 ◽  
pp. 02053
Author(s):  
Esra’a Sh. Abbaas ◽  
Ala’eddin A. Saif ◽  
MAC Munaaim ◽  
Md. Azree Othuman Mydin

The influence of courtyard on the thermal performance of Development Department office building in University Malaysia Perlis (UniMAP, Pauh Putra campus) is investigated through simulation study for the effect of ventilation on indoor air temperature and relative humidity of the building. The study is carried out using EnergyPlus simulator interface within OpenStudio and SketchUp plug in software to measure both of air temperature and relative humidity hourly on 21 April 2017 as a design day. The results show that the ventilation through the windows facing the courtyard has sufficient effect on reducing the air temperature compared to the ventilation through external windows since natural ventilation is highly effective on driving the indoor warm air out to courtyard. In addition, the relative humidity is reduced due to ventilation since the courtyard has high ability to remove or dilute indoor airborne pollutants coming from indoor sources. This indicates that the presence of courtyard is highly influential on thermal performance of the building.


2012 ◽  
Vol 433-440 ◽  
pp. 1840-1844 ◽  
Author(s):  
Xiao Shan Fang ◽  
Zhen Yu Song

In building design, architects actively utilize all kinds of methods, such as ventilation and sunshade, to adapt to the hot-humid climate ,which is the main way to create a “green building ”.This paper describes the “climate adaptability ”design tactics in the case of the University Library in the Lingnan region——in a hot-humid climate. Furthermore, this paper gives suggestions by describing the advantages and disadvantages of the typical design practice in order to benefit regional architectural study.


2022 ◽  
Vol 23 (1) ◽  
pp. 64-72
Author(s):  
Mohammad Bani Khalid ◽  
Nabil Beithou ◽  
M.A.Sh. Al-Taani ◽  
Artur Andruszkiewicz ◽  
Ali Alahmer ◽  
...  

2020 ◽  
Vol 12 (7) ◽  
pp. 2591
Author(s):  
Jin Wei ◽  
Fangsi Yu ◽  
Haixiu Liang ◽  
Maohui Luo

Due to the different types of courtyards in vertical courtyard system (VCS), their impacts on thermal performance in office buildings may vary. To better understand this issue, this paper investigates the thermal performance impact of three typical vertical courtyards. A field case study was conducted in VCSs during two typical extreme hot days under hot-humid climate conditions. The results show that the vertical courtyards have significant cooling effects under hot-humid climatic conditions. Via testing on linear, integrated, and rooftop courtyard with fusion layout, the fusion one has an obviously positive impact on air temperature reduction (4.3 °C). Compared with the linear and integrated courtyards, the maximum air temperature difference of fusion layout is around 1.6 °C. The thermal radiation environment of the fusion layout was better than that of the other two (linear and integrated). Besides, the surface temperature of the pavements (wood panel) in the vertical courtyards can reach 47 °C, while the vegetation can lower it by 8 °C under the same weather conditions. These findings show that the courtyard with fusion layout is more suitable for extreme hot weather conditions.