scholarly journals Using a Tuned-Inerto-Viscous-Hysteretic-Damper (TIVhD) for vibration suppression in multi-storey building structures

2021 ◽  
Vol 708 (1) ◽  
pp. 012012
Author(s):  
P Deastra ◽  
D J Wagg ◽  
N D Sims
2013 ◽  
Vol 40 (7) ◽  
pp. 655-662
Author(s):  
George K. Georgoussis

Building structures of low or medium height are usually designed with a pseudostatic approach using a base shear much lower than that predicted from an elastic spectrum. Given this shear force, the objective of this paper is to evaluate the effect of the element strength assignment (as determined by several building codes) on the torsional response of inelastic single-storey eccentric structures and to provide guidelines for minimizing this structural behaviour. It is demonstrated that the expected torque about the centre of mass (CM) may be, with equal probability, positive (counterclockwise) or negative (clockwise). This result means that the torsional strength should also be provided in equal terms in both rotational directions, and therefore the base shear and torque (BST) surface of a given system must be symmetrical (or approximately symmetrical). In stiffness-eccentric systems, appropriate BST surfaces may be obtained when a structural design is based on a pair of design eccentricities in a symmetrical order about CM, and this is shown in representative single-storey building models under characteristic ground motions.


2013 ◽  
Vol 19 (6) ◽  
pp. 811-822 ◽  
Author(s):  
Mohammed Jameel ◽  
A. B. M. Saiful Islam ◽  
Mohammed Khaleel ◽  
Aslam Amirahmad

A multi-storey building is habitually modelled as a frame structure which neglects the shear wall/slab openings along with the inclusion of staircases. Furthermore, the structural strength provided by shear walls and slabs is not precisely incorporated. With increasing building height, the effect of lateral loads on a high-rise structure increases substantially. Inclusion of shear walls and slabs with the frame leads to improved lateral stiffness. Besides, their openings may play imperative role in the structural behaviour of such buildings. In this study, 61 multi-storey building configurations have been modelled. Corresponding analyses are performed to cope with the influence of shear walls, slabs, wall openings, masonry walls and staircases in addition to frame modelling. The finite element approach is used in modelling and analysis. Structural responses in each elemental combination are evaluated through equivalent static and free vibration analyses. The assessment reveals that inclusion of only slab components with frame modelling contributes trivial improvement on structural performance. Conversely, the presence of shear wall slabs with frame improves the performance noticeably. Increasing wall openings decreases the structural responses. Furthermore, it is not recommended to model staircases in addition to frame–slab–shear wall modelling, unless the effect of wall openings and slab openings is adequately considered.


Author(s):  
Andres Rodriguez-Torres ◽  
Jesús Morales-Valdez ◽  
Wen Yu

The article deals with the development of active vibration control of seismically-excited building structures. The control scheme is based on an alternative proportional-derived (PD) controller designed based only on the bandwidth of the system, which is an attractive technique for structural vibration suppression purposes and practical motion control solutions. The tuning method is analyzed employing Kharitonov’s theorem and Routh-Hurwitz criteria, which give necessary and sufficient conditions for choosing the two PD range of gains. Based on modal analysis, the system is transformed into a set of decoupled ordinary differential equations to simplify the PD design. An important advantage concerning a classical PD controller is the proposed PD design only uses the natural frequencies, which are relatively easy to estimates around an experimental test. Moreover, the proposed approach does not need frequently tune the gains parameters, so the design procedure is greatly simplified and, the proposed scheme does not need the system parameters, which generally are unknown. This method allows generalizing the controller design for multi-story buildings without modifying the controller structure, by choosing a scalar parameter. The effectiveness of the proposed PD schemes is demonstrated through simulation and experimental results of a reduced scale two-story building prototype.