A SIMPLE APPROXIMATE FORMULATION FOR THE FIRST TWO FREQUENCIES OF ASYMMETRIC WALL–FRAME MULTI-STOREY BUILDING STRUCTURES

2000 ◽  
Vol 236 (1) ◽  
pp. 141-160 ◽  
Author(s):  
Y. WANG ◽  
C. ARNAOUTI ◽  
S. GUO
2013 ◽  
Vol 40 (7) ◽  
pp. 655-662
Author(s):  
George K. Georgoussis

Building structures of low or medium height are usually designed with a pseudostatic approach using a base shear much lower than that predicted from an elastic spectrum. Given this shear force, the objective of this paper is to evaluate the effect of the element strength assignment (as determined by several building codes) on the torsional response of inelastic single-storey eccentric structures and to provide guidelines for minimizing this structural behaviour. It is demonstrated that the expected torque about the centre of mass (CM) may be, with equal probability, positive (counterclockwise) or negative (clockwise). This result means that the torsional strength should also be provided in equal terms in both rotational directions, and therefore the base shear and torque (BST) surface of a given system must be symmetrical (or approximately symmetrical). In stiffness-eccentric systems, appropriate BST surfaces may be obtained when a structural design is based on a pair of design eccentricities in a symmetrical order about CM, and this is shown in representative single-storey building models under characteristic ground motions.


2013 ◽  
Vol 19 (6) ◽  
pp. 811-822 ◽  
Author(s):  
Mohammed Jameel ◽  
A. B. M. Saiful Islam ◽  
Mohammed Khaleel ◽  
Aslam Amirahmad

A multi-storey building is habitually modelled as a frame structure which neglects the shear wall/slab openings along with the inclusion of staircases. Furthermore, the structural strength provided by shear walls and slabs is not precisely incorporated. With increasing building height, the effect of lateral loads on a high-rise structure increases substantially. Inclusion of shear walls and slabs with the frame leads to improved lateral stiffness. Besides, their openings may play imperative role in the structural behaviour of such buildings. In this study, 61 multi-storey building configurations have been modelled. Corresponding analyses are performed to cope with the influence of shear walls, slabs, wall openings, masonry walls and staircases in addition to frame modelling. The finite element approach is used in modelling and analysis. Structural responses in each elemental combination are evaluated through equivalent static and free vibration analyses. The assessment reveals that inclusion of only slab components with frame modelling contributes trivial improvement on structural performance. Conversely, the presence of shear wall slabs with frame improves the performance noticeably. Increasing wall openings decreases the structural responses. Furthermore, it is not recommended to model staircases in addition to frame–slab–shear wall modelling, unless the effect of wall openings and slab openings is adequately considered.


2020 ◽  
Vol 2020 (2) ◽  
pp. 28-34
Author(s):  
Bohdan Demchyna ◽  
◽  
Leonid Vozniuk ◽  

This article is devoted to the problems of the existing residential buildings of 70-80 years of construction of the last century, which have been in operation for about 50 years and are subject to immediate technical inspection. The most important factor for the safe operation of such buildings is the quality of construction, as in this period the construction was performed with many shortcomings that are manifested today. The article describes the problem of joints of loggias with the building in the design and construction of multi-storey buildings with load-bearing brick walls. Poor ligation of bricks in the masonry, as well as the lack of quality ligation of the transverse walls of loggias with load-bearing longitudinal walls of the building leads to the formation of cracks on the entire height of the loggias, which completely cut them at the abutment, which creates an emergency collapse of building structures. A real example of such a problem in the existing 9-storey building with brick load-bearing walls, where the shortcomings of construction were manifested, namely the poor quality of masonry at the junction of loggias to the load-bearing walls of the building. The structural scheme is also described, as well as the main structures of the building. The main damages and defects are shown. Using the PC "LIRA-SAPR" created a calculation model and compared the results of calculations with the existing condition of the considered area of the building. Recommendations for strengthening the emergency section of the building are given.