scholarly journals Dynamic load-bearing capacity analysis for the main Transmission Mechanism of Traction Machine in a Cargo Lift

2021 ◽  
Vol 1043 (3) ◽  
pp. 032040
Author(s):  
Qingchao Liu ◽  
Wenzhi Liu ◽  
Zhiqi Wang
2019 ◽  
Vol 81 (2) ◽  
pp. 240-248
Author(s):  
R. Chmielewski ◽  
L. Kruszka ◽  
L. Muzolf

The paper presents problems related to the load-bearing capacity analysis of the building partitions of the cold storage facility. The subject of the case study are two different buildings built in the early fifties of the last century. Despite the similar cubature and the construction period, the structures of these buildings are different. The analysed cold store in Warsaw (Poland) is a steel and brick structure, while the second example concerns a reinforced concrete slab-pillar structure located in Wloclawek (Poland). In both cases, the issue related to the assessment of the current technical condition of the structural elements, including the safety of the load-bearing structure and the safety of its use was considered. Moreover, the permissible load for inter-storey slabs in both cases was determined. In order to properly determine the current load-bearing capacity of inter-story slabs, the archival technical and operational documentation of buildings was firstly analysed. Their technical condition was also taken into account in the assessment process. In-situ inspections of both buildings had been carried out. This allowed the determination of the scope of necessary tests and the selection of test and check points for each structural element. Such actions allowed to identify cross-sections of the structural elements and the parameters of built-in materials. The performed diagnostics also allowed to properly determine the technical condition of each structural element, the degree of degradation of the structure and to correctly determine its current load-bearing capacity while simultaneously satisfying both limit states - the Ultimate Limit State (ULS) and the Serviceability Limit State (SLS).


2020 ◽  
Vol 62 (1) ◽  
pp. 55-60
Author(s):  
Per Heyser ◽  
Vadim Sartisson ◽  
Gerson Meschut ◽  
Marcel Droß ◽  
Klaus Dröder

2017 ◽  
Vol 68 (1) ◽  
pp. 94-100
Author(s):  
Oana Tanculescu ◽  
Adrian Doloca ◽  
Raluca Maria Vieriu ◽  
Florentina Mocanu ◽  
Gabriela Ifteni ◽  
...  

The load-bearing capacity and fracture pattern of direct inlay-retained FRC FDPs with two different cross-sectional designs of the ponticwere tested. The aim of the study was to evaluate a new fibre disposition. Two types of composites, Filtek Bulk Fill Posterior Restorative and Filtek Z250 (3M/ESPE, St. Paul, MN, USA), and one braided polyethylene fibre, Construct (Kerr, USA) were used. The results of the study suggested that the new tested disposition of the fibres prevented in some extend the delamination of the composite on buccal and facial sides of the pontic and increased the load-bearing capacity of the bridges.


2021 ◽  
Vol 60 (1) ◽  
pp. 503-518
Author(s):  
Juan Han ◽  
Lu Zhu ◽  
Hai Fang ◽  
Jian Wang ◽  
Peng Wu

Abstract This article proposed an innovative composite sandwich structure reinforced with trapezoidal latticed webs with angles of 45°, 60° and 75°. Four specimens were conducted according to quasi-static compression methods to investigate the compressive behavior of the novel composite structures. The experimental results indicated that the specimen with 45° trapezoidal latticed webs showed the most excellent energy absorption ability, which was about 2.5 times of the structures with vertical latticed webs. Compared to the traditional composite sandwich structure, the elastic displacement and ultimate load-bearing capacity of the specimen with 45° trapezoidal latticed webs were increased by 624.1 and 439.8%, respectively. Numerical analysis of the composite sandwich structures was carried out by using a nonlinear explicit finite element (FE) software ANSYS/LS-DYNA. The influence of the thickness of face sheets, lattice webs and foam density on the elastic ultimate load-bearing capacity, the elastic displacement and initial stiffness was analyzed. This innovative composite bumper device for bridge pier protection against ship collision was simulated to verify its performance. The results showed that the peak impact force of the composite anti-collision device with 45° trapezoidal latticed webs would be reduced by 17.3%, and the time duration will be prolonged by about 31.1%.


Sign in / Sign up

Export Citation Format

Share Document