scholarly journals Study on Temperature Characteristics of Frequency -domain Dielectric Spectrum of Capacitive Oil-paper Insulation Bushing Based on Extended Debye Model

Author(s):  
X. W. Xu ◽  
G. Pan ◽  
K. Wang ◽  
W. D. Liu
Energies ◽  
2013 ◽  
Vol 6 (4) ◽  
pp. 2204-2220 ◽  
Author(s):  
Yazid Hadjadj ◽  
Fethi Meghnefi ◽  
Issouf Fofana ◽  
Hassan Ezzaidi

Author(s):  
Zhang Yizhou ◽  
Wang Lei ◽  
Zhao Pengyu ◽  
Wang Liang ◽  
Gao Xuan ◽  
...  

The paper use a new dielectric frequency response method to measure the cable insulation’s complex dielectric spectrum at wide frequency domain. During the experiment, Cross-linked polyolefin insulated cables are accelerate aged under thermal and irradiation environment, and measured with elongation at break, Fourier transform infrared spectrum, oxidation induced temperature, and dielectric spectrum as well, to study the property degradation rule. The result indicate that the thermal ageing mechanism is similar to irradiation ageing, of which is the degradation due to polymer molecular chain unlinking, oxidizing material increase and additives content reduce. This chemical constituent changing in insulation could not result traditional electric property change but could be monitored by dielectric loss spectrum curve among wide frequency domain, which stayed stable but shifted to lower frequency as cable degradation. Finally, the paper discussed the main mechanism of cross-linked polyolefin dielectric property changing while ageing according to the electrophysical characteristic of solid insulation, and provided some suggestions about the non-destructive techniques for nuclear power plant cables using dielectric spectrum.


2013 ◽  
Vol 385-386 ◽  
pp. 1175-1178
Author(s):  
Jun Qiang Zhang ◽  
Tao Zhao ◽  
Yun Peng Liu

Return voltage diagnostic method is an effective method of non-destructive diagnosis in transformer insulating state. The current study is that through experiments get polarization spectrum to analysis the transformer insulating state, but not yet carried out the influence of various factors to the experimental results. So, based on the Debye model and specific parameters comes from one equivalent model of the actual transformer, this paper using RVM methods to simulation analysis maximum return voltage and dominant time constant under different factors. Simulation results show that the diagnostic methods that combine maximum return voltage value with dominant time constant can preferably reflect the transformer insulation state.


Sign in / Sign up

Export Citation Format

Share Document