scholarly journals Effects of blood flow patent and cross-sectional area on hemodynamic into patient-specific cerebral aneurysm via fluid-structure interaction method: A review

Author(s):  
Nurul Najihah Mohd Nazri ◽  
Muhammad Uzair Matalif ◽  
Mohd Azrul Hisham Mohd Adib
2015 ◽  
Vol 138 (1) ◽  
Author(s):  
Shuping Wang ◽  
Jane H. Davidson

A model of the flexible porous manifold that captures the interaction between the flow field and the deformation of the manifold is developed and applied to understand how the fabric manifold works for conditions expected in solar water heaters. Contrary to the widely held hypothesis that the change of cross-sectional area induced by the fluid–structure interaction is beneficial, the numerical results demonstrate the change of cross-sectional area has no significant impact on the effectiveness of the manifold. In comparison to a rigid porous manifold, the performance of the flexible manifold is slightly worse because the collapse of the manifold encourages entrainment. The dimensionless permeability plays a crucial role in determining the performance and can be selected to limit entrainment and release fluid near the vertical level of neutral buoyancy.


Fluids ◽  
2019 ◽  
Vol 4 (3) ◽  
pp. 119 ◽  
Author(s):  
Anvar Gilmanov ◽  
Alexander Barker ◽  
Henryk Stolarski ◽  
Fotis Sotiropoulos

When flow-induced forces are altered at the blood vessel, maladaptive remodeling can occur. One reason such remodeling may occur has to do with the abnormal functioning of the aortic heart valve due to disease, calcification, injury, or an improperly-designed prosthetic valve, which restricts the opening of the valve leaflets and drastically alters the hemodynamics in the ascending aorta. While the specifics underlying the fundamental mechanisms leading to changes in heart valve function may differ from one cause to another, one common and important change is in leaflet stiffness and/or mass. Here, we examine the link between valve stiffness and mass and the hemodynamic environment in aorta by coupling magnetic resonance imaging (MRI) with high-resolution fluid–structure interaction (FSI) computational fluid dynamics to simulate blood flow in a patient-specific model. The thoracic aorta and a native aortic valve were re-constructed in the FSI model from the MRI data and used for the simulations. The effect of valve stiffness and mass is parametrically investigated by varying the thickness (h) of the leaflets (h = 0.6, 2, 4 mm). The FSI simulations were designed to investigate systematically progressively higher levels of valve stiffness by increasing valve thickness and quantifying hemodynamic parameters known to be linked to aortopathy and valve disease. The computed results reveal dramatic differences in all hemodynamic parameters: (1) the geometric orifice area (GOA), (2) the maximum velocity V max of the jet passing through the aortic orifice area, (3) the rate of energy dissipation E ˙ diss ( t ) , (4) the total loss of energy E diss , (5) the kinetic energy of the blood flow E kin ( t ) , and (6) the average magnitude of vorticity Ω a ( t ) , illustrating the change in hemodynamics that occur due to the presence of aortic valve stenosis.


2021 ◽  
pp. 1-18
Author(s):  
Abdulgaphur Athani ◽  
N.N.N. Ghazali ◽  
Irfan Anjum Badruddin ◽  
Sarfaraz Kamangar ◽  
Ali E. Anqi ◽  
...  

BACKGROUND: The blood flow in the human artery has been a subject of sincere interest due to its prime importance linked with human health. The hemodynamic study has revealed an essential aspect of blood flow that eventually proved to be paramount to make a correct decision to treat patients suffering from cardiac disease. OBJECTIVE: The current study aims to elucidate the two-way fluid-structure interaction (FSI) analysis of the blood flow and the effect of stenosis on hemodynamic parameters. METHODS: A patient-specific 3D model of the left coronary artery was constructed based on computed tomography (CT) images. The blood is assumed to be incompressible, homogenous, and behaves as Non-Newtonian, while the artery is considered as a nonlinear elastic, anisotropic, and incompressible material. Pulsatile flow conditions were applied at the boundary. Two-way coupled FSI modeling approach was used between fluid and solid domain. The hemodynamic parameters such as the pressure, velocity streamline, and wall shear stress were analyzed in the fluid domain and the solid domain deformation. RESULTS: The simulated results reveal that pressure drop exists in the vicinity of stenosis and a recirculation region after the stenosis. It was noted that stenosis leads to high wall stress. The results also demonstrate an overestimation of wall shear stress and velocity in the rigid wall CFD model compared to the FSI model.


Sign in / Sign up

Export Citation Format

Share Document